TRANE BAYHTR16 Supplementary Electric Heater Installation Guide
- June 14, 2024
- Trane
Table of Contents
TRANE BAYHTR16 Supplementary Electric Heater Installation Guide
SAFETY
WARNING may cause personal death or serious injury.
CAUTION may lead to injury or structural damage under some conditions
WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING
INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE.
FAILURE TO DO THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY.
WARNING
FIBERGLASS WOOL EXPOSURE!
REFER TO OWNER’S INFORMATION MANUAL PROVIDED WITH THIS UNIT FOR PROPER
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS.
DISTURBING THE INSULATION IN THIS PRODUCT DURING INSTALLATION, MAINTENANCE OR REPAIR WILL EXPOSE YOU TO AIRBORNE PARTICLES OF GLASS WOOL FIBERS AND CERAMIC FIBERS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER THROUGH INHALATION. GLASS WOOL FIBERS COULD ALSO CAUSE RESPIRATORY, SKIN OR EYE IRRITATION.
WARNING
FIRE HAZARD!
WITH HEAT PUMP INSTALLATIONS, SOME ELECTRIC HEATERS ARE POSITION SENSITIVE.
USE ONlY APPROVED HEATER TO UNIT COMBINATIONS PER NAMEPLATE AND SET BLOWER
AIRFLOW SPEED PER NAMEPLATE INSTRUCTIONS.
WHEN HEATERS COME SUPPLIED WITH CIRCUIT BREAKERS, USE 240/208 VOLT SUPPLY POWER WITH 120 VOLTS (NOMINAL) TO GROUND.
FAILURE TO FOLLOW THE ABOVE COULD RESULT IN DEATH, SERIOUS INJURY OR EQUIPMENT DAMAGE.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During installation or repair, caution is to be observed It is your responsibility to install the product safely and to educate the customer on its safe use
Electrical Data
Table 1. Electrical data
Model
Number| Voltage-Phase-Hz| Power Supply
Wiring Gauge| Motor HP| Motor Steps| Minimum Circuit
AMPS| Fuse (A)
---|---|---|---|---|---|---
E4AH5E24A1J30A| 208/230-1Ph-60Hz| 14| 1/3| 5| 3.0| 15
E4AH5E36A1J30A| 1/2| 5.2
E4AH5E48A1K30A| 3/4| 7.5
E4AH5E60A1K30A| 3/4| 7.5
Electric Heat Data
Table 2. Electric heat data
Kit Model| Model Number| Electric
Heat (kW)| MIN. Circuit Ampacity| MAX. Fuse orBreaker (HACR)
Ampacity| Fans peed
---|---|---|---|---|---
208| 230| 208| 230| 1| 2| 3| 4| 5
BAYHTR1605BRKA| E4AH5E 24A1J30A| 5| 23| 25| 25| 30| x| x| •| •| •
BAYHTR1610BRKA| 10| 45| 50| 50| 60| x| x| •| •| •
BAYHTR1605BRKA| E4AH5E 36A1J30A| 5| 23| 25| 25| 30| x| x| •| •| •
BAYHTR1610BRKA| 10| 45| 50| 50| 60| x| x| •| ‘| 6
BAYHTR1615BRKA| 5+10| 23+45| 25+50| 50+25| 60+30| x| x| •| •| •
BAYHTR1605BRKA| E4AH5E 48A1K30A| 5| 23| 25| 25| 30| x| x| •| •| •
BAYHTR1610BRKA| 10| 45| 50| 50| 60| x| x| •| •| •
BAYHTR1615BRKA| 5+10| 23+45| 25+50| 50+25| 60+30| x| x| •| •| •
BAYHTR1620BRKA| 10+10| 45+45| 50+50| 50+50| 60+60| x| x| x| .| .
BAYHTR1605BRKA| E4AH5E 60A1K30A| 5| 23| 25| 25| 30| x| x| •| •| •
BAYHTR1610BRKA| 10| 45| 50| 50| 60| x| x| •| •| •
BAYHTR1615BRKA| 5+10| 23+45| 25+50| 50+25| 60+30| x| x| .| .| .
