PCE-555BT Environmental Meter User Manual

June 4, 2024
PCE

PCE-555BT Environmental Meter

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual.

We expressly point to our general guarantee terms which can be found in our general terms of business.

If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Specifications

Measuring function| Measurement range| Resolution| Accuracy
---|---|---|---
Humidity| 0 … 100 % RH| 0.1 % RH| ±3.5 % RH at 20 … 80 % RH
Remaining range ±5 % RH
Temperature| -20 … 60 °C
-4 … 140 °F| 0.1 °C
0.1 °F| ±0.5 °C / 0.9 °F at 0 … 40 °C
Remaining range ±1 °C / 1.8 °F
Wet bulb temperature| 0 … 60 °C
32 … 140 °F| 0.1 °C
0.1 °F| ±0.5 °C / 0.9 °F at 0 … 40 °C
Remaining range ±1 °C / 1.8 °F
Dew point temperature| -20 … 60 °C
-4 … 140 °F| 0.1 °C
0.1 °F| ±0.5 °C / 0.9 °F at 0 … 40 °C
Remaining range ±1 °C / 1.8 °F
Further specifications|
Display| LC display with backlight
Interface| Bluetooth
Bracket| 3/8″ tripod thread
Automatic power off| after 15 minutes of inactivity (can be disabled)
Operating conditions| 0 … 50 °C (32 … 122 °F), <80 % RH, non condensing
Storage conditions| -20 … 60 °C (-4 … 140 °F), <80 % RH,

non condensing

Power supply| 9 V block battery
Dimensions| 204 x 54 x 36 mm
Weight| 172 g

Delivery scope
  • 1 x PCE-555BT environmental meter
  • 1 x 9 V block battery
  • 1 x user manual

Device description

No. Description
1 Temperature and humidity sensor
2 Display
3 HOLD key: freeze measured value / backlight
4 MAX/MIN key
5 On/off switch
6 Function and unit change key
7 Bluetooth on/off switch

Switching on and off

To switch the meter on and off again, press and release the on/off switch once.

Automatic power off

When switched on, the automatic power off function is activated. The meter thus switches off after 15 minutes. To disable automatic power off, press and hold the on/off key for at least two seconds while the meter is switched on.

Backlight

To switch the backlight on and off, press and hold the HOLD key for at least two seconds.

Temperature measurement

To select between the individual temperature functions, repeatedly press the function change key until you have reached your desired temperature measurement function. You can choose:

[No display] Temperature
“WB” Wet bulb temperature
“DP” Dew point temperature
Set temperature unit

To set the temperature unit, press and hold the unit change key for at least two seconds. You can switch between °C and °F.

MAX / MIN

In addition to normal measuring mode in which the current measured value is always displayed, the largest and smallest measured value can also be displayed. To do this, repeatedly press the MAX/MIN key until you have reached your desired function. When “MAX” is displayed, only the largest measured value is shown. When “MIN” is displayed, only the smallest measured value is displayed. If you switch between the individual functions, the previous function is reset. The values are therefore not retained.

Freeze measured value

To hold the displayed reading, press the HOLD key once. To resume the measurement, press the HOLD key again.

Bluetooth

To establish a Bluetooth connection with a mobile device, press and hold the Bluetooth on/off key for at least two seconds to switch on the Bluetooth function. To switch off this function, press and hold this key again. As soon as you switch off the meter, the Bluetooth function is disabled. With the following QR codes you can download the compatible app “Meterbox Pro”:

Android Apple

Battery information

As soon as the battery voltage is less than 7.2 V, the battery icon is displayed. The battery should now be changed to ensure proper measurement. If the battery voltage is below 6.5 V, the backlight and the battery icon flash twice. The meter then switches off.

Replace battery

To replace the battery, first switch off the meter. Now open the battery compartment on the back. Then replace the 9 V block battery with a new one. Finally, close the battery compartment. The meter is then ready for use again.

Warranty

You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.

PCE Instruments contact information

Germany
PCE Deutschland GmbH
Im Langel 4
D-59872 Meschede

Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29 info@pce-instruments.com
www.pce-instruments.com/deutsch

United Kingdom
PCE Instruments UK Ltd
Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
info@pce-instruments.co.uk
www.pce-instruments.com/english

The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
info@pcebenelux.nl
www.pce-instruments.com/dutch

France
PCE Instruments France EURL
23, rue de Strasbourg
67250 Soultz-Sous-Forets
France
Téléphone: +33 (0) 972 3537 17
Numéro de fax: +33 (0) 972 3537 18
info@pce-france.fr
www.pce-instruments.com/french

Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano
Capannori (Lucca)
Italia
Telefono: +39 0583 975 114
Fax: +39 0583 974 824
info@pce-italia.it
www.pce-instruments.com/italiano

Hong Kong
PCE Instruments HK Ltd.
Unit J, 21/F., COS Centre
56 Tsun Yip Street
Kwun Tong
Kowloon, Hong Kong
Tel: +852-301-84912
jyi@pce-instruments.com
www.pce-instruments.cn

Spain
PCE Ibérica S.L.
Calle Mayor, 53
02500 Tobarra (Albacete)

España
Tel. : +34 967 543 548
Fax: +34 967 543 542
info@pce-iberica.es
www.pce-instruments.com/espanol

Turkey
PCE Teknik Cihazları Ltd.Şti. Halkalı Merkez Mah.
Pehlivan Sok. No.6/C
34303 Küçükçekmece – İstanbul Türkiye
Tel: 0212 471 11 47
Faks: 0212 705 53 93
info@pce-cihazlari.com.tr
www.pce-instruments.com/turkish

United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach
33458 FL

USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
info@pce-americas.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals