SAFETY REGULATIONS FOR AIRLESS SPRAYING

All local safety regulations in force must be observed.

The following sources are just a sample of those containing safety requirements for Airless spraying.

  • a) The European Standard „Spray equipment for coating materials – safety regulations „ (EN 1953: 1998).

The safety regulations of the manufacturer of the Airless unit are to be observed in order to ensure safe handling of the Airless high-pressure spraying unit.

Observe the following additional safety instructions during operation with these specified heating-hoses:

FLASH POINT

DANGER

Only spray coating materials with a flash point of at least 5 kelvin higher than the set temperature (minimum flash point is 21°C). The flash point is the lowest temperature at which vapors develop from the coating material. These vapors are sufficient to form an inflammable mixture over the air above the coating material.

EXPLOSION PROTECTION

DANGER

Do not use the unit in work places which are covered by the explosion protection regulations.

The unit is not designed to be explosion protected.

DANGER OF EXPLOSION AND FIRE FROM SOURCES OF IGNITION DURING SPRAYING WORK

DANGER

There must be no sources of ignition such as, for example, open fires, lit cigarettes, cigars or tobacco pipes, sparks, glowing wires, hot surfaces, etc. in the vicinity

ELECTRIC CHARGE (SPARK AND FLAME FORMATION)

DANGER

Due to the flow speed of the coating material in the hose, there is the possibility of electrostatic charging at the equipment. These can involve spark or flame formation at discharge. Therefore it is necessary that the Airless-unit is earthed according to directions at all time.

Electrostatic charging of spray guns and the high-pressure hose is discharged through the high-pressure hose. For this reason the electric resistance between the connections of the high-pressure hose must be equal or lower than 1 MΩ. The resistance of the TempSpray – H126 must be equal or lower than 2 Ohm.

EARTHING OF THE OBJECT

The object to be coated must be earthed. (Building walls are usually earthed naturally)

PROTECTIVE EARTHING OF THE HEATING HOSE

In case of defect (of the heating conductor), protection against an electric shock is secured by the protective earthing of the heating hose. This earthing is implemented by the electric supply to a shock proof socket

DANGER

Be sure that the grounding of the shock proof socket, to which the heating- hose will be connected, is installed as prescribed and functioning.

USE OF UNITS ON BUILDING SITES AND WORKSHOPS

The unit may only be connected to the mains network via a special feeding point with a residual-current device with INF ≤ 30 mA.

Wagner‘s accessories program also includes a mobile operator protection device for the electronic supply, which can also be used with other electronical equipment.

HIGH PRESSURE HOSE

DANGER

Attention, danger of injury by injection! Wear and tear and kinks as well as usage that is not appropriate to the purpose of the device can cause leakages to form in the high-pressure hose. Liquid can be injected into the skin through a leakage.

  • High-pressure hoses must be checked thoroughly before they are used.
  • Replace any damaged high-pressure hose immediately.
  • Never repair defective high-pressure hoses yourself!
  • Avoid sharp bends and folds: the smallest bending radius is about 20 cm.
  • Do not drive over the high-pressure hose. Protect against sharp objects and edges.
  • Never pull on the high-pressure hose to move the device.
  • Do not twist the high-pressure hose.
  • Do not put the high-pressure hose into solvents. Use only a wet cloth to wipe down the outside of the hose.
  • Lay the high-pressure hose in such a way as to ensure that it cannot be tripped over

Only use WAGNER original-high-pressure hoses in order to ensure functionality, safety and durability.

PERSONAL PROTECTION WHILE HOT SPRAYING

DANGER

During all spraying with a temperature-setting of more than 43°C (display on the control panel starts blinking) take adequate safety measures against combustion.

  • Wear protective gloves.

Attention: The high-pressure hose and the hose whip are heated, too!

Use of a plastic coated spray gun is recommended.

CLEANING THE UNIT

DANGER

Danger of short-circuits caused by water ingression!

