Yale YRD620 Wi-Fi Touchscreen Smart Lock Instruction Manual
- June 14, 2024
- Yale
Table of Contents
Yale YRD620 Wi-Fi Touchscreen Smart Lock
Product Information
Specifications
- Model : YRD226/YRD426
- Optional Network Module
- Supported Network Modules: Z-Wave Plus, ZigBee, iM1
- Max User Codes: 250 with Z-Wave Plus or ZigBee network module, 25 without network module or with iM1 network module, 12 withBluetooth
Product Usage Instructions
Installation
- Download the BILT App for step-by-step installation instructions and product registration.
- Prepare the door by following the instructions provided.
- Install the latch and strike plate in either the 2-3/8 position or the 2-3/4 position.
- Install the touchscreen escutcheon on the inside and outside of the door.
- Install the interior mounting plate by loosening the screw to remove the cover.
- Attach the cable assembly.
- Install the interior escutcheon.
- Test the operation of the lock by ensuring the bolt is in the retracted (unlocked) position before installing batteries.
- Install optional network module if desired.
- Install batteries and cover by tightening the screw.
Programming
Note : Before programming, a Master PIN Code must be created.
- Create a Master PIN Code upon installation or after resetting the lock to factory default. This step is necessary before anyfurther programming.
- Create User PIN Codes using the Master PIN Code. The maximum number of user codes depends on the network module being used.
- To unlock the door using a PIN Code, enter the PIN Code on the keypad.
Touchscreen Deadbolt Installation and Programming Instructions
(YRD226/YRD426)
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY
Preparing Door
Optional Fire Kit Parts
For Model YRD620 ONLY
Installing Optional Fire Cup
-
Installing Latch & Strike Plate
-
Installing Touchscreen Escutcheon
-
Installing Interior Mounting Plate
-
Attaching the Cable Assembly
-
Installing Interior Escutcheon
Testing Operation -
Installing Optional Network Module
-
Installing Batteries & Cover
Congratulations, you’ve installed the Yale® Assure Lock® Touchscreen Deadbolt (YRD226/YRD426)! Continue with Programming Instructions to customize your product.
Programming Instructions **
**
Lock Activation
- Master PIN Code must be created before any further programming.
- Max User Codes = 250 with Z-Wave Plus or ZigBee network module
- Max User Codes = 25 without network module or with iM1 network module
- Nax User Codes = 12 with Bluetooth
Creating Master PIN Code
Creating a Master PIN Code must be performed upon installation or after
resetting the lock to factory default. Programming and use of lock is not
possible until this step has been successfully completed.
Creating User PIN Codes
- Master PIN code must be created first.
- *Max user codes = 250 with Z-Wave Plus or ZigBee network module
- Max user codes = 25 without network module or with iM1 network module
- Max user codes = 12 with Bluetooth
Unlocking Door with PIN Code
Code Chart Duplicate
if necessary
PIN Code Management (With Network Module – Up to 250 Users)
User Type| User Name| User #| PIN Code
Master| | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User | | |
User __| | |
Resetting Lock to Factory Default
Interior Escutcheon
When lock is reset to factory defaults all user codes (including the Master
PIN code*) are deleted and all programming features are reset to original
default settings (see below).
- Remove the battery cover and batteries.
- Remove the interior escutcheon to access the reset button.
- The reset button (see image at right) is located beside the PCB cable connector.
- While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button.
- Replace battery cover.
Upon reset, Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.
Factory Settings
Settings | Factory Setting |
---|---|
Master PIN Code | Registration *_required_** |
Automatic Re-lock | Disabled |
Automatic Re-lock Time | 30 Seconds |
Escape Return Mode (Model YRD620 only) | Disabled |
Inside Indicator Light | Disabled (Off) |
Language Setting | English |
Lockout Mode | Disabled |
One Touch Locking | Enabled |
Privacy Setting | Disabled |
Shutdown Time | 60 Seconds |
Volume Setting | Enabled (Low) |
Wrong Code Entry Limit | 5 Times |
*The Master PIN code must be registered prior to any other programming of the lock.
Definitions
All Code Lockout Mode:
This feature is enabled by the Master code. When enabled, it restricts all
user (except Master) PIN code access. When attempting to enter a code while
the unit is in Lockout, the RED locked padlock will appear on the screen.
Automatic Re-lock Time:
After a successful code entry or manual unlock with the key, the lock will
automatically re-lock after each unlock in an effort to keep your home secure.
This feature is optional, and can be turned off. In the ON mode, the lock will
automatically re-lock after thirty (30) seconds.
Inside Indicator Light:
Located on the interior escutcheon. Shows active status (Locked) of lock and
can be enabled or disabled in the Advanced Lock Settings (Main Menu selection
3).
Language Setting Mode:
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting
for the lock’s voice prompts.
Low Battery:
When battery power is low, the Low Battery Warning indicator flashes RED. If
battery power is completely lost, use the cylinder key override.
Master PIN Code:
The Master PIN code is used for programming and for feature settings. It must
be created prior to programming the lock. The Master code will also operate
(unlock/lock) the lock.
Network Module Setting:
With the optional Network Module installed, this setting becomes available
thru the Main Menu (7) and allows the lock to connect with a network
controller.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the latch
(during Automatic Re-lock duration or when Automatic Re-lock is disabled).
When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-
lock the lock.
Previous:
While in Menu Mode, pressing this icon cancels the current operation and
returns the user to the previous step.
Privacy Mode:
Privacy mode is disabled by default. Enable Privacy Mode by pressing the
privacy button for 4 seconds to put the lock in do-not-disturb mode (all pin
codes are disabled).
Shutdown Time:
The unit will shutdown (flashing RED) for sixty (60) seconds and not allow
operation after the wrong code entry limit (5 attempts) has been met.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code:
The user code operates the lock. The maximum number of user codes with Z-Wave
Plus or ZigBee network module is 250; without network module or with iM1
network module, maximum is 25; with Bluetooth, maximum is 12. Note: When
deleting user pin code(s), screen will display user pin code being deleted.
Volume Setting Mode:
The volume setting for PIN code verification is set to Low (2) by default;
otherwise it can be set to High (1) or Silent (3) for quiet areas.
Wrong Code Entry Limit:
After five (5) unsuccessful attempts at entering a valid PIN code, the unit
will shut down and not allow operation for sixty (60) seconds.
Model YRD226 Feature Programming Through Menu Mode Using Master PIN code*
-
Touch screen with back of hand or palm to activate
-
Enter 4-8 digit master PIN code* followed by key.
Lock Response: “Menu mode, enter number, press key to continue.” -
Enter digit corresponding to the function to be performed followed by the key.
Follow the voice commands.
Model YRD620 Feature Programming Through Menu Mode Using Master PIN code*
- Touch screen with back of hand or palm to activate .
- Enter 4-8 digit master PIN code* followed by key .
- Lock Response: “Menu mode, enter number, press key to continue.”
- Enter digit corresponding to the function to be performed followed by the key.
Follow the voice commands.
*The Master PIN code must be registered prior to any other programming of the lock.
Programming Troubleshooting
Symptom | Suggested Action |
---|---|
Lock does not respond – door is open and accessible. | Touchscreen becomes |
active when pressed w/whole hand. Use a larger area of the hand or fingers and verify contact with at least 3 areas.
If touchscreen numbers are visible, check to see if they respond when pressed.
Check batteries are installed and oriented correctly (polarity) in the battery case.
Check batteries are in good condition; replace batteries* if discharged.
Check to see if touchscreen harness is fully connected and not pinched.
Lock does not respond – door is locked and inaccessible.| Batteries may be
completely discharged. Use mechanical key to gain entry and replace
batteries.
Unit is on for a while then shows no reaction. Lights dim.| Batteries do not
have enough power. Replace batteries.
Unit chimes to indicate code acceptance, but the door will not open.| Check
the door gaps for any foreign objects between door and frame.
Check that the wire harness is firmly connected to the PCB.
Unit operates to allow access, but will not automatically re-lock.| Check to see if Auto Re-lock Mode is enabled.
Disable Auto Re-lock Mode to lock the door (automatically). If low battery indicator is lit (see below), change batteries*.
PIN codes will not register.| PIN codes must consist of 4 to 8 digits to
register. The same PIN code cannot be used for multiple users.
Registration/management of PIN codes is set by the authority of the Master
Code, which is set first. Contact the Master user. User codes must be entered
within 5 seconds (while touchscreen is active) or process will have to be
restarted. Check or gear cannot be used as part of the PIN code.
Upon entering a PIN code and pressing key, the unit displays “invalid code”
error or lock times out with- out responding.| Lockout Mode is enabled. Only
the Master can enable/disable Lockout Mode. Contact the Master user.
Upon entering a PIN code and pressing the key, the red padlock icon appears
and there are different tones.| Check to see if the lock is set to Lockout
Mode. Setting/managing Lockout Mode is done through Master Code only. Contact
the Master user.
The unit operates, but it makes no sound.| Check to see if Silent Mode is
enabled (see Feature #4).
The unit responds “Low Battery”| This is the alert to replace the batteries.
Replace all four (4) batteries* with new AA Alkaline batteries.
Upon entering a PIN code and pressing the key , the unit responds “Wrong
number of digits”.| **** The digits entered were incorrect or incomplete. Re-
enter the correct code followed by the check key.
- When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
** Network Module locks only
Hardware Troubleshooting
Cycle lock in both the locked and unlocked positions. If problems are found:
Door is binding
a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Bolt will not deadlock
a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the strike alignment.
Bolt does not extend or retract smoothly
a. Bolt and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to bolt.
c. Verify proper door preparation and re-bore holes that are too small or misaligned.
d. Verify keypad wire harness is routed under the bolt (see Fig. A).
e. Verify bolt is installed with correct side up (Fig. A).
Figure A
Keypad numerics are scrolling
Remove interior escutcheon and check to ensure that the wire harness lies flat against the back recessed area and is properly routed along the side of the escutcheon and tucked under the plastic cable guide.
Changing Lock: Replacing Cylinder
-
To Remove cylinder:
-
A. Remove outside escutcheon from door.
-
B. Remove rubber gasket.
-
C. Insert small flathead screwdriver under spring. Gently lift spring.
Note : Notch on top of cylinder engages spring. -
D. Remove cylinder by pulling outward towards outside of door. Before installing cylinder, be sure tailpiece is correct length (see below).
-
-
To install new cylinder:
- A. Reverse previous steps for removing cylinder.
FCC: Class B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning : Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user’s authority to operate the equipment.
Industry Canada:
This Class A digital apparatus meets all requirements of the Canadian
Interference Causing Equipment Regulations.
Product Support Tel 1-855-213-5841 www.yalehome.com Yale®, Yale Real Living® and Assure Lock® are registered trademarks of ASSA ABLOY Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. © Copyright 2019. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited.
Installing the Z-Wave® Plus Module
IMPORTANT : the batteries must be removed prior to removing and/or inserting the network module:
- Remove battery cover and batteries.
- Remove and/or insert Network Module.
- Reinstall batteries and battery cover.
Enrolling/Unenrolling the Network Module:
This device is a security enabled Z-Wave Plus product that is able to use
encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave
Plus products. This device must be used in conjunction with a Security Enabled
Z-Wave Controller in order to fully utilize all implemented functions. This
product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of
the network.
To Enroll/Add the Module
(Inclusion Mode):
- Enter the 4-8 digit Master PIN code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
To Unenroll/Remove the Module
(Exclusion Mode):
- Enter the 4-8 digit Master PIN code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
Factory Reset
If No Controller:
- See the Lock Installation Manual
- Please use this procedure only when the network primary controller is missing or otherwise inoperable.
For System Integrators:
Specific Z-Wave Plus association and parameter information for your lock is
available at YaleHome.com/ZwavePlus.
Warning : Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user’s authority to operate the equipment.
FCC:
Contain FCC ID: U4A-YRHCPZW FM0
Model : YRMZW2-US
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful Interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS.
- THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
- THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Industry Canada:
Contain IC: 6982A-YRHCPZW FM0
Model : YRMZW2-US
Section 7.1.2 of RSS-GEN
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Section 7.1.3 of RSS-GEN
This Device complies with Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions: 1) this device may not
cause interference, and 2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This radio transmitter 6982A-YRHCPZW FM0 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
CAN ICES-3B/NMB-3B
Product Support Tel 1-855-213-5841 www.yalehome.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
YALE, with its unique global reach and range of products, is the world’s favorite lock the preferred solution for securing your home, family and personal belongings. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
Installing the ZigBee® Module
IMPORTANT : the batteries must be removed prior to removing and/or inserting the network module:
- Remove battery cover.
- Remove batteries.
- Remove and/or insert network module.
- Reinstall batteries.
- Replace cover.
Enrolling/Unenrolling the Network Module:
This device is a security enabled ZigBee product that is able to use encrypted
ZigBee messages to communicate to other security enabled ZigBee products. This
device must be used in conjunction with a Security Enabled ZigBee Controller
in order to fully utilize all implemented functions. This product can be
operated in any ZigBee network with other ZigBee certified devices from other
manufacturers. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
To Enroll the Module
(Inclusion Mode):
- Enter the 4-8 digit Master PIN code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
To Unenroll the Module
(Exclusion Mode):
- Enter the 4-8 digit Master PIN code followed by the key.
- Press the key followed by the key.
- Press the key followed by the key.
FCC :
FCC ID : U4A-YRHCPZB FM0
Model: YRMZB2
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/CTV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by manufacturer could void the user’s authority to operate the equipment.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Industry Canada:
IC: 6982A-YRHCPZB FM0
Model : YRMZB2
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Important Note:
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. CAN ICES-3B/NMB-3B
Product Support Tel 1-855-213-5841 www.yalehome.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. YALE, with its unique global reach and range of products, is the world’s favorite lock the preferred solution for securing your home, family and personal belongings. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
FAQ’s
How many user codes can I create with the lock?
The maximum number of user codes depends on the network module being used. With Z-Wave Plus or ZigBee network module, you can create up to 250 user codes. Without a network module or with iM1 network module, you can create up to 25 user codes. With Bluetooth, you can create up to 12 user codes.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>