BLUE SEAL Sapiens E6BSD Electric Combi Oven Steamer Owner’s Manual

June 13, 2024
BLUE SEAL

BLUE SEAL Sapiens E6BSD Electric Combi Oven Steamer

Features

  • Direct steam injection system

  • Manual controls

  • Electronic thermostat 30°C-300°C

  •  AUTOCLIMA automatic system for controlling the perfect climate in the cooking chamber

  • Variable fan speed with up to 6 speeds

  • 3.5” LCD – TFT colour display for favourite programs, pre-set programs, fan, automatic washing, menus and settings

  • LED HVS alphanumeric display for temperature,
    Autoclima, time and core temperature

  • Rapid selection scroller knob for program using scroll & push functions

  • Multi-point core temperature probe

  • Built-in retractable hand shower with tap

  • USB connection to download HACCP data, software updates and storing cooking programs

GENERAL FEATURES

Cooking modes
  • 95 preset recipe programs, including programs for reheating on the plate / pan
  • 99 free programs, up to 9 cycles with name and icon creation
  • Fast-Dry Boosted® – automatic system for quick dehumidification of the cooking chamber
Operation
  • LED bars to indication actual cooking cycles in program mode
  • Manual pre-heating
  • Auto reverse (automatic reversing fan rotation) for perfect cooking uniformity
  • Automatically regulated steam condensation
  • Manual chamber pressure relief control
  • Manual humidifier
  • ECOVAPOR – automatic control of the system saturation in the cooking chamber
  • Intelligent Energy System- oven optimises and controls the delivery of energy output to maintain best cooking temperature
  • Self-diagnosis and fault display
Construction
  • Perfectly smooth, watertight chamber
  • Rear ventilated double tempered glass door with air chamber and interior heat-reflecting glass for less heat radiation towards operator
  • Hinged inner glass for easy cleaning
  • Adjustable door hinge for optimal seal
  • Low consumption LED cooking chamber light
  • IPX5 spray-proof and hose proof
  • East Maintenance Access (EMA) – easy access for service maintenance at bottom front and right hand side of machine
Cleaning
  • Vapour Cleaning System (VCS) automatic washing system caters for cleaning with reduce detergent usage in the chamber
  • 7 automatic wash programs – manual, rinse, fast, soft, medium eco, hard eco, grill
  • Wash Management System (WMS) – preschedule washing programs based on combi use
OPTIONAL FEATURES
  • Right hinged door
  • Configuration for connection to extraction hood

Dimensions

Width 852mm
Depth 797mm
Height 775mm
Weight 110kg

Packed dimensions

Width 990mm
Depth 940mm
Height 980mm
Weight 134.1kg

Shelves

1/1 GN 6
Shelf Spacings 70mm

Installation requirements

(for precise installation instructions, please refer to the unit’s installation manual).

Power connection requirements

Multi pole circuit breaker and all pole disconnection isolator switch installed near the appliance.

Supply line voltage

400-415V ~ 50Hz, 3P+N+E Special voltage options available on request.

Power connection

Total (kW) 11.6
Convection power (kW) 11
Rated Current (A) (400V) 18

Installation clearances

  • Rear 50mm
  • Right   500mm
    Left   50mm

*Clearance required on fixed installations for service accessibility

If heat sources are located near the RH side of the Sapiens combi, ensure that a minimum distance of 400mm is maintained.
Install in accordance with local body regulations only on horizontal surfaces and not against combustible walls.

Water connection requirements\

  •  Cold water
  • Flow pressure (200-500kPa)
  • Min. Water Flow 10 l/min
  • Soft water connection*
  • Shut-off valve with return flow inhibitor and dirt filter
  • Water supply R3/4
  • R50 waste water connection

Water quality
Total Water hardness 60-90ppm
pH >7.5
Cl (chloride) max. 30 mg/l
Cl2 (free chlorine) max. 0.1 mg/l
Fe (Iron) max. 0.1 mg/l
NH2Cl (monochloramine) 0.2 mg/l
Cold water temperature max. 30°C
Soften water temperature max. 50°C
Electrical conductivity 50 – 200 μS/cm

(*Water treatment may be required. Please refer to installation manual.)

Emissions

Latent heat 2088W
Sensible heat 1392W
Waste water max
discharge temperature 100°C
Noise during operation <50 dBA

CUSTOMER SUPPORT

Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz

Australia
Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road
Mulgrave, Victoria 3170
Telephone 03-9518 3888
Facsimile 03-9518 3833
vsales@moffat.com.au

New South Wales
Telephone 02-8833 4111
nswsales@moffat.com.au

South Australia
Telephone 03-9518 3888
vsales@moffat.com.au

Queensland
Telephone 07-3630 8600
qldsales@moffat.com.au

Western Australia
Telephone 08-9413 2400
wasales@moffat.com.au

New Zealand
Moffat Limited

Rolleston
45 Illinois Drive
Izone Business Hub
Rolleston 7675
Telephone 03-983 6600
Facsimile 03-983 6660
sales@moffat.co.nz

Auckland
Telephone 09-574 3150
sales@moffat.co.nz

In line with policy to continually develop and improve its products, Moffat Limited reserves the right to change specifications and design without notice.

References