Never spray down the unit with high-pressure or high-pressure steam cleaners

CLEANING THE UNIT WITH SOLVENTS

DANGER

When cleaning the unit with solvents, the heating of the heating hose has to be switched off, because an explosive gas/air-mixture can emerge in the hose. The solvent should neverbe sprayed or pumped back into a container with a small opening (bunghole). An explosive gas/air mixture can arise. The container must be earthed.

WORK OR REPAIRS AT THE ELECTRICAL EQUIPMENT

These may only be carried out by a skilled electrician. No liability is assumed for incorrect installation

WORK AT ELECTRICAL COMPONENTS

Unplug the power plug from the outlet before carrying out any repair work.

OVERVIEW OF APPLICATION

RANGE OF APPLICATION

The heating-hoses TempSpray-H326, TempSpray-H226 and TempSpray-H126 are designed for all established Airless paints praying devices, whose operating pressure is below the rated pressure of the heating-hoses

With some electronically controlled Airlessdevices, the operation of a TempSpray-H126 can lead to malfunctions. To avoid this, mount a shock absorber (e.g. a 15m meter long textile reinforced high-pressure hose) between the device and the heating hose.

With the heating-hoses, mainly water-based colours can be heated from 20°C to 60°C, to improve the spraying on the Airless-nozzle.

Thereby it is possible to improve both spray result and material consumption. This depends on the used material and the calibration of the parameters. The heating-hoses can be used both in workshops and on construction sites.

Due to the cross-section and the operation length, the TempSpray-H326 is adapted well for high-viscosity materials outdoors.

Due to its shorter hose, TempSpray -H226 is recommended for smaller objects and indoor work.

Both hoses are qualified for the operation of an inside-fed paint roller.

In the lacquer sector TempSpray -H326, -H226 and -H126 can be used, but pay attention to the safety instructions, especially in reference to explosion protection.

The TempSpray-H126 is specifically conceived for lacquer work. Its minor hose- section raises the handling and reduces the needed volume of lacquer to fill the hose.

The TempSpray-H126 is not capable for high-viscosity materials and big nozzles.

TempSpray heated hoses must not be used in areas that come under the Explosion Protection Ordinance.

COATING MATERIAL

Diluting lacquers and paints or those containing solvents, two component coating materials, dispersion and latex paints.

No other materials should be used for spraying without WAGNER‘s approval. In particular, airless spray putty, high-viscosity coating substances such as, e.g. roof coatings and corrosion protection

No other materials should be used for spraying without WAGNER‘s approval.

Pay attention to the Airless quality of the coating materials to be processed.

DANGER

Regard the directions from the color manufacturer (technical data sheets of the colors):

Some colours will be destroyed, if they are heated over a certain level. Some colours attain a high viscosity, thus they can damage the heating wire in the hose.

The TempSpray-H326/H226 can be used for coating materials with a viscosity up to 25,000 mPas.

The heating-hose TempSpray-H126 can be used for coating materials with a viscosity up to 5,000 mPas.

COATING MATERIALS WITH SHARP-EDGED ADDITIONAL MATERIALS

These particles have a strong wear and tear effect on valves and tips, but also on the heating hose and spray gun. This impairs the durability of these wearing parts considerably

DESCRIPTION OF UNIT

GENERAL FUNCTION OF THE DEVICES

For a better understanding of the function see the technical configuration below:

All 3 heating-hoses are heated via an electric conductor, which is located directly in the colour-flow in the inside of the hose. An electric current flows trough the heating conductor, which is thereby heated up. Thereupon it changes its electrical resistance proportional to its temperature. The electronic system in the governor housing measures this resistance constantly and calculates the temperature of the heating conductor out of it, without any further sensor. The control electronics adapts the current flow so that the set temperature is kept constant.

The output of the heating-hoses is limited. If the volume flow rate is too high (nozzle too big) or the temperature of the materials before processing is too low, the results may vary. Of course the surrounding air temperature has an effect on the heating-ability of the heating-hoses, too.

Calculated values for the orientation can be found in the specification of each heating-hose.

EXPLANATORY DIAGRAM
EXPLANATORY DIAGRA
EXPLANATORY DIAGRA EXPLANATORY
DIAGRA

  1. HP hose
  2. Hose whip
  3. Connecting hose
  4. Power cord
  5. Hose drum
  6. Frame
  7. Lock wheel
  8. Governor housing
  9. Control panel with display
  10. Screw connexion (TempSpray-H126)
  11. Telescopic handle
  12. Hose guide with roller
  13. Cable holder
  14. Park fitting for fixing the hose during transport

TRANSPORT

TempSpray-H326 and TempSpray-H226:

Roll up the high-pressure hose and fix to the hose guide park fitting. Coil connecting hose over the cable holder and connect it to the park fitting as well. Roll up the mains connection cable onto the cable holder.

Pull the locking pins (Item 1) on both sides of shaft. The locking pins can be arrested by a small turn (left or right). Pull the shaft out and deblock the locking pins. A light pull or push will help to lock the pins well.

DANGER

Carry the device – don’t throw it!

TempSpray-H126:

Roll up the high-pressure hose (roll diameter greater than 20 cm).

Then roll up the power cord as well. The advice can be transported with the Airless-unit on which it is mounted (See details for transport of the Airless- unit).

TECHNICAL DATA TEMPSPRAY-H326

  • Voltage : 230 Volt ~, 50 – 60 Hz

  • Fuses : 16 A

  • Power cord : 6 m long, 3×1.5 mm²

  • Max. current consumption : 5.2 A

  • Degree of protection : IP 54

  • Max. heating output : 1.1 kW

  • Max. operating pressure : 25 MPa (250 bar)
    Hose : DN10-30m-textile reinforced

  • Inner diameter : 10 mm

  • Length : 30 m

  • Fitting : 3/8” NPSM

  • Hose whip : DN5-1m-steel reinforded

  • Inner diameter : 5 mm

  • Length : 1 m

  • Fitting : 1/4” NPSM

  • Connecting hose : DN6-1.6m-textile reinforced

  • Inner diameter : 6 mm

  • Length : 1.6 m

  • Fitt ing : 1/4” NPSM

  • Max. viscosity of the

  • coating material : : 25,000 mPas

  • Adjustable temperature range: 20°C – 60°C

  • Dead weight : 16.8 kg]

  • Performance :

  • Max. nozzle size :
    (Continuous operation with water): 0.015”; more than 50°C -> 0.013”

  • Max. nozzle size:
    (Continuous operation with emulsion paint): 0.023”; more than 50°C -> 0.019”

based on surrounding and material temperature of 20°C. During intervallic operation (gun opened/closed) bigger nozzles can be used.

TECHNICAL DATA TEMPSPRAY-H226

  • Voltage : 230 Volt ~, 50 – 60 Hz

  • Fuses : 16 A

  • Power cord : 6 m long, 3×1.5 mm²

  • Max. current consumption : 5.9 A

  • Degree of protection :: IP 54

  • Max. heating output: 1.3 kW

  • Max. operating pressure : 25 MPa (250 bar)

  • Hose : DN10-15m-textile reinforced

  • Inner diameter : 10 mm

  • Length : 15 m

  • Fitting : 3/8” NPSM

  • Hose whip : DN5-1m-steel reinforced

  • Inner diameter : 5 mm

  • Length : 1 m

  • Fitting : 1/4” NPSM

  • Connecting hose : DN6-1.6m-texile reinforced

  • Inner diameter : 6 mm

  • Length : 1.6 m

  • Fitting : 1/4” NPSM

  • Max. viscosity of the

  • coating material: 25,000 mPas

  • Adjustable temperature range: 20°C – 60°C

  • Dead weight : 13.2 kg

  • Performance :

  • Max. nozzle size :
    (Continuous operation with water): 0.013”; more than 50°C -> 0.011”

  • Max. nozzle size :
    (Continuous operation with emulsion paint): 0.021”; more than 50°C -> 0.019”

based on surrounding and material temperature of 20°C. During intervallic operation (gun opened/closed) bigger nozzles can be used.

TECHNICAL DATA TEMPSPRAY-H126

  • Voltage : 230 Volt ~, 50 – 60 Hz
  • Fuses : 16 A
  • Unit connecting line : 4 m long, 3×1.5 mm²
  • Max. current consumption : 2.6 A
  • Degree of protection : IP 54
  • Max. heating output : 0.6 kW
  • Max. operating pressure : 25 MPa (250 bar)
  • Hose : DN6-10m-steel reinforced
  • Inner diameter : 6 mm
  • Length : 10 m
  • Fitting : 1/4” NPSM
  • screw connection to the
  • device 1/4” NPSM
  • Max. viscosity of the
  • coating material : 5,000 mPas
  • Adjustable temperature range: 20°C – 60°C
  • Dead weight : 3.2 kg

Performance :
Max. nozzle size :
(Continuous operation with water)
0.011”;
more than 50°C -> 0.009”

Max. nozzle size :
(Continuous operation with emulsion paint)
0.015”;
more than 50°C -> 0.013”

  • based on surrounding and material temperature of 20°C. During intervallic operation (gun opened/closed) bigger nozzles can be used.

STARTUP

TEMPSPRAY-H326 AND TEMPSPRAY-H226

  1. Place hose drum close to the Airless-unit.
  2. Release hose whip (1) from frame and roll up the highpressure hose. Also release the lock-advice (2) and lock it again after rolling the hose up.
  3. Release connecting hose and connect it to the hose adapter of the airless-unit.
  4. Mount spray gun (4) to the hose whip.
  5. Tighten all coupling nuts strongly, in order that no coating material can leak.
  6. Mount the nozzle holder with the chosen nozzle on the spray gun, position it and tighten it well (See manual of the spray gun/ nozzle holder).

DANGER

For safety reasons never use the heating hose without the steal-armored hose whip, if working with a spray gun.

DANGER

Counter with a wrench, if you unscrew the high-pressure hose from the hose connector

CONNECTION TO THE MAINS NETWORK

DANGER

Connection must always be carried out via an appropriately grounded safety outlet with residual-current-operated circuit-breaker.

Before connecting the unit to the mains supply, ensure that the line voltage matches that specified on the unit’s rating plate.

CLEANING PRESERVING AGENT WHEN STARTING-UP OF OPERATION INITIALLY

Rinse the heating hose with a suitable cleaning agent (recommendation: water) at a low pressure setting.

Therefore use a spray gun without nozzle and spray into an open box.

TEMPSPRAY-H126

  1. Mount the governor housing (1) to the hose connector of the airless-unit, thereby arrange the housing in a way that you can reach the control panel easily and no important accesses are barred.
  2. Roll up the high-pressure hose.
  3. Mount spray gun (2) to the high-pressure hose.
  4. Tighten all coupling nuts well, in order that no coating material can leak.
  5. Mount the nozzle holder with the chosen nozzle on the spray gun, position it and tighten it well (See manual of the spray gun/ nozzle holder).

CONNECTION TO THE MAINS NETWORK

** Attention**

Connection must always be carried out via an appropriately grounded safety outlet with residual-current-operated circuit-breaker.

Before connecting the unit to the mains supply, ensure that the line voltage matches that specified on the unit’s rating plate.

CLEANING PRESERVING AGENT WHEN STARTING-UP OF OPERATION INITIALLY

Rinse the heating hose with a suitable cleaning agent (recommendation: water) at a low pressure setting.

Therefore use a spray gun without nozzle and spray into an open box.
CONNECTION
SWITCH-ON

Connect the heat controller to the mains supply. OFF appears in the display window (A) to indicate operational readiness.

Press the START button (B), to switch the heat controller on.

The display window changes from OFF to the preset temperature of 40°C and the heating process begins.

While the material in the heated hose is being heated, a dot illuminates in front of the temperature display. As soon as this goes out, it will take another approx. 2 minutes until the material reaches the set temperature.

If the dot illuminates again during the work cycle, the material in the hose is heated further, in order to keep the set temperature constant.

If the illuminated dot no longer disappears and the spray result deteriorates, a smaller nozzle should be used for this material.

TEMPERATURE ADJUSTMENT

The Temperature can be raised or reduced in 1° steps by using the foil-buttons and (C) (“°C” flashes during adjustment). To set the temperature you adjusted, you have to push the set-button START (B) within 3 seconds, otherwise the heating control resets to the temperature that was used before.

If you press on of the buttons and (C) constantly, the adjustment-speed raises. After confirming with START, “°C” illuminates constantly.

The adjustment range is from 20°C to 60°C. A change in every direction is always possible.

The heating can take a couple of minutes until the adjusted temperature is reached. This depends on the start temperature of the material and on the surrounding temperature. It is assumed that the heating time takes from 3 to 8 minutes.

At temperature adjustments over 43°C, the display value starts blinking. This is a hint for possible danger of getting burnt.

Temp Spray – H126
Temp Spray

Temp Spray – H326 / -H226
Temp Spray

HANDLING THE HIGH-PRESSURE HOSE

DANGER

Danger of injury through leaking high-pressure hose. Replace any damaged high pressure hose immediately. Never repair defective high-pressure hoses yourself!

DANGER

The high-pressure hose can’t be removed from the hose reel or the controller housing. Never try to loosen the connection.

The high-pressure hose is to be handled with care. Avoid sharp bends and folds: the smallest bending radius is about 20 cm.

Do not drive over the high-pressure hose. Protect against sharp objects and edges.

Never pull on the high-pressure hose to move the device.

Always unroll the high-pressure hose completely.

When using the high-pressure hose while working on scaffolding, it is best to always guide the hose along the outside of the scaffolding.

The risk of damage rises with the age of the high-pressure hose. Wagner recommends replacing high-pressure hoses after 6 years.

Only use WAGNER original-high-pressure hoses with internal heating in order to ensure functionality, safety and durability.

INTERRUPTION OF WORK

Release the pressure in the hose and switch off the heating during longer breaks.

In using quick-drying or two-component coating materials, do not fail to rinse unit through with a suitable cleaning agent during the processing period.

Important: The application life of the material can change as a result of heating. Therefore, please consult the material manufacturer.

CLEANING THE DEVICE

A clean state is the best method of ensuring operation without problems. After you have finished spraying, clean the unit.

Under no circumstances may coating material rests dry and harden in the unit.

Clean the device with an adequate detergent, after finishing the paint work.

The solvent used for cleaning (with a flash point over 21 °C) has to be adequate to the coating material.

DANGER

While cleaning with solvents (except water) always switch off heating.

DANGER

Do not put the high-pressure hose into solvents. Use only a wet cloth to wipe down the outside of the hose.

DANGER

The container must be earthed in case of coating materials which contain solvents (except water).

DANGER

Caution! Do not pump or spray in container with small opening (bunghole)! See safety regulations.

When cleaning without a nozzle, reduce the pressure to approx. 20 bar.

Warm water improves the cleaning effect in the case of water-dilatable coating materials. Therefore the heating can stay switched on.

CLEANING   THE UNIT FROM THE OUTSIDE

DANGER

First unplug the power plug from the outlet. Danger of short-circuits caused by water ingression! Never spray down the unit with high-pressure or high- pressure steam cleaners.

Wipe unit externally with a piece of cloth, which has been immersed in a suitable cleaning agent.

SERVICING

GENERAL SERVICING

After the regulations of the Accident Prevention & Insurance Association an annual expert check is required- inclusive confirmation

You can servicing of the unit carried out by the Wagner Service. Favorable conditions can be agreed with a service agreement and/ or maintenance packages.

Minimum check before every startup:

  1. Check the high-pressure hose, power supply cable with plug for damage. Inspect the high-pressure hose visually for any notches or bulges, in particular at the transition in the fittings.

Check at periodical intervals:

  1. The coupling nuts have to be clearly rotatable. The conductivity has to be less than 1 Mega Ohm (Tempspray-H326, Tempspray-H226) alternatively less than 2 Ohm (TempSpray-H126) over the whole length.

  2. Check the status of the heating conductor To do this, press and hold down the “START” and buttons simultaneously, and also press the button. If “0A” appears in the display, the heating conductor is ok.
    If a different value is shown for “A” (e.g. 5A), please contact Wagner Service to arrange for an insulation test.

  3. The isolation of the heating wire has to be tested with an insulation tester with at least 1000V.

** Attention**

Have all the electric tests carried out by the Wagner Service.

REPAIRS AT THE UNIT

DANGER

Switch the unit off. Before all repair work: Unplug the power plug from the outlet.

Due to necessary custom tools repairs on the heating wire and the heating wire feed have to be done only by the Wagner Service.

A replacement of the heating-hose should, due to its internal heating wire, only be done from the Wagner-Service as well. The hose whips of the TempSpray-H326 and TempSpray-H226 can be replaced without any problems.

REMEDY IN CASE OF FAULTS

DISPLAYED ERROR CODE POSSIBLE CAUSE MEASURES FOR ELIMINATING THE MALFUNCTION
Err0 Residual current exceeded (approx. 33mA) and relay cuts out:•

Heating conductor insulation in hose dam- aged•                     Cable has come loose•                     Water has penetrated device| Please contact Wager Customer Service
Err1| Electronics defective – no communication be- tween the boards| Disconnect the device from the power supply. Wait approx. 30 seconds and switch it back on. If the error code is still displayed, contact Wag- ner Customer Service.
Err2| Control board does not receive any feedback| Disconnect the device from the power supply. Wait approx. 30 seconds and switch it back on. If the error code is still displayed, contact Wag- ner Customer Service.
Err3| Interface board does not receive any feedback/no information is received by the interface board **** Cables pinched in housing| Disconnect the device from the power supply. Wait approx. 30 seconds and switch it back on. If the error code is still displayed, contact Wag- ner Customer Service.Have a skilled electrician open the housing and check the cables.
Err4| Heating resistance too large:Current flow in heating conductor is inter- ruptedOvertemperature protection has actuated| Disconnect the device from the power supply. Wait approx. 30 seconds and switch it back on. If the error code is still displayed, contact Wag- ner Customer Service.
Err5| Heating resistance too small: Short-circuit in heating wire| Disconnect the device from the power supply. Wait approx. 30 seconds and switch it back on. If the error code is still displayed, contact Wag- ner Customer Service.
Temperature is displayed in °F instead of °C| Temperature display converted to Fahrenheit| Press „START“ and „         “ simultaneously to con- vert the display to °C.

In the case of all abovementioned errors, a task that has been started can still be finished with the Temp Spray heating system switched off.

SPARE PARTS AND ACCESSORIES

ACCESSORIES

ACCESSORIES TEMPSPRA

POS. ORTDER-NO DESIGNATION
1 2368 269 AirCoat spray gun AC 4500 Proincl. blue aircap (for water diluted

ma- terials), holder and nozzle
2| 0344 905| Air hose 10m for AirCoat spray gun with TempSpray-H126
3| 0252 910| AirCoat-regulator add-on kit for Finish 270/250
4| 0340 250| AirCoat-regulator add-on kit for Superfinish units
5| 0097 201| Connecting piece A: 1/4“ I: M16x1.5
6| 9956 257| Personal protection switch (PRCD) 230V / 16A (to be installed by a skilled electrician)

VERVIEW OF TEMPSPRAY VERSIONS AND SPRAY PACKS

ORTDER-NO DESIGNATION
2311 659 TempSpray -H126 230V
2311 660 TempSpray -H226 230V
2311 661 TempSpray -H326 230V
**** 2311 8522311 8532311 854 Spraypacks: TempSpray -H126 TempSpray -H226