BAYHTR1620BRKA| 10+10| 45+45| 50+50| 50+50| 60+60| x| x| x| ‘| ‘
MCA and Max Fuse Ampacity contains the motor amps.
Electric heat kits are suitable for air handler multiple position installation. means available means unavailable.
Safety Cautions All electric work must be performed by qualified personnel
BAYHTR 16** series is designed and approved to be installed in the AMERISTAR or RUNTRU series air handlers.
- Check the BAYREUTH* label confirm BAYREUTH size based on room load under lowest ambient temperature.
- Inspect all heating elements and whether heater element wires. Contact local whether heater element wires. Contact local if there is any occurred damage.
Warning
- Disconnect all external power supplies before performing installation and servicing. Turn off accessory heater power switch if applicable. Failure to do so may cause serious injury.
- BAYHTR16** must be properly grounded and use copper supply wires.
- Make sure to follow national electric code and local regulations.
- When installing it in an enclosed area such as a garage, heater elements should have a minimum clearance of 18” from the floor to insure the proper ventilation.
Available electric auxiliary heater
When unit is installed with electric auxiliary heater, the fan speed selection must meet the following static pressure requirements, and the gray boxes part is not allowed to use electric auxiliary heating.
Model| Motor
Speed| Available electric auxiliary heater
---|---|---
External Static Pressure-Inches W.C.[Psi]
0| 0.1| 0.16| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
[0]| [.003]| [.023]| [029]| [.044]| [.058]| [.072]| [.087]| [.102]| [.116]
E4AH5E24A1J30A| Tap (5)| 5-10kW
Tap (4)| 5-1040,,,/
Tap (3)| 5-10k \N
Tap (2)| a
Tap (1)| aa
E4AH5E36A1J30A| Tap (5)| 5-15kW
Tap (4)| 5-15kW
Tap (3)| 5-15kW
Tap (2)|
Tap (1)| A
E4AH5E48A1J30A| Tap (5)| 5-20kW
Tap (4)| 5-20kW
Tap (3)| 5-15kW
Tap (2)|
Tap (1)| I
E4AH5E60A1J30A| Tap (5)| 5-20kW
Tap (4)| 5-20kW
Tap (3)| 5-1540,Al
Tap (2)|
Tap (1)|
INSTALLATION INSTRUCTIONS “BAYHTR16”**
Heater Kits For use in Air Handlers ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this installation manual. Observe all safety warnings. During installation or repair, caution is to be observed. It is your responsibility to install the product safely and to educate the customer on its safe use.
STEP 1. Unfasten 4 screws to take away the blower access panel of the air handler.
STEP 2.Remove the cover plate from the air handler.
STEP 3.Slide the heater kit into the slot and secure element plate with previously removed screws.
When sliding the heater kit into the slot ensure that it is installed in the correct orientation described below. Thermostat will be on the left hand side and the fuse will be on the right hand side.
When two elements are being used ensure that “UPPER” and “LOWER” elements are installed in the correct slots and orientations.
STEP 4. Align the attachment clip and the hole and fasten the loose wires by using wire tie.
STEP 5. Install the circuit breaker into the mounting rail, break out appropriate area of the plastic circuit breaker cover on the access panel of the air handler.
WARNING
FIRE, ELECTRICAL SHOCK, HAZARD
After connecting all wires, check all screws of breaker and make sure all screws are properly tight.
Failure to do so will result in breaker malfunction,fire, death, personal injury and properly damage.
NOTE:
- When indoor control board receives W1/W2 signal, electric heater will be energized and indoor blower will be turned on.
- When W1/W2 signal is off, indoor blower will be turned off. Blower motor runs when is energized, and off when is de-energized
Figure 4-3 Wiring diagram for 5KW electric heat
**Figure 4-4 Wiring diagram for 10KW electric heat
**
Figure 4-5 Wiring diagram for 15KW electric heat
**Figure 4- Wiring diagram for 20KW electric heat
**
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential
applications. For more information, please visit
www.trane.com or
www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
88-MACC025-1C-EN 08 Jun 2023
Supersedes 88-MACC025-1B-EN (27 Apr 2023)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>