CENTURION Sector Ii Rectangular Boom Pole Joiner Instruction Manual
- June 14, 2024
- CENTURION
Table of Contents
CENTURION Sector Ii Rectangular Boom Pole Joiner
Company Profile
Sales and technical support to Africa, Europe, Asia, the Americas, Australia and the Pacific
Call Centre Operating Times
Monday to Friday
08h00 to 17h00 GMT+2,
Saturdays
08h00 to 14h00 GMT+2
Centurion Systems (Pty) Ltd reserves the right to make changes to the product
described in this manual without notice and without obligation to notify any
persons of any such revisions or changes.
Additionally, Centurion Systems (Pty) Ltd makes no representations or
warranties with respect to this manual. No part of this document may be
copied, stored in a retrieval system or transmitted in any form or by any
means electronic, mechanical, optical or photographic, without the express
prior written consent of Centurion Systems (Pty) Ltd.
Icons used in this manual
This icon indicates tips and other information that could be useful during the
installation.
This icon denotes variations and other aspects that should be considered
during installation.
This icon indicates warning, caution or attention! Please take special note of
critical aspects that MUST be adhered to in order to prevent injury.
Introduction
ATTENTION!
To ensure the safety of people and possessions, it is important that you read
all of the following instructions.
Incorrect installation or incorrect use of the product could cause serious
harm to people.
The installer, being either professional or DIY, is the last person on the
site who can ensure that the operator is safely installed and that the whole
system can be operated safely.
Warnings for the Installer
CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before installing the product.
- All installation, repair, and service work to this product must be carried out by a suitably qualified person
- Do not activate your barrier unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions
- NO ONE MAY CROSS THE PATH OF A MOVING BARRIER. Always keep people and objects away from the barrier and its area of travel
- NEVER LET CHILDREN OPERATE OR PLAY WITH THE BARRIER CONTROLS
- Secure all easily-accessed barrier controls in order to prevent unauthorised use of the barrier
- Do not in any way modify the components of the automated system
- Do not install the equipment in an explosive atmosphere: the presence of flammable gasses or fumes is a serious danger to safety
- Before attempting any work on the system, cut electrical power to the operator and disconnect the batteries
- The mains power supply of the automated system must be fitted with an all-pole switch with contact opening distance of 3mm or greater. Use of a 5A thermal breaker with all-pole circuit break is recommended
- Make sure that an earth leakage circuit breaker with a threshold of 30mA is fitted upstream of the system
- Never short-circuit the battery and do not try to recharge the batteries with power supply units other than that supplied with the product, or manufactured by Centurion Systems (Pty) Ltd
- Make sure that the earthing system is correctly constructed, and that all metal parts of the system are suitably earthed.
- Safety devices must be fitted to the installation to guard against mechanical movement risks, such as crushing, dragging and shearing
- It is recommended that at least one warning indicator light be fitted to every system
- Always fit the warning signs visibly to the inside and outside of the barrier
- The installer must explain and demonstrate the manual operation of the barrier in case of an emergency, and must hand over the user guide to the user
- Explain these safety instructions to all persons authorised to use this barrier, and be sure that they understand the hazards associated with traffic barriers
- Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger
- Dispose of all waste products like packing materials, worn-out batteries, etc. according to local regulations
- Always check the obstruction detection system and safety devices for correct operation
- Neither Centurion Systems (Pty) Ltd, nor its subsidiaries, accepts any liability caused by improper use of the product, or for use other than that for which the automated system was intended
- This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of danger
- Anything that has not been specified in these instructions may be considered a risk to your safety, and the safety of others. If you are unsure of an installation matter, please contact your nearest distributor
WARNING!
**SAFETY FIRST
** MOVING BARRIER CAN CAUSE SERIOUS INJURY OR DEATH!
KEEP AWAY! THE BARRIER MAY MOVE AT ANY TIME! DO NOT ALLOW CHILDREN TO PLAY IN
THE AREA OR OPERATE THE BARRIER.
Product Identification
External components
- Rectangular Boom pole (3m, 4.5m and 6m) (not supplied)
- Boom pole Shroud frame
- Boom pole Shroud
- Rectangular Boom pole retainer
- Rectangular coupler
- Rectangular breakaway coupler
- Door
- Barrier enclosure
- Manual override (6mm Allen key)
- Barrier lid
Hardware unpacking
- M8 threaded rod
- Rectangular boom pole joiner
- M10 washer
- M8 connector cap
Physical Installation
Fitting the rectangular boom pole joiner
The following steps should be performed with the rectangular boom pole
removed from the SECTOR II, for ease of drilling.
-
After cutting your boom poles to size, measure 15mm and 165mm from the edge of the end of your first boom pole.
-
Mark and centre punch the hole positions for drilling.
-
Repeat step 1 and step 2 on the opposite end of your second boom pole.
-
Mark and centre punch the same hole positions on the other side of both your boom poles.
Keep note of orientation.
Plastic bumper must be facing downwards.
-
Drill two 10mm holes on both sides of each boom pole.
-
Slide the Joiner into the boom pole and align all four holes.
-
Fasten the Joiner to the boom pole using the M8 threaded rods and connector caps.
-
Slide the other end of the Joiner into the other boom pole and align all four holes.
-
Fasten the Joiner to the boom pole using the M8 threaded rods and connector caps.
Installation Handover
Once the SECTOR II rectangular boom pole joiner has been successfully installed and its operation tested, it is important for the operation and safety considerations to be explained to the end-user of the system.
CUSTOMER SERVICES
Connect with us on:
facebook.com/centurionsystems
YouTube.com/centurionsystems
@askcenturion
centurion.systems
Subscribe to the newsletter:
www.centsys.com/subscribe
Call Centurion Systems (Pty) Ltd . South Africa
Head Office: +27 11 699 2400
Call Technical Support: +27 11 699 2481
Monday to Friday: from 08h00 to 17h00 (GMT+2)
Saturday: from 08h00 to 14h00 (GMT+2)
E&OE Centurion Systems (Pty) Ltd reserves the right to change any product
without prior notice All product and brand names in this document that are
accompanied by the ® symbol are registered trademarks in South Africa and/or
other countries, in favour of Centurion Systems (Pty) Ltd, South Africa. The
CENTURION and CENTSYS logos, all product and brand names in this document that
are accompanied by the TM symbol are trademarks of Centurion Systems (Pty)
Ltd, in South Africa and other territories; all rights are reserved. We invite
you to contact us for further details.
Doc number: 1246.D.01.0015_21022023
www.centsys.com
Centurion Systems (Pty) Ltd
www.centsys.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>