EK-Quantum Velocity2 DDC 4.2 PWM D-RGB-1700 Pump plus Water Block Combo Instructions
- June 4, 2024
- EK-Quantum
Table of Contents
- EK-Quantum Velocity2 DDC 4.2 PWM D-RGB-1700 Pump plus Water Block Combo
- GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY
- BOX CONTENTS
- WATER BLOCK DIMENSIONS
- TECHNICAL SPECIFICATIONS AND WATER BLOCK PARTS
- PREPARING THE MOTHERBOARD
- INSTALLING THE WATER BLOCK
- FITTINGS AND TUBING
- CONNECTING THE PUMP
- CONNECTING THE D-RGB LED STRIP
- SUPPORT AND SERVICE
- SOCIAL MEDIA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EK-Quantum Velocity2 DDC 4.2 PWM D-RGB-1700 Pump plus Water Block Combo
Please note the installation of the product is intended to be undertaken by an adequately trained and experienced person. You are installing the product at your own risk. If you are not properly trained or experienced or feel unsure about the installation procedure, please refrain from installing the product yourself and contact our tech support for assistance. We disclaim our liability for any damages to the product as well as incidental, consequential, or indirect damages incurred due to improper or inappropriate installation. Before you start using this product, please follow these basic guidelines: Please carefully read the manual before beginning the installation process. The EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O-ring gaskets. The use of corrosion inhibiting coolants is always recommended for liquid cooling systems, and mandatory for nickel-plated water blocks. Do not use pure distilled water! For best results, EK recommends the use of EK-Cryo Fuel coolants. Make sure to thoroughly bleed air out of your water block, or you will not reach optimal performance.
GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY
This CPU liquid cooling unit is pre-assembled for use with modern Intel desktop socket-type motherboards. By default (out of the box) this water block supports the following CPU sockets:
Intel LGA-1700
BOX CONTENTS
Mounting Mechanism – You may not need all the screws, mounting mechanism is universal!
WATER BLOCK DIMENSIONS
CPU WB:
Backplate:
TECHNICAL SPECIFICATIONS AND WATER BLOCK PARTS
Technical Specification
- Dimensions (LxHxW): 94.5 x 94.5 x 70.6
- D-RGB cable length: 500 mm
- D-RGB LED count: 14
- D-RGB connector standard 3-pin (+5V, Data, Blocked, Ground)
Position | EAN | Description | Quantity |
---|---|---|---|
1 | 105494 | Metal Plate | 1 |
2 | 105564 | M3 x 30 DIN7991 Screw | 3 |
3 | 8252 | M3 x 10 7991DIN Screw | 3 |
4 | 104028 | Coldplate (Nickel) | 1 |
5 | 104773 | OR for Coldplate | 1 |
6 | 104532 | Seeger ring | 4 |
7 | 100663 | EK Badge | 1 |
8 | 103952 | Mylar Sticker | 1 |
9 | 102642 | M4 x 35 DIN7991 Screw | 6 |
10 | 104029 | Jet Plate | 1 |
11 | 105490 | TOP Plate – Plexi | 1 |
12 | 105493 | Top plate – Brass | 1 |
13 | 105491 | Acetal Standout | 1 |
14 | 104650 | Backplate Assembly | 1 |
15 | 5183 | OR 45 x 1.5 | 1 |
16 | 5015 | OR 65 x 1.5 | 1 |
17 | 105766 | OR 11 x 1.5 | 1 |
18 | 5034 | OR 20 x 1.5 | 1 |
19 | 100500 | M4 x 12 DIN7991 Screw | 4 |
20 | 104774 | OR for TOP | 1 |
21 | 102639 | Quantum Plug Nickel | 4 |
22 | 104913 | Velocity2 Mounting Screw | 4 |
23 | 100747 | M3 x 10 mm 8 kg Spring | 4 |
24 | 3831109837580 | EK-DDC 4.2 PWM (12V SATA) | 1 |
25 | 103006 | LED Strip | 1 |
26 | 3830046996671 | Thermal PAD DDC | 1 |
PREPARING THE MOTHERBOARD
STEP 1
If already installed, please remove the motherboard from your computer and
place it on an even surface.
STEP 2
Cleaning the CPU: Wipe the IHS clean using a non-abrasive cloth or Q-tip
as shown in the illustration.
STEP 3
Applying thermal compound : Once clean, apply a line of Thermal Compound
on one edge of the IHS and use a credit card or similar to spread it evenly.
The layer of Thermal Compound must be thin and even in thickness over the
entire surface of the IHS. Excessive or irregular application may lead to poor
performance. This method works for Thermal Grizzly Hydronaut Thermal Compound
as supplied with all Velocity2 CPU Water Blocks.
INSTALLING THE WATER BLOCK
STEP 1
Unscrew the pre-installed Backplate on the CPU using an Allen Key 2.5 mm and
save it for the later steps.
STEP 2
Before placing the water block, it is mandatory to remove the protective foil
from the backside.
STEP 3
Position the CPU Water Block onto the Motherboard. Make sure to align the
holes (as shown in the picture).
Make sure to double check the layer of the Thermal Grease before placing the water block onto the motherboard.
STEP 4
After placing the water block, the stored backplate must be attached on the
backside of the motherboard using Allen Key 2.5 mm (shown in the picture).
Start fastening the backplate screws in a cross pattern. Do not tighten fully
until all of the nuts are partially screwed in. The Allen Key 2.5 mm must be
used in a standing position! Otherwise, the mounting screws may crack during
tighteening! EK recommends using the EK-Loop Torque Screwdriver – 0.6Nm :
https://www.ekwb.com/shop/ek-loop-torque-screwdriver-0-6nm
Make sure to orientate the backplate as illustrated. Incorrect installation of the backplate may result in damage to the motherboard.
FITTINGS AND TUBING
The EK-Quantum Velocity2 DDC 4.2 PWM D-RGB – 1700 water block has two options
of fitting placement. The TOP and the SIDE option as it’s shown on the
drawings.
It’s mandatory to use the top port as the INLET. Mixing the port may result in
poor thermal performance of the water block. Tighten the fittings in a
clockwise direction until the gasket underneath is compressed. The
installation of the EK-Quantum Velocity2 DDC 4.2 PWM D-RGB – 1700 water block
is now complete.
CONNECTING THE PUMP
The EK-DDC PWM has two connectors.
- SATA Connector: It must be connected directly to your PSU at times as it is used to power the pump.
- 4-pin PWM fan: It can be connected to your motherboard’s CPU_FAN or designated water pump hader. It can also be connected to a controller. This cable is used to control and report the rotational speed of the pump. If it’s not connected, the pump will run at the maximum speed (100% PWM).
CONNECTING THE D-RGB LED STRIP
STEP 1
Plug the 3-Pin connector from the water block’s D-RGB LED light to the DRGB
HEADER on the motherboard. The LED will work if the pin layout on the header
is as follows: +5V, Digital, empty, Ground. Please ensure that the arrow
indicated on the connector is plugged into the +5V line as indicated on your
motherboard. If you put the LED Diode to the 12V RGB HEADER you can damage the
LEDs. Failure to do so will damage your motherboard or LED strip.
SUPPORT AND SERVICE
In case you need assistance or wish to order spare parts or a new mounting
mechanism, please contact: https://www.ekwb.com/customer-support/
For spare parts orders, refer to the
page with “TECHNICAL SPECIFICATIONS AND WATER BLOCK PARTS” where you can find
the EAN number of each part you might need.
Include the EAN number with the quantity in your request. Mounting Mechanism
EAN can be found under “BOX CONTENTS” Thermal pads are readily available in
the EK shop
SOCIAL MEDIA
- EKWaterBlocks
- @EKWaterBlocks
- ekwaterblocks
- EKWBofficial
- ekwaterblocks