LITECRAFT BeamX.7 LED Par Black User Manual

June 15, 2024
LiTECRAFT

LITECRAFT BeamX.7 LED Par Black

LITECRAFT-BeamX-7-LED-Par-Black-PRODUCT

Product Information

This product is a LITECRAFT device designed for lighting purposes. It is developed and manufactured with high-quality standards to ensure optimal performance and user safety. The latest version of the user manual can be obtained by scanning the QR code on the cover of the manual.

Product Usage Instructions

  • MONTAGE (Installation)
    • When mounting, disassembling, or performing maintenance on the spotlight, make sure to secure the area below the installation site. Use an appropriate safety rope for this purpose.
  • ELEKTRISCHER ANSCHLUSS (Electrical Connection)
    • The protective conductor must be properly connected throughout the entire installation.
  • REINIGUNG UND WARTUNG (Cleaning and Maintenance)
    • Follow the provided cleaning and maintenance instructions to ensure the longevity and optimal performance of the product.
  • BEDIENUNG (Operation)
    • The display on the device provides information about various DMX modes, DMX start address, program, program speed, etc.
    • The first line of the display shows the mode, and the second line shows the corresponding value.
  • WIRELESS DMX-BETRIEB (Wireless DMX Mode)
    • Instructions for operating the device in wireless DMX mode can be found in the user manual.
  • DISPLAY-MODUS (Display Mode)
    • Instructions for using the device in display mode can be found in the user manual.
  • DMX-MODUS (DMX Mode)
    • Instructions for using the device in DMX mode can be found in the user manual.
  • PHOTOMETRISCHE DATEN (Beam Specs)
    • The photometric data of the device can be found in the user manual.
  • TECHNISCHE SPEZIFIKATIONEN (Technical Specifications)
    • Detailed technical specifications of the product can be found in the user manual.
  • CE-CERTIFICATION (CE Certification)
    • Information about CE certification for the product can be found in the user manual.

ACCESSORIES INCLUDED

  • powerCON mains cable
  • IR remote
  • frost filter 25°
  • 4x fixing screws for frost filter 25°

SAFETY NOTES

Each person being responsible for the installation, use or service of this unit must:

  • be qualified
  • follow the instructions in this manual.

WARNING! Be careful when using the device. You risk an electrical shock from high voltage, if you touch the wires!

  • The device has left our company in manufacturer proofed state. To maintain this status and to ensure a permanent safe operation, it is absolutely necessary to follow the safety instructions and warnings in this manual.

IMPORTANT!
Errors, caused by not following these instructions are not covered by the warranty. The manufacturer will not accept liability for any resulting defects or problems.

  • Keep the unit away from radiators or other heat sources!
  • If the unit has been exposed to tremendous temperature changes (e.g. after transportation), do not turn it on immediately. The resulting condensation could damage the unit. Don’t switch the unit on until the device reaches room temperature.
  • This device belongs to protection class I. Therefore, it is imperative that the green/yellow wire is connected to the earth contact of the plug. The electrical connection must be made by a qualified person.
  • Make sure that the cable has never been squeezed or damaged by sharp objects. Check the device and the cables regularly.
  • If the cable is damaged, it must be replaced immediately by the manufacturer, its service agent, or a qualified person in order to avoid danger.
  • Lenses, glasses or UV filters must be replaced if they are visually damaged, or their effectiveness is impaired, e.g. by broken glass or by deep scratches.
  • Ensure that wires never come in contact with other wires! Handle the power cord and all connections with caution!
  • Make sure that the line voltage is not higher than the voltage specified in this manual.
  • Disconnect the unit from the AC mains when it is not in use or when cleaning it. Disconnect the connection only by pulling the cable plug.
  • Using the fixture for the first time can result in light smoke and odors. This is a normal process and does not constitute a defect.
  • This device is not intended for use in tropical climate zones!

RISK OF BURNS!

