Electrolux ECHAG2-1000 3BE EEC Electric Convector Heater User Manual
- June 14, 2024
- Electrolux
Table of Contents
- Electrolux ECHAG2-1000 3BE EEC Electric Convector Heater
- Introduction
- Safety regulations
- General view of the device
- Operating modes and functions
- Open window” function
- Device control
- Installation of the device
- Troubleshooting
- Specifications
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Electrolux ECHAG2-1000 3BE EEC Electric Convector Heater
WE THINK ABOUT YOU
Thank you for purchasing an Electrolux appliance. You have chosen a product,
backed by decades of professional experience and innovations. Unique and
stylish, it was created with care for you. Therefore, whenever you use it, you
can be sure that the results will always be excellent. Welcome to Electrolux!
On our website, you can:
- Find product recommendations, user manuals, and maintenance information: www.home-comfort.com/support/
- Buy a product in your city: www.home-comfort.com/search/find-a-store/
- While selling this device, the dealer must fill “Product details” section located on the inside of the back cover of this manual.
Designation
Caution/Important safety information
INFO: Common information and recommendations
Warranty service is performed according to the terms specified in the
“Warranty” section.
Note:
- In the text of this manual, the electric convector may have such technical names as appliance, device, vehicle etc.
- This product is only suitable for well-insulated spaces or occasional use.
Introduction
Please read and strictly follow the requirements contained in this manual.
Please keep the manual and documents confirming the date of purchase of the
device in a safe place for easy retrieval and use.
The device is intended for air-heating in household premises.
Safety regulations
Caution
Non-following the manual can cause serious injury or serious equipment damage.
When using the device, observe the general safety rules when using electrical
devices. Failure to follow safety instructions and instructions can result in
electric shock, fire, and/or serious injury. Before using the device,
carefully read the following safety rules:
- When the heater is turned on for the first time, a characteristic smoke smell may occur due to the burning of oil in the heating elements. It is recommended to turn on the heater for 10-20 minutes in a well-ventilated area before installation.
- Any electrical appliance should be supervised, especially if there are children nearby. Make sure that children do not touch the device with their hands.
- Do not use the convector with damaged and/or damaged or frayed power cables.
- The mains cable must be positioned so that it is not stepped on, and that it is not abraded, torn, kinked or otherwise damaged.
- Do not allow foreign objects or liquids to enter the inside of the device.
- Always place the appliance in such a way in such a way as to prevent the possibility of ignition of flammable materials (for example, curtains). Make sure nothing is blocking the inlet and outlet ducts.
- To avoid fire, do not put clothing or other items on the device.
- Make sure that the bodies of the device and its heating element have cooled down before the device is dismantled and packed for long-term storage.
- Do not use the device in open spaces outdoors.
- Make sure that the mains voltage corresponds to that indicated on the label of the device.
- Do not try to repair the device yourself. Please contact your dealer.
- Unplug the device from the mains when not in use and before cleaning.
Purpose of the device
The device is designed for heating air in the household premises.
General view of the device
- Control unit
- Ventilation vents
- Ventilation inlets
- Chassis for floor installation (supplied separately)o
Control unit device
-
Control panel.
-
Control box retainer.
-
LED display.
-
Button to increase the value of target temperature.
-
Button for switching on/off the device + switching between Comfort, Eco, Anti-frost modes.
-
Button for turning on/off the open window function.
-
Button for reducing the target temperature.O
Indicators designation on LED display
- Indication of the current power of the heating element:
- full – two bars are lit;
- half – one bar is on.
- display of the target temperature and Display target temperature and errors.
- Wi-Fi connection status.
- Indication of the Open Window function.
- Indication of the convector work:
- lit red – the convector is on;
- not lit – the convector is off.
- Indication of the current heating mode:
- Comfort – orange;
- Eco – Eco-green;
- Anti-frost – blue.
- Indication of the status of the micathermic heating element operation.
Turning on the device
- Press the on/off button to put the unit into
- run mode. Press the button to turn on the device. The factory set temperature is +24 ºС.
