Miele PFD 102 i Stainless Steel Dishwasher Installation Guide
- June 4, 2024
- Miele
Table of Contents
PFD 102 i
PFD 103 SCi
Installation plan
M.-Nr. 11 673 370
Installation notes
Installation notes
For safe installation and commissioning of the dishwasher please read the
installation plan, the service documentation, the installation sheet, and the
operating instructions.
This installation plan includes the dimensions of the appliance, the technical
data, and the requirements to be met on site for the installation of the
dishwasher.
Installation requirements| This dishwasher must only be installed and
commissioned by the Miele Customer Service Department, a Miele authorized
dealer or a suitably qualified specialist.
Installation should only be performed in accordance with valid regulations,
relevant standards and health and safety codes.
---|---
Environmental requirements| Condensate can build up in the area surrounding
the dishwasher. Any furniture and fittings in the room must therefore be
suitable for purpose.
Vapour barrier film for built-in appliances| The vapour barrier film supplied
protects the worktop from damage caused by steam when the door is opened.
Attach the vapour barrier film above the door, underneath the worktop.
Electrical connection| All work on the electrical connection must be carried
out by the Miele Customer Service Department, an authorised Miele dealer or a
qualified electrician.
Plug connection| The dishwasher should be connected to the electricity supply
via a
suitably rated plug and socket.
Hard-wired| If the dishwasher is hard-wired to the power supply, a power
switch capable of disconnecting the dishwasher at all poles must be installed
on-site. This power switch must have a contact gap of at least 3 mm.
The socket and the power switch must be accessible after the appliance has
been installed. An electrical safety test can then easily be carried out,
e.g., after any service or maintenance work. The connection cable must be
protected from the risk of thermal damage.
Residual current device (RCD)| For increased safety, it is recommended to
protect the dishwasher with a residual current device (RCD) with a trip
current of 30 mA.
Equipotential bonding| There is a screw connection point for equipotential
bonding at the back of the dishwasher.
Equipotential bonding should be carried out if possible on site.
Water connection| The dishwasher must only be connected to fully vented
pipework. A brief increase in the water pressure can damage components of the
dishwasher.
Water inlet| The quality of the incoming water must correspond to the drinking
water specification of the country in which the dishwasher is being operated.
The dishwasher must be connected to the water supply in strict accordance with
current local and national water authority regulations. It can be connected to
cold or hot water supplies. Connecting the dishwasher to a hot water supply
will reduce program running times. For short program running times, the
dynamic water pressure of at least 200 kPa is also required. UK installation
requirements: The double check valve supplied with this product must be
installed between the stopcock and the water inlet hose. Screw the double-
check valve onto the stopcock. Then screw the water inlet hose with the water
protection system onto the thread of the double-check valve. If a stopcock is
not available, only a qualified installer may connect the dishwasher to the
mains water supply. The stopcock should remain accessible once the dishwasher
has been installed so that the water supply can be shut off whenever the
appliance is not in use.
Drain| The dishwasher drain hose should be connected to a separate on-site
drainage system for the dishwasher only. If a separate connection is not
available, we recommend connecting the hose to a dual-chamber siphon.
If the hose is to be fitted directly to the drainage system on site, use the
hose clip supplied with the dishwasher.
The on-site connector for the drain hose can be adapted to different hose
diameters. If the connector extends more than 30 mm into the drain hose, it
must be shortened. Otherwise, the drain hose can become blocked. Lay the drain
hose so that it does not kink and is not being subjected to pressure or
tension.
If the on-site drain connection is situated lower than the guide path for the
lower basket rollers in the open door, a siphoning effect during a programme
can cause the wash cabinet to empty itself of water. In this case, lay the
drain hose with a bend in it so that its highest point is at least level with
the guide path for the lower basket
rollers.
External dispensing| An external dispensing module for liquid cleaning agents
can be connected to the back of the dishwasher.
The dispensing module is available as an optional accessory and is supplied
with installation instructions.
Appliance dimensions and installation dimensions
Appliance dimensions and installation drawings
Appliance type | PFD 102 i | PFD 103 SCi |
---|
Front panel dimensions
Length | [mm] | 500–654 | 540–694 |
---|---|---|---|
Thickness | [mm] | 16–20 | 16–20 |
Weight | [kg] | 4–11 | 4–11 |
Connections
Connections on the back of the appliance
- Electrical connection
- External dispensing, power supply connection
- Equipotential bonding
- Wastewater
- Cold or hot water
- External dispensing, connection for dispensing hose sealed with a blind stopper*
- the dispenser connector is supplied with the dispensing module
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of the appliance to DOS module | [m] | 2.8 |
Length of power cable, back of the appliance to DOS module | [m] | 2.8 |
Place the container on the floor next to the cleaning machine or in an
adjacent cabinet.
The container must not be placed on top of or above the cleaning machine.
Technical data
Appliance type | PFD 102 i | PFD 103 SCi |
---|
Dimensions and weights
Height| [mm]| 805| 845
Height adjustment| [mm]| 65| 65
Width| [mm]| 598| 598
Depth| [mm]| 570| 570
Depth with door open| [mm]| 1165| 1205
Max. plinth return| [mm]| 115| 115
Weight| [kg]| 42| 52
Max. floor load| [N]| 1000| 1000
Emission levels
Sound power level | [dB(A) re 1 pW] | 46 | 45 |
---|---|---|---|
Sound pressure level in the workplace | [dB(A)] | 34.1 | 32.5 |
Electrical connection
Standard electrical connection
Voltage | 3N AC 400 V |
---|---|
Frequency | [Hz] |
Fuse rating | [A] |
Plug | – |
Power cable length | [m] |
Power cable cross-section | [mm 2 ] |
Heat output | [kW] |
Total rated load | [kW] |
Possible voltage variant
Voltage * | AC 230 V |
---|---|
Frequency | [Hz] |
Fuse rating | [A] |
Plug | Typ-F |
Power cable ** length | [m] |
Power cable cross-section | [mm 2 ] |
Heat output | [kW] |
Total rated load | [kW] |
- Programme running times are longer with this voltage variant
** Optional accessory
Water inlet
Max. water temperature | [°C] | 60 |
---|---|---|
Max. water hardness | [mmol/l] | 6.5 |
Max. water hardness | [°dH] | 36 |
Water connection pressure | [kPa] | 50 – 1000 |
On-site threaded union (flat seal) | [inches] | 4-Mar |
Connection hose length | [m] | 1.5 |
Connection hose extension * | [m] | 1.5 |
* Optional accessory
Drain
Max. water temperature | [°C] | 82 |
---|---|---|
Drain hose length | [m] | 1.5 |
Max. drain hose length | [m] | 4 |
Max. delivery head | [m] | 1 |
Max. transient flow rate | [l/min] | 10 |
Hose inner diameter | [mm] | 22 |
On-site hose sleeve (**0** x length) |
[mm] | 22 x 30 |
Operating conditions
Ambient temperature | [°C] | +5 – +40 |
---|
Relative humidity:
Up to 31 °C, maximum
Linear decreasing to 40 °C| [%] [%]| 80
50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions
Ambient temperature | [°C] | -20 – +60 |
---|---|---|
Relative humidity | [%] | 10–85 |
Air pressure | [hPa] | 500–1060 |
Min. site access dimensions including transport pallet
Height| [mm]| 970
Width| [mm]| 670
Depth| [mm]| 670
Contact Service Commercial
Tél. : 01 49 39 44 44 –
Fax : 01 49 39 44 38 –
Mail : advpro@miele.fr
Contact SAV Professionnel (Intervention)| Tél. : 01 49 39 44 78 –
Fax. : 01 49 39 34 10 –
Mail : savpro@miele.fr
Contact Support Technique (Hotline)
Tél. : 01 49 39 44 88 – Mail :
support.technique@miele.fr
---|---
Ireland: Miele Ireland Ltd.
2024 Bianconi Avenue Citywest Business Campus Dublin 24
Tel: (01) 461 07 10,
Fax: (01) 461 07 97
Email: info@miele.ie, Internet:
www.miele.ie
Portugal: Miele Portuguesa, Lda.
Av. do Forte, 5, 2790-073 Carnaxide
Telf. 21 4248 100, Fax 21 4248 109
E-Mail: professional@miele.pt
Website: www.miele-professional.pt
Nederland: Miele Professional
De Limiet 2, Postbus 166, 4130 ED VIANEN Afdeling Customer Service
Professional
Tel.: (03 47) 37 88 84, Fax: (03 47) 37 84 29
E-mail: professional@miele.nl (verkoop &
algemene vragen)
E-mail: serviceprofessional@miele.nl
(service & onderhoud)
Website: www.miele-professional.nl
M.-Nr. 11 673 370 / 01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>