TempSpray -H326

SPARE PARTS LIST TEMPSPRAY-H326 / -H226

POS. ORTDER-NO DESIGNATION POS. ORTDER-NO DESIGNATION
1 9990 374 Handle M10 6 0252 455 Mini raster
2 9920 106 Washer A10.5 DIN 125 7 0367 561 Double-ended union
3 9903 347 Oval head screw M10x20 8 9984 458 Hose whip
4 2315 901 Hose guide assy. 9 9984 590 Hose whip assy.
5 2316 034 Roller guide assy. 10 9990 866 Rubber cap (2)

The number in brackets gives the total quantity of a component in the assembly.
The order number corresponds to one piece.
Therefore, please also specify the quantity 1 that you require when ordering.
TEMPSPRAY

TESTING OF THE UNIT

For safety reasons, we would recommend having the device checked by an expert as required but at least every 6 months to ensure that it can continue to operate safely.

In the case of unused devices, the check can be postponed until they are next started up.

All (potentially deviating) national inspection and maintenance regulations must also be observed.

If you have any questions, please contact the customer service team at Wagner.

IMPORTANT INFORMATION ON PRODUCT LIABILITY

According to an EU directive, the manufacturer is only liable without limitation for faults in the product if all parts come from the manufacturer or have been approved by the manufacturer and have been mounted to the device and are operated properly. If third-party accessories or spare parts are used, the manufacturer is exonerated wholly or partly from his/her liability if use of the third-party accessories or spare parts have caused a defect in the product. In extreme cases, the relevant authorities can completely prohibit using the entire device.

With original WAGNER accessories and spare parts, compliance with all safety regulations is guaranteed.

NOTE ON DISPOSAL

In observance of the European Directive 2002/96/EC on waste electrical and electronic equipment and implementation in accordance with national law, this product is not to be disposed of together with household waste material but must be recycled in an environmentally friendly way!

Wagner or one of our dealers will take back your used Wagner waste electrical or electronic equipment and will dispose of it for you in an environmentally friendly way. Please ask your local Wagner service centre or dealer for details or contact us direct.

3 + 2 YEAR GUARANTEE ON THIS WAGNER CONTRACTOR PRODUCT
(Status 03.03.2022)

WAGNER exclusively provides the commercial buyer who has purchased the product from an Authorised specialist dealer (hereinafter referred to as the „Customer“) with a guarantee for the products listed on the Internet at https://go.wagnergroup.com/3plus2-info in addition to the statutory warranty regulations, unless there is a guarantee exclusion.

The guarantee period for WAGNER products (devices) in the contractor‘s sector is 36 months and begins with the date of purchase of the initial purchase. This guarantee period is extended by a further 24 months if the product is registered within 28 days of purchase on the Internet at https://go.wagner- group.com/3plus2.

In cases of commercial rental, industrial use (e.g. use in shift operation) or equivalent use, the guarantee period is 12 months due to the significantly higher load. We reserve the right to carry out a check in individual cases and refuse the guarantee where necessary.

If any material, machining or performance defects are identified in the device within the guarantee period, then the guarantee claims must be made immediately and within a period of no more than 2 weeks following discovery of the defect.

The detailed guarantee conditions can be obtained on request from our authorised WAGNER partners (see website or operating instructions) or in text form on our website:

https://go.wagner-group.com/pf-warranty-conditions
QR Code

EU Declaration of conformity

We declare under sole responsibility that this product conforms to the following relevant stipulations:
2014/35/EU, 2014/30/EU, 2011/65/EU, 2012/19/EU

Applied harmonized norms:

EN 60204-1, EN 60519-1, EN IEC 61000-3-2,
EN 61000-3-3, EN IEC 61000-6-1, EN 61000-6-3

The EU declaration of conformity is enclosed with the product.

If required, it can be re-ordered using order number 2313841.

Part. No. 2312558 E
07/2023_RS
© Copyright by J.Wagner GmbH

Company logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Wagner User Manuals

Related Manuals