JVD EXP’AIR+ Hand Dryer Instruction Manual

June 14, 2024
JVD

JVD EXP’AIR+ Hand Dryer

IMPORTANT SAFETY PRECAUTIONS

  • Never attempt to install the appliance yourself, unless you are a suitable qualified technician. Doing so may affect its operation and safety

  • This appliance must be installed by a qualified technician. Incorrect electrical connections can result in electrocution or short circuits.

  • Means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III condi-tions must be incorporated in the fixed wiring in accordance with the wiring rules

  • For additional protection, the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30 mA is advisable in the electrical circuit supplying the bathroom. Ask your installer for advice.

  • Never take off the appliance when it is connected.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard

  • Do not connect any other appliances on the same line. It may result in overheating and fire

  • Before use, ensure the rated voltage indicated on the appliance match the supply voltage.

  • Only use this hand dryer to dry your hands.

  • WARNING: Do not use this appliance near bathtubs, showers, basins or other vessels containing
    water.

  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.

  • Children shall not play with the appliance.

  • Do not allow children to hang from the appliance, as it may become detached from its support.

  • Cleaning and user maintenance shall not be done by children without supervision.

  • Disconnect the appliance before inspecting or clea-ning it.

  • Always use the appliance with its receptacle and air filters. Otherwise, water may enter the appliance, resulting in a short circuit or electrocution.

INSTALLATION

This appliance is designed to be used in commercial areas

CAUTION

  • Never attempt to install the appliance yourself, unless you are a suitably qualified technician. Doing so may affect its operation and safety.
  • Do not install the appliance when it is connected.
  • Install the appliance on a support that is sufficiently solid to attach it securely.

Precautions before installing the appliance
Do not install the appliance in places with the following characteristics:

  • Temperature lower than –10° or higher than +40°C.
  • Places where the appliance may come into direct contact with water.
  • Places exposed to severe condensation.
  • Places where corrosive or neutral gases are present.
  • At less than 20m or more than 2000m above sea level.

Information for installation

  • Use a monophase AC current of 220V-240V / 50 Hz.
  • Use a power supply cable with conductors with a cross-section of 2.5mm².
  • Leave at least 15cm free on either side to access the filters.
  • Avoid places where the appliance could be hit by a door.
  • Install the appliance on a perfectly flat wall.
  • Allow for the power supply cable inlet.
  • Find out the dimensions and space requirements of the product before installing it.

Dimensions

JVD-EXP-AIR-Hand-Dryer-fig-1

Space requirements and installation constraints

JVD-EXP-AIR-Hand-Dryer-fig-2

Installation procedure

Attaching the metal wall support plate

  1. Mount the wall support plate at the required height. The recommended height is between 90 and 110cm.
  2. Provide a wall cable outlet that is adapted to the height of the appliance.
  3. Prepare the attachment holes in the lower part of the appliance (drilling template on).JVD-EXP-AIR-Hand-Dryer-fig-3

Preparing the appliance
Removing the tank:

  1. Insert the key in the hole under the appliance.
  2. Pull the tank forward. Remove the cover.
  3. The cover is not screwed in place when delivered. Remove the cover by pulling forwards.JVD-EXP-AIR-Hand-Dryer-fig-4

Drilling template

JVD-EXP-AIR-Hand-Dryer-fig-5

Mounting the appliance on the wall

  1. Open the class II cover.
  2. Pass the power supply cable through the hole and towards the front.
  3. Mount the appliance on the support plate.
  4. Secure the base of the product.

Connection to the terminal strip

  1. Install and tighten the cable clamp. Adjust the length of the power supply wires.
  2. Connect the two power supply wires to the terminal strip.JVD-EXP-AIR-Hand-Dryer-fig-7

End of the installation

  1. Close the class II cover.
  2. Install the cover. Tighten the four screws.
  3. Install the tank.JVD-EXP-AIR-Hand-Dryer-fig-8

OPTION: Connection to the drainage

  1. Make one hole in the tank meant for the discharge- ø: 12mm
  2. Install the spillway
  3. You can realize the junction with the sluice (Think of installing a trap to avoid bad odours)JVD-EXP-AIR-Hand-Dryer-fig-9

USE

  • Place both hands inside the ring. The drier starts automatically.