  • Do not touch the unit during operation! The housing may reach high temperatures.

RISK TO HEALTH!

  • Never look directly into the light source. Especially epileptics risk an epileptic shock! Disconnect the unit from the AC mains when not in use or when cleaning it.
  • Defects can be used by modifications of the device by unqualified handling or an unqualified person is not covered by warranty.
  • Keep the product away from children and unskilled people.
  • There are no worn parts in the device. Maintenance and service may only be carried out by authorized service partners.

DESIGNATED USE

This product is a spotlight, which is designed only for professional use on stages, discotheques, theatres, etc. This product is approved for mains connection up to 2 6 0 VAC and designed for indoor use, but not for permanent indoor installation. The protection class is classified as IP 2 0

  • Please avoid any kind of shocks and damage during its installation or transportation.
  • Take care of too-high ambient temperatures, humidity, and dust when choosing the installation location. Assure that all cables are fixed. Incorrect operation may lead to danger.
  • The image shows the minimum distance to illuminated objects. The minimum distance between the fixture and the illuminated surface is 0,1 meters
  • Assure that the area below the mounting position of the fixture is closed off while mounting, dismantling, and servicing.
  • The spotlight itself and its accessories like color frame and barn doors have to be secured with a suitable safety chain.
  • Assure that the maximum ambient temperature is never exceeded.
  • Do not put the fixture in operation before you are familiar with its functions. Keep the product away from children and unskilled people.
  • The long service life that is specified for the LEDs used refers exclusively to the LEDs, not to all other electronic and mechanical components that are subject to a different aging process, depending on use and permanent operation with mains voltage.

INSTALLATION

There are specific regulations like DGUV V17/18 (old BGV C1) or country- related regulations that need to be respected during the installation. Only skilled persons may install the device.

  • A suspension device has to be built and calculated in order to handle up to 10 times its specific load limit over a time of one hour without permanent or harmful deformation.
  • The installation has to be done with a separate, independent suspension device like a safety chain. A second suspension device has to be built in order to ensure that in case of error, no part of an installation can fall off.
  • Trespassing in the danger zone below the installation during the assembly is prohibited.
  • The installer has to make sure all safety and machinery installations are approved by authorized persons before the first operation or after changes before restarting.
  • The installer has to make sure that all safety and machinery installations are approved by skilled persons at least once a year.
  • The installer has to take care of all safety and machinery installations being approved by authorized persons at least every four years during the acceptance inspection.
  • The spotlight should ideally be installed outside people’s lounge area.

ATTENTION!
Installation overhead needs a high level of experience. This includes (but is not just limited to) calculation and definition of load c apacity, used installation material and regular safety inspections of used material and the fixture itself. Never try to do the installation by yourself if you are not qualified. Turn to a skilled installer instead. Inappropriate installations can cause in juries and/or damage of property.

  • The s potlight has to be installed outside areas where people can touch it.
  • A professional truss system or similar licensed suspension systems have to be used if the spotlight is used in suspension from ceiling or other co nstructions. Spotlights can never be installed freely suspended!

ATTENTION!

  • Spotlights can cause injuries when falling off. If you are not trained in questions of safety for the different kinds of installations DO NOT install the spotlight!
  • Assure that t he mounting surface can carry at least ten times the point load of the spotlight before installing the fixture.

ATTENTION!

  • Assure the specified safety distances to flammable materials.
  • Attach the spotlight with its yoke and the use of a suitable hook/cla mp to your truss system. According to your installation also similar but approved suspension devices are possible. The therefore used opening has a diameter of about 10 mm.
  • When installing the spotlight overhead, make sure to secure the fixture with a safety chain which is specified at least with a load limit of 12 times of the spotlight’s weight.
  • Only safety chains with approved connections can be used. Attach the safety chain to its designated opening and attach it to the truss system or a similar and saf e attachment point. Assure to close the fasteners as specified.
  • To adjust the angle of the fixture, open the locking screw, set the fixture in its position, and close it by hand again.

ELECTRICAL CONNECTION

Connection to the mains is only allowed by skilled persons.

  • Before connecting the fixture to the mains, ensure that the specifications are corresponding.
  • Electrical grounding has to be used in the whole installation!

ATTENTION!

  • Installation has to be approved by an authorized person before the first operation!

CLEANING AND MAINTENANCE

  • The installer has to make sure all safety and machinery installations are approved by skilled persons at least once a year.
  • The installer has to make sure all safety and machinery installations are approved by authorized persons at least every four years during the acceptance inspection. The following points require special attention:
    • All screws used for mounting the fixture or parts of need to be locked and must not show corrosion. Housing, suspension device and installation site (ceiling, suspension, truss) must not show deformation.
    • All power cords must not show any damage, aging (for example porous wires) or sediments. Other, to location-related and usage-aligned regulations will be observed by the skilled person and safety defects will be fixed.

ATTENTION!

  • Make sure that the fixture is disconnected from the mains during all maintenance!

Is it important to unplug the mains connector?

  • The fixture must be regularly cleaned of dirt and dust. Only use a wetted, lint-free cloth for cleaning the fixture. Never use alcohol or any kind of solvent for cleaning.
  • Inside the fixture, there are no parts that need maintenance. Maintenance and service must be done by authorized dealers only. Only use original spare parts!

Advice!

  • If you have further questions, your local dealer will be happy to help you.

OPERATION

This device has several DMX and stand-alone modes. In DMX mode, multiple devices can be connected and controlled by a controller. The device accepts the settings of the DMX controller, as soon as the corresponding start address is set.

  • Slave mode:
    • Connect the DMX output of the master device (XLR female) to the DMX input of the slave device (XLR male). Set the slave device to mode slave (display shows: ). The slave device accepts all settings of the master device (such as program, program speed, and color).
  • Display description:
    • The display shows the different DMX modes and the DMX start address or program, program speed, etc. The first line shows the mode, and the second line the corresponding value.
  • Button Description:
    • Press the MENU button to get access to the menu.
    • Press the UP/DOWN button to select the relevant topic. Press the ENTER button to change the relevant topic.
    • Change the relevant topic by pressing the UP/DOWN button to set the DMX start address or any of the pre-programmed modes or speed values.
    • Use the UP button to increase the value. Use the DOWN button to decrease it. Press the ENTER button again to save your settings and get access to the next menu.

NOTE!
If you hold the UP or DOWN button for longer, the value changes faster. The device has automatic storage for all settings. When you turn the device off and on again, it works with the previously set values. If the unit is not operated for about 30 seconds, the buttons are locked. Unlock these by pushing one of the backside buttons for about three seconds.

  • The unit is additionally equipped with an infrared remote control. The use of this infrared remote control is possible in every mode. Point the infrared remote control in direction of the infrared receiver on top of the fixture. Choose a color or a program by using the infrared remote control.
  • To leave infrared mode press the button “OFF” on the remote control, press one of the backside buttons on the fixture, or switch off the unit and on again by removing the mains plug from the mains.

OVERVIEW

LITECRAFT-BeamX-7-LED-Par-Black-FIG-1
\(3\)

  • A. Yoke
  • B. IR Sensor
  • C. Locking Screw
  • D. CRMX Input
  • E. DMX Input 5-pin
  • F. LC-Display
  • G. DMX Output 5-pin
  • H. Menu Button
  • I. Mains Input
  • J. U p Butt on
  • K. Down Button
  • L. Mains Output
  • M. Enter Button
  • N. Safety Attachment Point