Heating power setting
To turn on the half-power heating element, press the buttons simultaneously for 2 seconds. One bar will light up – half the power of heating. To turn on full power, press the buttons simultaneously for 2 seconds. Two bars will light up – full heating power.
Operating modes and functions
There are 3 temperature operating modes available for adjustment:
Comfort – range from 10 ºC to 35 ºC. Eco-deviation ranges from Comfort from 3
ºC to 7 ºC. Anti-Frost – a range from 3 ºC to 7 ºC.
Control the target heating temperature
- To increase the target temperature value, use the button
- To decrease the target temperature value use the button
The switching step is 1 degree.
Open window” function
When this function is active, when the temperature drops within 10 minutes
(and then up to 30 minutes) by 5 or more degrees – the Anti-Frost mode is
switched on the heater. If in the time interval 10 – 30 minutes the
temperature continues to drop, the device turns off. Further, the heater waits
for the stabilization of the decrease in the room temperature, if it rises by
2 degrees, then the last set mode is turned on.
To activate/deactivate the control panel lock of the control panel, press the
.
Parental control” function
To activate/deactivate the control panel lock of the control panel, press the buttons and for 12 seconds at the same time.
Auto Restart Resume” function
In the event of a short-term power outage, and its further inclusion, the
convector automatically switches to the operating mode, while maintaining the
last operating mode of the device and the set temperature (if a timer was set,
the set shutdown time is saved). If the device was in standby mode when the
power was turned off, it will remain in the same mode when the power supply is
restored.
Overheating protection” function
The device is equipped with an automatic switch that is activated when the
upper-temperature limit is reached. The heater switches off automatically in
case of overheating. After eliminating the source of overheating, the heater
will turn on automatically.
Switching off the appliance
To turn off the device, press the button in any operating mode.
Device control
Preparation for work
- Carefully remove the heater from the cardboard box.
- Remove the colored stickers from the front panel before use.
- At the first start-up, some odor may appear, which will disappear after the convector starts to work.
- Fix the device in a stable position according to the assembly and installation instructions.
- After installing the convector, plug it into a power outlet.
- It is not recommended to use the same electrical outlet for simultaneous plugging in the heater and other high-power electrical appliances.
Wi-Fi Pairing Mode
To put the Wi-Fi module in Pairing mode, you must press the buttons and
simultaneously for 2 seconds. The Wi-Fi icon will start blinking once per
second. If the connection is successful, the Wi-Fi icon will start to light up
steadily.
Wi-Fi statuses:
- The icon is not lit – the device is not connected;
- Icon blinking – pairing mode;
- The icon lights up – the device is connected
Micathermic heating element
- To turn on the micathermic heating element, simultaneously press the and for 2 seconds.
- The icon of the microthermal heating element will light up.
- This means that in addition to the main heating element, the micathermic one will also operate.
Installation of the device
Recommended installation
- The device must be fixed under the regulations.
- The switch and other mechanisms must stay away from splashing water. It is strictly forbidden to cover or plug the air inlets or outlets (grilles), due to the risk of accident or damage to the device. Do not place behind curtains, doors, walls, or air vents.
- Observe the minimum installation distances on floors, surfaces, furniture, etc.
Wall mounted installation option (bracket and mounting template included)
Use the brackets to mount the heater on the wall according to the pictures
below. The distance from the device to the floor and surrounding objects must
be at least 10 cm (Figure 5):
To install the bracket on a wall, follow these steps:
- Attach the mounting template to the wall in the place where you plan to place the vector.
- Mark and drill holes.
- Place the bracket on the wall and secure it with the fasteners.
Fix the device to the bracket as follows (Figure 6):
- Place the lower part of the convector onto the bracket using the special holes located in the lower part of the convector.
- Slide the upper part of the convector onto the bracket, fixing it with the latches on the bracket.
Floor installation
Using the chassis (supplied separately), having previously studied the
mounting scheme (Figure 7), install the device on the floor:
- Carefully turn the convector upside down.
- Take one of the chassis and attach to the landing area on the right or left side of the convector so that it fits snugly against the convector body
- Secure the chassis using the supplied mount.
- Repeat the same procedure for attaching the second chassis.
Care
- The convector does not require any special maintenance. Before servicing (leaving) the convector must be disconnected from the power supply.
- The body of the device should be periodically wiped with a soft, lint-free cloth or damp sponge. Never use abrasive, foaming detergents or solvents. It is quite easy to clean the space behind a wall-mounted heater.
- Press down the two latches on the back of the heater and pull the heater forward. After it is removed, you can wash the wall on which it was installed.
- After finishing cleaning, put the heater back in its normal operating position.
Recommended indoor temperature and humidity:
- a) for the convector operation: from -25°С to + 30°С, humidity from 40% to 90%;
- b) for the storage of the convector : from -20°C to + 80°С, humidity from 40% to 90%.
Troubleshooting
Malfunction symptom|
Cause of malfunction
|
Troubleshooting steps
---|---|---
No heating
|
1) There is no power supply.
2) The convector is in standby mode.
3) The actual room temperature is higher than the thermostat setting.
|
1) Establish a reliable connection.
2) Set the convector to operating mode.
3) Adjust the temperature mode of the convector.
Smell of burnt dust when first turned on
|
Not a malfunction
|
The smell disappears after a few minutes of convector operation
If after trying all the troubleshooting steps, the problem is not resolved, contact an authorized service cen-ter in your area or your sales representative.
Specifications
Model| ECH/AG2-1000 3BE EEC| ECH/AG2-1300 3BE EEC|
ECH/AG2-1500 3BE EEC| ECH/AG2-2000 3BE EEC| ECH/AG2-2500
3BE EEC
---|---|---|---|---|---
Power, W| 900-1000| 1150-1300| 1350-1500| 1800-2000| 2250-2500
Rated power consumption, W| 900-1000| 1150-1300| 1350-1500| 1800-2000|
2250-2500
Rated current, A| 4.1-4.17| 5.23-5.42| 6.14-6.25| 8.18-8.33| 10.23-10.42
Rated voltage, V~Hz| 220/240
~50/60
| 220/240
~50/60
| 220/240
~50/60
| 220/240
~50/60
| 220/240
~50/60
Ingress protection class| IP24| IP24| IP24| IP24| IP24
Electrical protection class| I| I| I| I| I
Heating area, m2| 9-10| 11-13| 13-15| 18-20| 22-25
Appliance size (W×H×D), mm| 480×139×413| 560×139×413| 640×139×413|
800×139×413| 1000×139×413
Packing size (W×H×D), mm| 575×167×445| 655×167×445| 735×167×445| 895×167×445|
1095×167×445
Net weight, kg| 3.8| 4.0| 4.3| 5.4| 7.5
Gross weight, kg| 4.7| 4.9| 5.4| 6.5| 9.0
Indicated is a guideline value and may differ depending on actual conditions of use The convector is supplied with a sticker on the front panel. Remove it before using the device.
Error Display
- E1 – Temperature sensor failure;
- E2 – Short circuit on the temperature sensor channel;
- E3 – Temperature sensor overheated. Current temperature exceeded +48˚C;
- E4 – The ambient temperature has fallen below the permissible operating temperature of the unit (below -26 ˚C).
Completing units
- Electric heater
- Wall mounting bracket
- Mounting template
- A set of fasteners
- Operation manual
- Chassis set with wheels
Storing the appliance
Make sure the heater is cool before storing it. It is recommended to clean the
heater and store (preferably in the original packaging) in a cool dry place in
case you plan not to use device for a long time.
Recycling
The time-expired appliance can’t be disposed of with household waste
(2012/19/EU).
Warranty
Warranty service is performed according to the terms specified in the “Warranty” section.
Warranty
- The warranty period for the item is two years from the purchase date. If any defects occur due to defects in materials and/or workmanship during this two-year warranty period, the item should be repaired or replaced.
- Free maintenance or replacement is possible only in case convincing evidence is provided, for example, a stub, which confirms that the day when the service is requested, is within the warranty period.
- The warranty does not cover products and/or parts of the product that are subject to deterioration, may be considered expendable supplies, or are made of glass.
- The warranty is void if the defect is caused by damage ensuing from misuse, poor maintenance (for example, a failure occurred due to ingress of foreign objects or liquids) or if changes or repairs were performed by persons not authorized by the Manufacturer.
- For the correct use of the product, the user must strictly follow all included in the manual instructions and also must avoid any action or manipulation described as unwanted or indicated in this manual.
- These warranty restrictions do not affect your statutory rights.
Support:
The support during and after the warranty period is available in all countries
where the product is officially distributed. Please contact your dealer for
help.
Date of manufacture
The date of manufacture is indicated on a sticker on the body of the appliance
and also encrypted in Code-128. The date of manufacture is determined as
follows:
Do not remove and keep safe the serial number on the device’s body. If the serial number sticker is lost or damaged, it will not be possible to restore the production date if necessary.
Manufacturer: CladSwiss AG, Bahnhofstrasse 27, 6300 Zug, Switzerland. E-mail: info@cladswiss.com
Made in PRC
- Electrolux is a registered trademark used under license from AB Electrolux (publ.).
- The manufacturer reserves the right to modify the design and characteristics of the device.
- This manual may contain technical and typing errors. Changes to technical characteristics and assortment are subject to change without notice.
- Mistakes and typing errors may be permitted in texts and numeric notations.
- Product design and technical data may vary from the one pictured on the packaging. Please refer to a sales consultant for more detailed information.
Information required for thе electric local space heaters
Model identifier(s): ECH/AG2-1000 3BE EEC
item| Symbol| Value| Unit| item| Unit
Heat output| Туре of heat input, for electric
storage local space heaters only (select one)
Nominal heat output| Phnom| 0,9151| kW| manual heat charge control, with
integrated thermostat| NO
Minimum heat output (indicative)|
Pmin
|
0,4571
|
kW
| Manual heat charge control with room and/or outdoor temperature feedback|
NO
Maximum continuous heat output|
Pmax,c
|
0,9151
|
kW
| electronic heat charge control with room and/or outdoor
temperature feedback
|
NO
Auxiliary electricity consumption| fan-assisted heat output| NO
At nominal heat output| max| 0| kW| Туре of heat output/room temperature
control (select one)
At minimum heat output| Elgin| 0| kW| single-stage heat output and nо room
temperature control| NO
ln standby mode| else| 0.00041| kW| two оr more manual stages, nо room
temperature control| NO
| | | | with mechanic thermostat room temperature control| NO
| | | | with electronic room temperature control| NO
| | | | electronic room temperature control plus a day timer| NO
| | | | electronic room temperature control plus week timer| YES
| | | | Other control options (multiple selections
possible)
| | | | room temperature control, with presence detection| NO
| | | | room temperature control, with open window detection| YES
| | | | with a distance control option| YES
| | | | with adaptive start control| NO
| | | | with working time limitation| NO
| | | | with blасk bulb sensor| NO
Model identifier(s): ECH/AG2-1500 3BE EEC
item| Symbol| Value| Unit| item| Unit
Heat output| Туре of heat input, for electric
storage local space heaters only (select one)
Nominal heat output| Phnom| 1,3831| kW| manual heat charge control, with
integrated thermostat| NO
Minimum heat output (indicative)|
Pmin
|
0,6837
|
kW
| Manual heat charge control with room and/or outdoor temperature feedback|
NO
Maximum continuous heat output|
Pmax,c
|
1,3831
|
kW
| electronic heat charge control with room and/or outdoor
temperature feedback
|
NO
Auxiliary electricity consumption| fan-assisted heat output| NO
At nominal heat output| max| 0| kW| Туре of heat output/room temperature
control (select one)
At minimum heat output| Elgin| 0| kW| single-stage heat output and nо room
temperature control| NO
ln standby mode| else| 0.00039| kW| two оr more manual stages, nо room
temperature control| NO
| | | | with mechanic thermostat room temperature control| NO
| | | | with electronic room temperature control| NO
| | | | electronic room temperature control plus day timer| NO
| | | | electronic room temperature control plus week timer| YES
| | | | Other control options (multiple selections
possible)
| | | | room temperature control, with presence detection| NO
| | | | room temperature control, with open window detection| YES
| | | | with a distance control option| YES
| | | | with adaptive start control| NO
| | | | with working time limitation| NO
| | | | with blасk bulb sensor| NO
Model identifier(s): ECH/AG2-2000 3BE EEC
item| Symbol| Value| Unit| item| Unit
Heat output| Туре of heat input, for electric
storage local space heaters only (select one)
Nominal heat output| Phnom| 1,8546| kW| manual heat charge control, with
integrated thermostat| NO
Minimum heat output (indicative)|
Pmin
|
0,9313
|
kW
| Manual heat charge control with room and/or outdoor temperature feedback|
NO
Maximum continuous heat output|
Pmax,c
|
1,8546
|
kW
| electronic heat charge control with room and/or outdoor
temperature feedback
|
NO
Auxiliary electricity consumption| fan-assisted heat output| NO
At nominal heat output| max| 0| kW| Туре of heat output/room temperature
control (select one)
At minimum heat output| Elgin| 0| kW| single-stage heat output and nо room
temperature control| NO
ln standby mode| else| 0.00039| kW| two оr more manual stages, nо room
temperature control| NO
| | | | with mechanic thermostat room temperature control| NO
| | | | with electronic room temperature control| NO
| | | | electronic room temperature control plus a day timer| NO
| | | | electronic room temperature control plus week timer| YES
| | | | Other control options (multiple selections
possible)
| | | | room temperature control, with presence detection| NO
| | | | room temperature control, with open window detection| YES
| | | | with a distance control option| YES
| | | | with adaptive start control| NO
| | | | with working time limitation| NO
| | | | with blасk bulb sensor| NO
Model identifier(s): ECH/AG2-2500 3BE EEC
item| Symbol| Value| Unit| item| Unit
Heat output| Туре of heat input, for electric
storage local space heaters only (select one)
Nominal heat output| Phnom| 2,3219| kW| manual heat charge control, with
integrated thermostat| NO
Minimum heat output (indicative)|
Pmin
|
1,1731
|
kW
| manual heat charge control with room and/or outdoor temperature feedback|
NO
Maximum continuous heat output|
Pmax,c
|
2,3219
|
kW
| electronic heat charge control with room and/or outdoor
temperature feedback
|
NO
Auxiliary electricity consumption| fan-assisted heat output| NO
At nominal heat output| max| 0| kW| Туре of heat output/room temperature
control (select one)
At minimum heat output| Elgin| 0| kW| single-stage heat output and nо room
temperature control| NO
ln standby mode| else| 0.00041| kW| two оr more manual stages, nо room
temperature control| NO
| | | | with mechanic thermostat room temperature control| NO
| | | | with electronic room temperature control| NO
| | | | electronic room temperature control plus a day timer| NO
| | | | electronic room temperature control plus week timer| YES
| | | | Other control options (multiple selections
possible)
| | | | room temperature control, with presence detection| NO
| | | | room temperature control, with open window detection| YES
| | | | with a distance control option| YES
| | | | with adaptive start control| NO
| | | | with working time limitation| NO
| | | | with blасk bulb sensor| NO
Product Details (populated upon sale)
- Model
- Serial number
- Date of sale
- Seller Seal
Electrolux is a registered trademark used under license from AB Electrolux
(publ.).
This manual may contain technical and typing errors. Changes to technical
characteristics and assortment are subject to change without notice.
www.home-comfort.com
You can get additional information about this and other products directly from
the Seller or through our information lines: Contact us at «CladSwiss»
Switzerland, 6300 Zug, Bahnhofstrasse.
About the equipment purchase and cooperation:
- Tel: +41 41 532 50 00
- E-mail : info@cladswiss.com
For technical and service issues:
- Tel. +41 41 532 50 01
- E-mail: service@cladswiss.com
- Internet address: www.home-comfort.com
Read User Manual Online (PDF format)