JVD-EXP-AIR-Hand-Dryer-fig-10

  • Slowly remove both hands as the air flow drives the water off your skin.
  • Completely remove your hands.This takes between 10 and 15 seconds. The appliance stops automatically.JVD-EXP-AIR-Hand-Dryer-fig-11

INDICATOR LIGHTS

  • When the product is switched on, the indicators LEDs in the ring indicate that it is working properly. If the lights are off, the appliance is off too.

Initialisation of the PCB.
For 10 seconds after the appliance is switched on, the status of the LEDs indicates that the detection system is being initialised. Do not use the appliance during this period.

Detection problem:
The motor cuts out for 60 seconds, after 5 minutes seconds of continuous detection. The LED on the far right flashes quickly. After 15 repeated cycles, the motor cuts out and the LED flashes slowly. Disconnect the appliance.

MAINTENANCE

Before any maintenance or cleaning operations, switch off the appliance with the circuit breaker on the electrical panel. All maintenance and cleaning operations must be carried by qualified technicians.

Emptying and cleaning the tank each day

  1. Empty and clean the water recovery tank before it is full (at least once a week) to avoid foul smells. If the tank is not regularly emptied and cleaned, a red LED indicates that the tank is full.
  2. To remove the tank, insert the key in the hole under the appliance. Pull the tank forward.
  3. Remove the cover.
  4. Empty the tank.
  5. Clean the tank (you can use cleaning products).
  6. Close the cover.
  7. Install the tank.JVD-EXP-AIR-Hand-Dryer-fig-14

REPLACEMENT PARTS: It is possible to replace the cover, the tank, the filter and filter support by a qualified technician. The rest of the parts must be replaced by the manufacturer.

  1. Routine cleaning of the air filter each week
  2. Pull the 2 filter holder modules using the tab
  3. Remove the 2 filters
  4. Vacuum the 2 filters by rubbing them with a brush to remove the dust
  5. Put back the 2 filter holders till the clipJVD-EXP-AIR-Hand-Dryer-fig-15

Detailed cleaning of copper filters each month Remove the 2 filters as in paragraph 2 (above)

  1. Vacuum the 2 filters by rubbing them with a brush to remove the dust
  2. Place them in a small pan (or a kettle) and boil them with a soupspoon of citric acid, vinegar or salt. Then put back the dry filters in the device.

Cleaning the exhaust system each week
Regularly clean the interior of the exhaust system using the rifle-type brush (provided in the package). It is recommended to carry out this operation every time the reservoir is drained.JVD-EXP-AIR-Hand-Dryer-
fig-17

CHARACTERISTICS

  • Supply voltage: 220-240 V
  • Frequency: 50-60 Hz
  • Nominal power: EXPAIR: 800 W (Brush motor) No heating resistor Class II – IP 44 product Electronic safety device in event of malfunction Capacitive detection system
  • Capacity of the tank: 600 ml (Tank secured by lock and key)
  • Noise level: 75.5 dBA 2 antibacterial air filters that are readily accessible for easy cleaning
  • Toral weight: 7 kg

If any parts show signs of abnormal wear, please contact After-Sales. In case of an accident, malfunctioning or blockage of the appliance, disconnect the appliance from the power supply but never attempt to repair the appliance yourself, unless you are a suitably qualified technician. A faulty connection or any damage resulting from wrongly usage or which is in contradiction to the instructions in this leaflet will render the guarantee void. This equipment complies with the regulations in European directives 2014/35/UE, 2014/30/UE and 2011/65/EC

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals