Altronix T1VK34V Trove Access and Power Integration Installation Guide
- June 13, 2024
- Altronix
Table of Contents
**Altronix T1VK34V Trove Access and Power Integration Installation Guide
**
Models Include
T1VK34V
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TV1 Altronix/HID VertX® backplane
- One (1) AL600XB220 – Power Supply/Charger
- One (1) VR6 – Voltage Regulator
- One (1) PDS8 – Dual Input Fused Power Distribution Module
T2VK78V
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TV2 Altronix/HID VertX® backplane
- One (1) AL1024XB2V – Power Supply/Charger
- One (1) ACM8 – Fused Access Power Controller
- One (1) VR6 – Voltage Regulator
- One (1) PDS8 – Dual Input Fused Power Distribution Module
T3VK7520V
20 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with TV3 Altronix/HID VertX® backplane
- One (1) AL1024XB2V – Power Supply/Charger
- One (1) AL1012XB220 – Power Supply/Charger
- Two (2) ACM8 – Fused Access Power Controllers
- One (1) ACM4 – Fused Access Power Controller
- One (1) PD8UL – Fused Power Distribution Module
- One (1) RSB2 – Rocker Switch Bracket with Two (2) Switches
T1VK34DV
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TV1 Altronix/HID VertX® backplane
- One (1) AL600XB220 – Power Supply/Charger
- One (1) VR6 – Voltage Regulator
- One (1) PDS8CB – Dual Input PTC Power Distribution Module
T2VK78DV
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TV2 Altronix/HID VertX® backplane
- One (1) AL1024XB2V – Power Supply/Charger
- One (1) ACM8CB – PTC Access Power Controller
- One (1) VR6 – Voltage Regulator
- One (1) PDS8CB – Dual Input PTC Power Distribution Module
T3VK7520DV
20 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove3 enclosure with TV3 Altronix/HID VertX® backplane
- One (1) AL1024XB2V – Power Supply/Charger
- One (1) AL1012XB220 – Power Supply/Charger
- Two (2) ACM8CB – PTC Access Power Controllers
- One (1) ACM4CB – PTC Access Power Controller
- One (1) PD8ULCB – PTC Power Distribution Module
- One (1) RSB2 – Rocker Switch Bracket with Two (2) Switches
Overview
Altronix Trove HID VertX® kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and subassemblies. All kits accommodate a variety of HID VertX® modules for up to four (T1VK34), eight (T2VK78) or twenty (T3VK7520) doors in a single enclosure.
Configuration Chart
Altronix Model Number
| 220VAC 50/60HzInput Current (A)| Power Supply Board Input Fuse
Rating| Power Supply Board Battery Fuse Rating| Maximum
SupplyCurrent for Main Output on Power Supply board and ACM4(CB/ACM8(CB)
AccessPower Controllers’ outputs| Nominal DC Output Voltage Range
(VDC)| Fail-Safe/Fail-Secure or Dry Form “C” Outputs| Additional
Fused (PTC) Outputs| ACM4(CB)/ACM8(CB)Board Input Fuse Rating| ACM8
Board Output Fuse Rating| ACM8CB Board Output PTC Rating| ACM4 Board
Output Fuse Rating| ACM4CB Board Output PTC Rating| PDS8
BoardInput Fuse Rating| PDS8 BoardOutput Fuse Rating| PDS8CB
Board Input PTC Rating| PDS8CB Board Output PTC Rating| PD8UL
Board Output Fuse Rating| PD8ULCB Board Output PTC Rating
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
T1VK34V| **** 1.5| **** 5A/250V| ****
–| **** 24VDC @ 5.7A| 20.17-26.4| **** –| **** 8|
**** –| **** –| **** –| **** –| **** –| 10A/32V|
3A/32V| –| –| –| –
T1VK34DV| –| –| 9A| 2.5A| –| –
T2VK78V| **** 2.5| 15A/32V| **** 24VDC @ 9.7A|
20.17-26.4| **** 8| **** 8| 10A/250V| 3.5A/250V| –| ****
–| **** –| 10A/32V| 3A/32V| –| –| –| –
T2VK78DV| –| 2.5A| –| –| 9A| 2.5A| –| –
**** T3VK7520V| **** 4.1| **** 15A/32V| 24VDC @
9.1A| 20.17-26.4| **** 20| **** 8| ****
10A/250V| 3.5A/250V| **** –| 3A/32V| **** –|
**** –| **** –| **** –|
**** –| 3.5A/250V| **** –
12VDC @ 10A| 9.7-13.2
**** T3VK7520DV| 24VDC @ 9.1A| 20.17-26.4| **** –| **** 2.5A| |
**** 2.5A| **** –| **** 2.5A
Installation Instructions for Trove1, Trove2, Trove3
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
-
Remove backplane from enclosure. Do not discard hardware.
-
Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and install the two/three fasteners. Place the enclosure’s upper keyholes over the upper screws. Install the two/three lower screws and make sure to tighten all screws.
-
Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
-
Mount HID VertX® modules to back plane(s), refer to pages 3, 4, 5.
-
Refer to the XBV Power Supply/Charger Installation Guide for AL600XB220, AL1012XB220, AL1024XB2V and corresponding Sub-Assembly Installation Guides for ACM4(CB), ACM8(CB), PDS8(CB), VR6 and PD8UL(CB) for further installation instructions.
Hardware
-
Nylon Spacer
-
7/8” Pan Head Screw
-
Lock Nut
T1VK34(D)V: Installation Instructions for HID VertX® Access Controllers
-
Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 2, pg. 3).
-
Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 2a, pg. 3).
-
Fasten backplane to Trove1 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly | Pem Mounting |
---|---|
V100, V200, V300, V1000, V2000 |
-
Fasten spacers (provided) onto metal pems configuration (A) of back plane (Fig. 3, pg. 4).
-
Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 3a, pg. 4).
-
Fasten backplane to Trove2 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly | Pem Mounting |
---|---|
V100, V200, V300, V1000, V2000 |
-
Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 4, pg. 5).
-
Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 4a, pg. 5).
-
Fasten backplane to Trove3 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly | Pem Mounting |
---|---|
V100, V200, V300, V1000, V2000 |
T1VK34V and T1VK34DV (Trove1) Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
27.25” x 21.75” x 6.5” (692.15mm x 546.1mm x 165.1mm)
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056 web site:
www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty IITrove HID VertX XBV Kits
– 8 – Trove HID VertX XBV Kits Installation Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>