Cooper Hunter Split Air Conditioner Nordic PREMIUM Series Owner’s Manual

June 12, 2024
Cooper Hunter

Cooper Hunter - logo

OWNER’S MANUAL
Split Air Conditioner
Nordic PREMIUM Series

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series
-

MODELS:
CH-S09FTXN-PW CH-S12FTXN-PW
CH-S18FTXN-PW CH-S24FTXN-PW
CH-S09FTXN-PS CH-S12FTXN-PS
CH-S09FTXN-PB CH-S12FTXN-PB
CH-S18FTXN-PB CH-S24FTXN-PB

Split Air Conditioner Nordic PREMIUM Series

For proper operation, please read and keep this manual carefully.

| Appliance filled with flammable gas R32.
---|---
| Before use the appliance, read the owner’s manual first.
| Before install the appliance, read the installation manual first.
| Before repair the appliance, read the service manual first.

The Refrigerant

  • To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fluoride R32, which is specially cleaned.
    The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion under certain conditions. But the flammability of the refrigerant is very low. It can be ignited only by fire.

  • Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efficiency. The units therefore need a less filling.

WARNING
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. Should repair be necessary, contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance shall be stored in a room without continuously operating ignition sources. (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn. Appliance shall be installed, operated and stored in a room with a floor area larger than Xm .(Please refer to table “a” in section of ” Safety Operation of Inflammable Refrigerant” for Space X.)
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s instructions only. Be aware that refrigrants not contain odour. Read specialist’s manual.

IMPORTANT INFORMATION

Is intended for dehydration of air in domestic premises the appliance is designed for air cooling in domestic premises. The manufacturer reserves the right to introduce changes in design, configuration and processing of the article with a view to improve its properties without any prior notification of customers. There may be some misprints in text and digital notations of the present manual. If after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations.
The article has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purpose indicated in this manual.

SAFEGUARDS

  1. Don’t try to install the conditioner by yourself. Call for a qualified installation specialist.
  2. While using the air conditioner, it is necessary to observe several precautions. Incorrect operation due to ignoring of precautions may result in personal injury of a user and other people, as well as in damaging of their property.
  3. The electric appliance should be under observation while operated, especially if there are any children near it.
  4. Don’t pass your fingers or foreign objects through an air outlet grille of indoor and outdoor units, since it may result in a trauma caused by a revolving fan.
  5. Don’t let children turn the conditioner on by themselves. Children may turn the conditioner on only under the care of adults.
  6. Don’t try to repair the conditioner by yourself. Internal units of the conditioner carry a voltage and it is life-threatening! For repair of the appliance refer to an authorized service center.
  7. Don’t use the appliance if it is faulty, or if it was dropped or damaged.
  8. Don’t open a front panel of the appliance during its work.
  9. Don’t dismantle and modify the appliance.
  10. Unplug the conditioner immediately, if it emits strange odours or smoke.
  11. Don’t splash and pour water and other liquids on the conditioner.
  12. Always unplug the conditioner during a lighting storm.
  13.  Always unplug the conditioner, when it is not used.
  14. Before cleaning and maintenance of the conditioner unplug it. Cleaning and maintenance should be performed in accordance with instructions of this manual.
  15. To ensure the effective work of the conditioner, operate it in environment described in the present manual.
  16. Don’t use dangerous chemicals for cleaning of the appliance and don’t let them on the appliance.
  17. When removing an air filter, don’t touch metal parts of the appliance.
  18. To avoid overheating and risk of flash fire, as well as damage of internal electric network, don’t change the length of a power cord and don’t connect the appliance via extension cords.
  19. To avoid electrical hazards, damaged power cord must be changed only at authorized service centers qualified professionals.
  20. To avoid risk of electric shock, do not place the power cord near a heater and flammable or combustible substances.
  21. Do not start or stop the unit by connecting or disconnecting electrical power.
  22. To avoid electric shock, a damaged power cord should be replaced only in authorized service centers by qualified specialists.
  23. To avoid electric shock, don’t place the power cord near heating appliances and flammable or combustible substances.
  24. Don’t start and stop the appliance by power-up and down.
  25. Don’t press the buttons of the remote control board by anything but your fingers.
  26. Don’t use the appliance for purposes not intended by this user manual.

APPLIANCE DESCRIPTION

The conditioner consists of indoor and outdoor units connected by pipelines. The conditioner may be controlled from a remote control board or from an indoor unit control panel.

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig1

Fig. 1

  1. Front panel
  2. Display
  3. Air Filter
  4. The air intake
  5. The horizontal grille
  6. On / Off button

DELIVERY SET

Complete set of air conditioner (split system) includes:
Conditioner unit for indoor installation -1 piece
Conditioner unit for outdoor installation -1 piece
Remote control board -1 piece
Batteries for remote control board – 1 pcs.
User manual -1 piece
Guarantee slip -1 piece
Packing of indoor-installation unit -1 piece
Packing of outdoor-installation unit -1 piece

DISPLAY INDOOR UNIT

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig2

In standby mode, the power indicator lights redmode lamp is off.
The conditioner may be controlled from a remote control board

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig3

OPERATING MODES

ON/OFF button
Press this button can turn on or turn off the air conditioner.
MODE button
Press this button to select your required operation mode.

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig4

When selecting auto mode, air conditioner will operate automatically according to exfactory setting. Set temperature can’t be adjusted and will not be displayed as well. Press «FAN» button can adjust fan speed. Press « » or « » button can adjust fan blowing angle.
After selecting cool mode, air conditioner will operate under cool mode. Press « + » or « – » button to adjust set temperature. Press «FAN» button to adjust fan speed. Press « » or « » button to adjust fan blowing angle.
When selecting dry mode, the air conditioner operates at fan1 under dry mode. Under dry mode, fan speed can’t be adjusted. Press « » or « » button to adjust fan blowing angle.
When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. Press «FAN» button to adjust fan speed. Press « » or « » button to adjust fan blowing angle. When selecting heating mode, the air conditioner operates under heat mode. Press « + » or « – » button to adjust set temperature. Press «FAN» button to adjust fan speed. Press « » or « » button to adjust fan blowing angle. (Cooling only unit won’t receive heating mode signal. If setting heat mode with remote controller, press ON/OFF button can’t start up the unit).
NOTE:
For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend on indoor ambient temperature). Set temperature range from remote controller: 16~31 0 C; Fan speed: auto, fan1, fan2 , fan3, fan4, fan5, turbo,stepless speed.
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), fan1( ), fan2 ( ), fan3 ( ), fan4( ), fan5 ( ), turbo( ),stepless speed.

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig5

NOTE:
In AUTO speed, air conditioner will select proper fan speed automatically according to ambient temperature.
Fan speed under dry mode is fan1.
After entering the infinite fan speed mode, users can adjust the fan speed according to the button « » or « ».
button
Press this button the up&down swing function can be started and canceled. The remote controller defaults to static swing condition. Press «MODE» button and « » button at the same time when remote controller OFF to switch between simple swing and static swing. In static swing condition, pressing button, the swing angle of up & down louver changes as below:Cooper Hunter Split Air
Conditioner Nordic PREMIUM Series - fig6 NOTE:
When selecting « » with remote controller, it’s auto swing. Horizontal louver of air conditioner will swing up&down automatically at the maximum angle.
When selecting « » with remote controller swing. Horizontal louver of air conditioner will stop at that position as shown by the icon to swing.There is no this function for some remote control.

button
Rotate button blinds left / right in this series do not used «Health» button -to activate the mode in this series do not used Press «MODE» button and « » button at the same time at remote controller OFF to switch between simple swing and static swing.
In static swing condition, pressing button, the swing angle of left & right louver changes as below:

Cooper Hunter Split Air Conditioner Nordic PREMIUM Series -
fig7

When selecting « » with remote controller, it’s auto swing. Vertical louver of air conditioner will swing up&down automatically at the maximum angle.
When selecting « » position swing. Vertical louver of air conditioner will stop at that position as shown by the icon to swing.

There is no this function for the units. If press this button, the main unit will sound, but it also runs under original status.
« + » and « – » button Press « + » or « – » button once to increase or decrease 1 0 C of set temperature.
Holding « + » or « – » button, set temperature on remote controller will change quickly. On reseasing button after setting is finished, temperature indicator on indoor unit will change accordingly. (Temperature can’t be adjusted under auto mode)
When setting TIMER ON, TIMER OFF or CLOCK, press «+» or «-» button to adjust time (Refer to TIMER ON, TIMER OFF buttons).
HEALTH button (Option)
Press this button to turn on or turn off the PLAZMA PATROL Filter.
NOTE:
If there is no this function for units, If press this button, the main unit will sound, but it also runs under original status.
SLEEP button Press this button to turn on or turn off the SLEEP function under cool heat dry mode.
NOTE:
This function is off as defaulted after power on.
It will be cleared after changing mode.
It is no use under «FAN» mode and «AUTO» mode.
I FEEL button
Press this button to start I FEEL function and « » will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the indoor unit and the unit will automatically adjust the indoor temperature according to the detected temperature. Press this button again to close I FEEL function and « » will disappear.
NOTE:
In hte first power on, the Clean mode is turned off acquiescent.
Please put the removte controller near and confirm the unit can receive the remote code when this function is set. Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature.
TEMP button

  1. Normally the indoor unit displays setting temperature ;

  2. Press “Tem” button for 1 time, the indoor unit will display indoor ambient temperature ;
    ① Without operation in 3s, return to display setting temperature;
    ② Press “Tem” button 2nd time in 3s, the indoor unit will display outdoor ambient temperature;

  3. press “Tem” button 3rd in 3s, the indoor unit will dispaly seeting temperature immediately.
    No operation, will display seeting temperature after 3s.

TIMER button
This button can set the time for timer on (timer off). After pressing this button, “HOUR ON (HOUR OFF)” and “ “ icon on remote controller blinks. Press “

  • “ or “ – “ button withing 5s to set timer on (timer off) time. Each pressing of “ + “ or “ – “ button, the time will increase or decrease 0.5 hour. Hold “

  • “ or “ – “ button, the time will change quickly until reaching your required time. Press “Timer” to confirm it. The word “HOUR ON (HOUR OFF)” will stop blinkink. “HOUR ON (HOUR OFF)” and “ “ on remote controller will be displayed.
    Cancel Timer on(off)
    In the condition of timer on (off) is started up, press “Timer” button to cancel it.
    NOTE:
    Time set range: 0.5-24 hours.
    When timer on has set, the controller displays as the unit is on.
    Timing of the initital set hour is 0.0 hour.
    Function introduction for combination buttons
    Child lock function
    Press “ + “ or “ – “ simultaneously to turn on or turn off child lock function.
    When child lock function is on, « » icon is displayed on remote controller.
    If you operate the remote controller, the « » icon will blink three times without sending signal to the unit.
    Wi-Fi function setting
    Press “Power” + “Mode” button for 3s, into the WIFI setting.
    For detailed information on the settings for the eHome application please use the following link: https://cooperandhunter.ua/split/files/docs/support_20190220174724506.pdf
    Temperature display switchover function

    In the off mode, press « – » and «MODE» buttons simultaneously to switch temperature display between 0 C and °F. Low temperature heating function setting In heating mode, pressing «Mode» and « + » button at the same time will enter/exit the low temperature heating function. «LA» would be showed on the remote controller after entered into the low temperature heating funtion. When switching from one mode to another mode, low temperature heating function was canceled. Turn off and then turn on air conditioner that will remain the low temperature heating function. After powered on, the low  temperature heating mode was default to off status.In the low temperature heating mode, «SLEEP» and «Low temperature heating» function cannot start at same time. When low temperature heating mode has already started,meanwhile you press the «sleep» button, the air conditioner will exit low temperature heating mode and enter the sleep mode. Vice versa.
    NOTE:

    1. In the low temperature heating mode, the fan speed was default to Auto and nonajusatable.
    2. In the low temperature heating mode, «TURBO» and «QUIET» can’t be set. If enter the low temperature heating mode,the turbo and quiet function that started before will be canceled. As well as when exit the low temperature heating mode, it will not resume.
    3. When exit from the low temperature heating mode, the speed and temperature will turn into the original condition before it started.
    4. You can set up other function.

MAINTENANCE

  • Before cleaning unplug the conditioner.
  • Cleaning of the indoor unit and remote control board:
  • Indoor unit and remote control board should be cleaned with a dry soft cloth.
  • If the indoor unit is too unclean, moisten the cloth with cold water.
  • It is prohibited to clean the remote control board with moist cloth.
  • In order to avoid the damage of paint or details of the conditioner, do not clean it with brushes and do not leave them on the surface of indoor unit.
  • In order to avoid the damage of surface or deformation of the conditioner details, do not clean it with petrol, solvents, cleaning powders or other chemically active substances.
  • Before a sustained interruption in the conditioner work:
  • Turn the conditioner on for several hours in the FAN mode. It will allow you to dry its inner cavities
  • Unplug the conditioner. Remove the batteries from the remote control board.
  • Checks before starting:
  • Make sure that an air filter is installed.
  • Make sure that air inlet and outlet grilles of the outdoor unit are not blocked by foreign objects.
  • Cleaning of air filter
  • Air filter cleans the air entering the conditioner from dust and foreign particles. If the filter is contaminated, the conditioner capacity decreases sharply.
  • If the conditioner is operated permanently, the filter should be cleaned once per two weeks.
  • If the conditioner is installed in a room with dusty atmosphere, then the air filter should be cleaned more often.
  • To remove the filter, open the indoor unit panel.
  • Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean water. If the filter is contaminated heavily, clean it with a soft brush and wash in diluted washing solution, then dry it in a cool place.
  • While cleaning the filter with the vacuum cleaner, hold it with contaminated surface up. While washing the filter in water, hold it with contaminated surface down.
  • Do not dry the filter in the sun or near a fire.
  • Set the air filter to initial position and close the panel.

TROUBLESHOOTING

In case of emergency, please, use the troubleshooting methods shown in tables. If it is impossible to solve problems with these methods, apply to the service center.
Failures and their possible reasons:

Failure Possible reason Actions
The conditioner does not work Interruptions in power supply Wait for

restoration of power supply
Batteries in the remote control board are low| Replace the batteries
Time of turning on is set by the timer| Wait till the conditooner turns on by the timer or cancel the timer setting
Insufficient cooling or heating capacity
The conditioner works, but does not cool or heat the room| The set air temperature is too high or too low| Set the air temperature correctly
The air filter is clogged with dust| Clean the air filter
Foreign objects block the air intel and return air grillages of the outdoor unit| Remove foreign objects
A three-minute delay of compressor tuming on| Wait a little
The air temperature is set incorrectly| Set the temperature correctly

TRANSPORTATIOM AND STORAGE

Temperature requirements* Transportation and storage From -30° to +50°
Humidity requirements* From 15% to 85% (without a condensate)

We are exploring new technologies and we constantly improving the quality of our products. That’s why specifications, design and accessories are subject to change without any specific notice.

  • This product must have storage in dry, well-ventilated space of warehouse at the temperature not lower than -30°C.

SERVICE LIFE

Service life of the appliance is 10 years provided that the respective installation and operation rules are observed.
Date of the conditioner manufacture is shown in a serial number of the device. For more details, please, ask a shop assistant.

UTILIZATION RULES

Upon expiration of the service life, the appliance should be utilized in accordance with norms, regulations and procedures effective in the place of utilization.

WORKING TEMPERATURE RANGE

| Indoor side DB/WB( C )| Outdoor side DB/WB(`C )
---|---|---
Maximum cooling| 32/23| 52/32
Maximum heating| 27/-| -28/18

NOTICE:

  • The operating temperature range (outdoor temperature) for cooling is 18 ℃ ~ 52 ℃ ; for heating is -28 ℃ ~ 24 ℃ .

Cooper Hunter - logo Designed by Cooper &Hunter International Corporation, Miami, FL, USA
‘ Cooper & Hunter is constantly working to improve their products,
so the information in this manual is subject to change without prior notice.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Cooper Hunter User Manuals

Related Manuals