Sunco HB_L2 2 Inch LED Linear High Bay User Manual

June 15, 2024
SUNCO

Sunco HB_L2 2 Inch LED Linear High Bay User Manual
Sunco HB_L2 2 Inch LED Linear High Bay

Whats in the Box?

High Bay

Whats in the Box

Get Your Gear
  • Drill

  • Hammer

  • Pliers

  • Tape Measure

Before You Start

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

  • Turn off circuit breaker before installing this fixture.
  • Suitable for use in wet environments at temperatures ranging from -22° to 122°.
  • Not intended for use with emergency fixtures.
  • Not compatible with photo controls.
  • Not compatible with occupancy sensors.
  • Not compatible with third party sensors.
  • Not compatible with all dimmers. For more dimming information, please visit www.sunco.com.
  • Not compatible with timing devices.
  • All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards.
  • Please review installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.

WARNING:
Cancer & Reproductive Harm- www.P65Warnings.ca.gov

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quick start Guide

Step 1
Attach chains to V hooks
Quick start Guide

Step 2
Insert eye hooks into anchors.
Quick start Guide

Step 3
Attach fixture to ceiling using chain on eye hooks.
Quick start Guide

Step 4
Place wires and cap inside driver box, then secure.
Quick start Guide

Installation Guide

STEP 1

a. Turn off circuit breaker before installation.
b. Hook chain onto 1x V hook. Repeat with second hook and chain.
c. Insert hooks ends into slotted holes, as shown. Repeat with second hook.

STEP 2

a. Attach 2x anchors (not included) to the ceiling. Space the hooks 23.43” (595 mm) apart.
b. Screw eye hooks (not included) into the anchors
Installation Instruction

STEP 3

a. Secure fixture to ceiling by looping chain onto screw eye hooks.
Installation Instruction

STEP 4

a. After the installation, connect the supply wires in terminal cap to fixture wires. Refer to wiring instruction in diagram at left.
b. Ground to Ground (yellow/green); Live to Live (black); Neutral to Neutral (white); Pink and Purple wires connect to dimmer.
Installation Instruction

STEP 5

a. Insert the terminal cap and wires into the driver box. Secure terminal cap.
b. Turn on power and test the light.
Installation Instruction

STEP 6

a. Gray and Purple wires connect to dimmer. Constant current can be achieved by 0-10V dimming. Connect to a compatible dimmer (not included) to the fixture’s dimming signal wires.
b. If you choose not to use the dimming function, cap each dimming wire (not together).
Installation Instruction

Product Details

Recommended Dimmers
Brand Model
LUTRON DVSTV
LUTRON NTSTV-DV
LUTRON DVTV
LEVITON AWSMT-7DW
LEVITON DD710-BDZ
LEVITON DS710-10Z

Scan for the full compatible dimmer list!
QR Code

Specifications
Voltage 120V-277V Average Lifetime 50,000 hrs
Wattage 85W/110W/165W/220W/300W Lumens 12000lm-42000lm
CRI 80+ Temperature -22°F to 122°F
Beam Angle 90° Frequency 50/60HZ
Weight 4.8lbs-6.6lbs Efficacy 140lm/w
Housing Material Sheet Metal Amps 0.9A-3.0A
Dimmable 0-10V Warranty 7 Years

Common Troubleshooting

Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem.

If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.

Installation

Light isn’t turning on.| Double check if fixture is properly connected and circuit breaker hasn’t been tripped.
---|---
Light unexpectedly fails.| For further assistance, contact our customer support.

Dimming

Light not dimming to lowest setting.| Ensure minimum dimmer load requirement is met
---|---
Light not dimming smoothly| Verify dimmer compatibility with fixture
Light not compatible with dimmer switch| Check light-dimmer compatibility. Consider purchasing compatible switch if necessary

Flickering

Light is flickering when turning on.| Check that fixture wiring connections are secure
---|---
Light flickering with other lights on the same circuit| Check that the lights on the same circuit are not overloading the circuit.
Light flickering when turned on| Verify fixture compatibility and that it is grounded.
Light flickering when dimmed.| Verify dimmer switch compatibility.

Buzzing

Fixture buzzing with power outages.| Verify light is connected to surge protector securely.
---|---
Fixture buzzing with appliances or electronic devices| Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc.
Fixture buzzing when dimmed.| Verify dimmer switch compatibility

Light Distribution Angle

Not a lighting nerd? No worries, you can skip this page.
Light Distribution Angle

AVERAGE BEAM ANGLE (50%): 96.1 DEG

C0/180
C90/270

UNIT:cd: Luminous Intensity Distribution 1

Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:

A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.

An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more.

It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.

Customer Support

Warranty Policy

This product is covered by our industry leading 7 year warranty.

It gets even better – scan the QR code for 2 extra years of protection!.

Scan me for two extra years!
QR Code

30 Day Return Policy

At Sunco, we value our customers and stand by the quality and performance of our products.

If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.

Customer Service

Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:

Email: support@sunco.com
Call   or Text: 844-334-9938

Lighting made better.

support@sunco.com
844-334-9938

Sunco Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals