Remote Controller Specifications
Rated Voltage | 3.0V( Dry batteries RO3/LR03x2) |
---|---|
Signal Receiving Range | 8m |
Environment | -5°C~60°C(23°F~140°F) |
NOTE: For model of RG10Y 1(F/H/G/K)/BGEF, If the unit is turned off under
COOL, AUTO or DRY modewith the set temperature less than 24°C, the set
temperature will be automatically set to 24°C whenyou turn on the unit again.
If the unit is turned off under HEAT mode with the set temperature more than
24°C, the set temperature will be automatically set to 24°C when you turn on
the unit again.
Quick Start Guide NOT SURE WHAT A
FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions
sections of this manual for a detailed description of how to use your air
conditioner.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the
batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws
for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL
- The remote control must be used within 8 meters of the unit.
- The unit will beep when remote signal is received.
- Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used more than 2 months.
NOTES FOR USING REMOTE CONTROL
The device could comply with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B)
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by tuming the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to famil rize
yourself with its remote control. The following is a brief introduction to the
remote control itself. For instructions on how to operate your air
conditioner, refer to the How to Use Basic Functions section of this manual.
NOTE: For model
of RG10B(F1/H1/G1/K1)/BGEFU1 , press together & buttons at the same time for 3
seconds will altemate the temperature display between the °C & °F scale
Remote Screen Indicators
Information are displayed when the remote controller is power up. Note:
Allindicators shown in the figure are for the purpose of clear presentation.
But during the actaul operation, only the relative function signs are shown on
the display window.
How to Use Basic Functions
Basic operation
ATTENTION! Before operation, please ensure the unit is plugged in and
power is available.![Cooper Hunter LCD 1000 Remote Controller Air Conditioner
-
Indicators 1](https://manuals.plus/wp-content/uploads/2023/11/Cooper-Hunter- LCD-1000-Remote-Controller-Air-Conditioner-Indicators-1.png) COOL Mode
- Press the MODE button to select COOL. mode.
- Set your desired temperature using the TEMP or TEMP / button.
- Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
- Press the ON/OFF button to start the unit.
SETTING TEMPERATURE
The operating temperature range for units is 17-30°C (62-86°F)/20-28°C.
You can increase or decrease the set temperature in 1°C (1°F) increments.
AUTO Mode
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT
operation based on the set temperature.
- Press the MODE button to select AUTO.
- Set your desired temperature using the TEMP / or TEMP V button
- Press the ON/OFF button to start the unit.
NOTE: FAN SPEED can’t be set in AUTO mode. FAN Mode
- Press the MODE button to select FAN mode.
- Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
- Press the ON/OFF button to start the unit.
NOTE: You can’t set temperature in FAN mode.
As a resdult, your remote control’s LCD screen will not display temperature:
DRY Mode (dehumidifying)
- Press the MODE button to select DRY.
- Set your desired temperature using the TEMP or TEMP button
- Press the ON/OFF button to start the unit.
NOTE:FAN SPEED cannot be changed in DRY mode. HEAT Mode
- Press the MODE button to select HEAT mode.
- Set your desired temperature using the TEMP or TEMP button.
- Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
- Press the ON/OFF button to start the unit.
NOTE: As outdoor temperature drops, the performance of your unit’s HEAT
function may be affected. In such instances, we recommend using this air
conditioner in conjunction with other heating appliances.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically
turn on/off.
TIMER ON setting
NOTE:
- When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press’5 times to get 2.5, and press 10 times to gét 5h,) The timer will revert to 0.0 after 24.
- Cancel either function by setting its timer to 0.0h
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours
after the current time.
How to Use Advanced Functions
Swing function
Press Swing button
The horizontal louver will swing
up and down automatically when pressing Swing button Press again to make it
stop Keep pressing this button more than 2 seconds,the vertical louver swing
function is activated (Model dependent)
SHORTCUT function
Press SHORTCUT button Push this button when remote controller is on, the
system will automatically revert back to the previous settings including
operating mode, setting temperature, fan speed level and sleep feature (if
activated).
If pushing more than 2 seconds, the system will automatically restore the
current operation settings including operating mode, setting temperature, fan
speed level and sleep feature (if activated ).
TURBO Function
Press TURBO button When you select Turbo feature in COOL mode, the unit will
blow cool air with strongest wind setting to jump-start the cooling process.
When you select Turbo feature in HEAT mode, for units with Electric heat
elements, the Electric HEATER will activate and jump-start the heating
process.
Clean Function
Press CLEAN button Aitbome bacteria can grow in the moisture that condenses
around heat exchanger in the unit. With regular use, most of this moisture is
evaporated from the unit
By pressing the CLEAN button, your unit will clean itself automatically. After
cleaning, the unit will turn off automatically. Pressing the CLEAN button mid-
cycle will cancelthe operation and turn off the unit. You can use CLEAN as
often as you like.
Note: You can only activate this function in COOL or DRY mode
LED DISPLAY
Press this button to turn on and turn off the display on the indoor unit Keep
pressing this button more than 5 seconds, the indoor unit will display the
actual room temperature. Press more than 5 seconds again wil revert back to
display the setting temperature.
LOCK function Press together Clean button and Turbo button at the same
time more than 5 seconds to activate Lock function.
All buttons will not response except pressing these two buttons for two
seconds again to disable locking.
Silence function Keep pressing Fan button for more than 2 seconds to
activate/disable Silence function(some units)
Due to low frequency operation of compressor, it may result in insufficient
cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button
while operating will cancel silence function
FP function
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17°CI62°F or 20 °C(for model of RG10B10(F/H/G/K)/BGEF).
The unit will operate at
high fan speed (while compressor on) with temperature automatically set to
8°C/46°F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17 °CI62°F or 20 °C(for model RG10B10(F/H/G/K)/BGEF) to
activate FP function.Press On/Off, Sleep, Mode, Fan and Temp. button while
operating will cancel this function. The SLEEP function is used to decrease energy while
you sleep(and don’t need the same temperature settings to stay comfortable).
This function can only by activated via remote control For the details, please
see “sleep operation ” in * USER’S MANUAL ”
Note: The SLEEP function is not available in FAN or DRY mode.
SET function
- Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm
- To cancel the selected function, just perform the same procedures as above.
- Press the SET button to scroll through operation functions as follows: Fresh ( ) → Follow Me ( )→ AP mode( )
[]: If your remote controller has Fresh button, you can not use the SET button to select Fresh feature
FRESH function( ) (some units) :
When the FRESH function is initiated, the lonizer/Plasma Dust
Collector(depending on models) is energized and will help to remove pollen and
impurities from the air
Follow me function( ):
The FOLLOW ME function enables the remote control to measure the temperature
at its current location and send this signal to the air conditioner every 3
minutes interval. When using AUTO, COOL or HEAT modes, measuring ambient
temperature from the remote control(instead of from the indoor unit itself)
will enable the air conditioner to optimize the temperature around you and
ensure maximum comfort.
NOTE: Press and hold Turbo button for seven seconds to start/stop memory
feature of Follow Me function
- If the memory feature is activated,” On” displays for 3 seconds on the screen
- If the memory feature is stopped, “OF” displays for 3 seconds on the screen
- While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the Follow me function
AP function( )(some units) :
Choose AP mode to do wireless network configuration. For some units, it
doesn’t work by pressing the SET button. To enter the AP mode, continuously
press the LED button seven times in 10 seconds.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for
details.