Before Using
Before using the XTI product, please follow these guidelines:

  1. Place the product on a firm and smooth surface, avoiding vibrations.
  2. Level the balance using the bubble level.
  3. Use an independent power source to avoid electrical disturbances.
  4. Do not place any objects on the platter when turning on the balance
  5. Turn on the balance 2-3 minutes before using.
  6. Avoid large temperature changes and sites with strong airflow.
  7. Do not overload the balance, staying within the maximal capacity.

Power
The XTI product requires the following power specifications:

  • Input: 120~240V
  • Output: 12V/1A, 6V/4Ah

System Power Consumption
The XTI product has the following power consumption:

  • Approximately 12mA
  • Approximately 36mA
  • Battery Life: 320 hours

Low Power Warning
The XTI product will provide a warning when the battery is low.

Displays and Keyboard Description
The XTI product features a display and keyboard for operation.

Basic Functions
The XTI product has various basic functions for user convenience.

Parameters
The XTI product has parameters that can be adjusted for customization.

Error Messages
The XTI product may display error messages for troubleshooting purposes.

Warranty
The XTI product comes with a warranty for customer protection.

Frequently Asked Questions (FAQ)

How do I level the balance using the bubble level?
Place the balance on a firm and smooth surface, then adjust the balance until the bubble is centred at the bubble level.

What should I do if the battery is low?
When the battery is low, please replace it with a new one to ensure the proper functioning of the XTI product.

How long does the battery last?
The battery of the XTI product lasts approximately 320 hours.

What should I do if I encounter error messages?
If you encounter error messages on the XTI product, please refer to the user manual for troubleshooting steps or contact customer support for assistance.

BEFORE USING

  • Place this product in a firm and smooth place, don’t place it in vibration or shaking, use a bench for use on four only adjust your foot, and adjust the balance using the bubble level.
  • Use independent sources, and avoid other electrical disturbances.
  • Don’t put any object on the platter when turning on the balance.
  • Please, turn on 2-3 minutes before using.
  • Avoid temperature changes too large and airflow strenuous sites.
  • Don’t overload the balance, don’t exceed the maximal capacity.

SPECIFICATIONS

XTI

  • Accuracy Clase III
  • Loadcell sensitivity range 1.5 ~ 3.0mV/V
  • Nonlinear ≤0.01%F.S
  • System working voltage DC:5V
  • Division 2/5-5/10
  • Large LCD connector Sampling serial output way
  • Sample rate 20 times per second (can select)
  • Internal resolution 300000~600000

POWER

  • Input 120~240V
  • Output 12V/1A
  • Rechargeable battery 6V/4Ah

SYSTEM POWER CONSUMPTION

  • Main system power consumption is about 12mA
  • Main system power consumption (with backlight) is about 36mA
  • Battery life, no backlight about 320 hours

LOW POWER WARNING

  • When the battery voltage is below 5.6V, the low power indicator on the LCD will light up.
  • When the battery voltage is below 5.5V, the low power indicator on the LCD will start to flash.
  • When the battery voltage is below 5.4V, the scale will turn off.

**DISPLAYS AND KEYBOARD DESCRIPTION

**

GIROPES-XTI-Retail-Scale-FIG- \(1\) GIROPES-XTI-
Retail-Scale-FIG- \(2\)

NOTE : No description keys have a function on this device.

BASIC FUNCTIONS

  • TARE FUNCTION
    Place a container on the pan and press the key, the weight of the container will be deducted. After a tare, you will be able to weigh any object as its net weight.

  • PRICE LOOK UP (PLU)
    Press the key to select between PLU group 1 (P01 – P20) and PLU group 2 (P21 – P40). The display will light up the group selected.

  • SAVE THE PRICE LOOK UP (PLU)
    Enter the desired unit price and press the key, then press one of the 20 PLU memories (P1 – P20), the unit price will be saved in the appointed number. To change the saved unit price, just repeat the same steps.

  • PAYMENT CHANGE
    Press the key , and enter the payment amount, the scale will automatically calculate the customer charge.

Example : If the total price is 15 Euro, press this key and enter 20 Euro, on the Unit Price window will be displayed 5 Euro as the change for the customer.

**PARAMETERS

**

PARAMETERS SETTING

The scale has three menus:

GIROPES-XTI-Retail-Scale-FIG- \(7\)

PARAMETERS SCHEME

GIROPES-XTI-Retail-Scale-FIG- \(8\)


UF1

| ****

bLit

| ****

Key 0

| ****

To turn off the screen backlight.

---|---|---|---
Key 1| Select automatic screen backlight.






UF2

| ****





rS232

| Key 0| None – Without selecting any protocol.
Key 1| TPU_A – to select the TPV0 type A protocol.
Key 2| TPU_b – to select the TPV0 type B protocol.
Key 3| TPU_2A – to select the TPV-2A protocol.
Key 4| TPU_2B – to select the TPV-2B protocol.
Key 5| TPU_4 – to select the TPV-4 (Berkel) protocol.
Key 6| TPU_7 – to select the TPV-7 protocol (Samsung).
Key 7| TEdC1 – to select the TED-C1 (CAS) protocol.
Key 8| tiSA_A – to select the TISA-A protocol.
Key 9| tiSA_S – to select the TISA-S protocol.
Keys 1+0| Toledo – to select the Toledo protocol.
Keys 1+1| nCiECr – to select the NCI-ECR protocol.
| | Keys 1+2| nCiGEn – to select the NCI-General protocol.


UF3

| bAUd| ****

Keys 0 to 4

| ****

With the 0 to 4 keys we will select the Baud: 1200, 2400,

4800, 9600 and 19200 respectively.




UF4

| ****



ModE

| ****



Keys 0 to 3

| ****

With the keys 0 to 3 we will select the sending mode of the TPV0 protocol: TrAn0 (At the request of the PC), TrAn1C (Continuous Frame-A Mode), TrAn1M (Continuous Frame-B Mode) and TrAn2 (Manual Mode) respectively.

The rest of the protocols always work upon request as detailed in the corresponding document.

TO GO FROM A “UF” MENU TO ANOTHER, THE KEYS OF AND WE WILL SERVE TO MOVE TOWARDS THE LEFT OR RIGHT RESPECTIVELY.

ERROR MESSAGES

WARRANTY

This scale is warranted against defects of manufacturing and materials for 1 year, from the delivery date. During this period, GIROPÈS SL will take charge of repairing the scale. This warranty does not cover defects or damage caused by misuse, overloading or improper installation contrary to the recommendations described in this manual. This warranty does not cover shipping costs for the reparation of the balance.