WIRELESS DMX-MODE

  • The unit is equipped with a connector for an optional LUMENRADIO CRMX Wireless DMX module. The module is compatible to CRMX transmitter units from LUMENRADIO and WIRELESS SOLUTIONS transmitter units version G3 and G4.
  • For use with CRMX the LUMENRADIO CRMX Wireless DMX module needs to be plugged into the backside USB connector and the unit must be set to one of the five DMX modes.
  • Press the MODE button and use the UP/DOWN buttons until the display shows „DMX Chan“.
  • Press ENTER and choose the right mode by using of UP/DOWN buttons.
  • Furthermore, you need to choose the corresponding DMX-start address.
  • Which mode is the right one for you is up to the range of functions you would like to use, the library, and the channels of the used DMX controller.
  • Please read chapter DMX-mode of this manual to get an idea of which channels can be controlled in which DMX-mode.
  • Up next there is a need for a logical connection (pairing) of the unit with an external DMX transmitter.
  • Press the CONNECT button on the DMX transmitter shortly. The transmitter searches for all available units and connects to them. The logical connection (pairing) is done and saved until it is released manually.

NOTE!

  • If a unit is not connecting to an external DMX transmitter it is already connected logically to another transmitter.
  • In this case, the connection needs to be released manually.
  • Press and hold the CONNECT button on the LUMENRADIO CRMX Wireless DMX-Module for at least 3 seconds.
  • After this please repeat the procedure for logical connection (pairing) whilst pressing the CONNECT button on DMX-transmitter shortly again.

DISPLAY MODE

Display function
DEF. SET DEF. SET

<***>

*** =

| reset all parameters to factory defaults
DMX Addr| DMX Addr| display the DMX-address
 | <>| (2 Ch = <001-511>)
 |
= DMX-adress| (3 Ch = <001-510>)
 |  | (4 Ch = <001-509>)
 |  | (5 Ch = <001-508>)
 |  | (10 Ch = <001-503>)
 |  | (default setting = 1)
DMX Chan| DMXChan| setting DMX-channel mode (description of modes in next chart) (default setting = 4 Ch)
 | =
 |
=
 | < 2Ch>
 | < 3Ch>
 | < 4Ch>
 | < 5Ch>
 | <10Ch>
Dimmer| Dimmer| setting dimmer curve
 | <>| OFF = dimmer linear
 |
=| 1 = dimmer delayed 1
 | | 2 = dimmer delayed 2
 | <1>| 3 = dimmer delayed 3
 | <2>| 4 = dimmer delayed 4
 | <3>|
 | <4>|
Master/Slave| Master/Slave

<**>

** = Master

** = Slave

| setting working mode

(Master = control without external controller)

(Slave = control with external controller)

(default setting = Slave)

ColSet| ColSet| setting brightness for each color in
 | | steps of 256
 | <>|
 |
= <0-255>|
 | |
 | <>|
 |
= <0-255>|
 | |
 | <>|
 |
= <0-255>|
 | |
 | <>|
 |
= <0-255>|
ColMac| ColMac

<**>

** =

<00-43>

| 43 pre-programmed colors combinations available

(deactivation of all pre-programmed chasers by menu Master/Slave!)

---|---|---
ColProgr| ColProgr

<**>

** =

<00-31>

| 31 pre-programmed chasers available (deactivation of all pre-programmed chasers by menu Master/Slave!)
Speed

<**>

** =

<00-30>

| setting speed in 30 steps for the pre- programmed chaser available
WhiteBal| WhiteBal| setting white balance
 | | (default setting =
 | <>| R = 255, G = 255, B = 255)
 |
= 125-255|
 | |
 | <>|
 |
= 125-255|
 | |
 | <>|
 |
= 125-255|
Temp.| Temp

<***C>

<***C = operating temperature

| Display the current temperature inside the fixture
DispPerm| <DispPerm ***>

*** = ON

*** = OFF

| setting automatic switch off for lcd backlite

(default setting = On)

DMX MODE

Mode display function
2 channel mode < 2 Ch> ch1 = color macro

000-255 stepless rgb color mix ch2 = master dimmer

000-255 stepless brightness

3 channel mode| < 3 Ch>| ch1 = dimmer red

000-255 stepless brightness red ch2 = dimmer green

000-255 stepless brightness green ch3 = dimmer blue

000-255 stepless brightness blue

4 channel mode| <4 Ch>| ch1 = dimmer red

000-255 stepless brightness red ch2 = dimmer green

000-255 stepless brightness green ch3 = dimmer blue

000-255 stepless brightness blue ch4 = dimmer white

000-255 stepless brightness white

5 channel mode| <5 Ch>| ch1 = dimmer red

000-255 stepless brightness red ch2 = dimmer green

000-255 stepless brightness green ch3 = dimmer blue

000-255 stepless brightness blue ch4 = dimmer white

000-255 stepless brightness white ch5 = master dimmer

000-255 stepless brightness

10 channel mode| <10 Ch>| ch1 = dimmer red

000-255 stepless brightness red ch2 = dimmer green

000-255 stepless brightness green ch3 = dimmer blue

000-255 stepless brightness blue ch4 = dimmer white

000-255 stepless brightness white ch5 = color macro

000-255 stepless rgb color mix ch6 = flash rate

000-020 no function

021-255 flash rate from s -> f ch7 = programms

000-020 no function

021-099 color jumps

100-149 color fades

150-255 no function ch8 = speed

000-255 stepless speed

 |  | ch9 = dimmer mode

000-020 mode set on display 021-049 off = dimmer linear 050-099 1 = dimmer delayed 1

100-149 2 = dimmer delayed 2

150-199 3 = dimmer delayed 3

200-255 4 = dimmer delayed 4 ch10= master dimmer

000-255 stepless brightness

---|---|---

BEAM SPECS

  1 m 3 m 5 m
red 4.690 lx 670 lx 230 lx
green 11.050 lx 1.860 lx 273 lx
blue 450 lx 70 lx 22 lx
white 10.190 lx 1.450 lx 518 lx
RGB 24.580 lx 3.710 lx 1.374 lx

TECHNICAL SPECIFICATION

optical system|
---|---
optics| fixed optical system
beam angle| 10° (frost filter 25° inclusive)
LED-sources|
LEDs| 7x multichip LEDs
colors| 7x red, 7x green, 7x blue, 7x white
life time LEDs| > 50.000 hours
color mixing| RGBW
temperature range|
ambient temperature| 0°/+45° C
cooling| convection cooling
control & programming|
protocol| DMX 512, IR-remote

(LUMENRADIO CRMX optional)

DMX 512-channels| 2/3/4/5/10 (5 modes)
internal memories| stand alone-programms, macros
 | fixed colors, master-/slave-control
menu-display| LC-Display
DMX 512-connection| XLR 5 pin

(XLR 3 pin as option)

technical data|
mains voltage| 100-260 V 47-63 Hz
power consumption| 0,2 A @ 230 V
housing|
material| aluminium
color| black
ip-rating| IP 20
size/weight|
size (l x w x h)| 24,1 x 15 x 21,6 cm
weight| 2,5 kg
mounting| compact y-yoke for hanging
 | and standing mount

CE-CERTIFICATION

LITECRAFT-BeamX-7-LED-Par-Black-FIG-1
\(4\)

latest online version

  • contact details
  • LMP Lichttechnik Vertriebs GmbH
  • Gildestraße 55
  • D-49477 Ibbenbüren
  • +49 5451 5900-800
  • sales@lmp.de.
  • ©2022, LMP Lichttechnik Vertriebs GmbH All rights reserved subject to change without notice

Thank you for purchasing this LITECRAFT product This device was developed and manufactured under high quality requirements. For your own safety and to ensure optimal use of your new product, please read these operating instructions carefully before using it for the first time. You can obtain the latest version of this user manual by scanning the QR code on the cover of this user manual.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals