theleeco 855 LC2 Series Press In Check Valve Installation Guide
- June 13, 2024
- theleeco
Table of Contents
Installation Procedure IP 855 LC2 Press-In R
855 LC2 Series Press In Check Valve
REVISION HISTORY
Revision | Date | Change |
---|---|---|
A | 7/11/2017 | Initial Release |
B | 7/15/2022 | Formatting and naming |
Installation Procedure, Lee Check Valve, 855 LC2 Series, Press-In for Reverse
Flow
FACTORY INSTALLATION PROCEDURE
Overview
This procedure is intended to provide process guidelines for proper
installation of Lee Check Valve, 855 LC2 Series, Press-In product in reverse
flow orientation. Section 2 provides an overview of the installation hole
requirements. Section 3 contains the installation procedure and customer
assembly process recommendations. Section 4 contains reference information on
the installation hole and installation tool.
Compliance with this installation procedure will ensure optimal product
performance. Please contact your local Lee Company Sales Representative for
questions concerning installation of Lee Company products.
Installation Hole Requirements
The Lee Check Valve, 855 LC2 Series, Press-In product is purposely designed
for installation into plastic manifolds or fittings and to perform well under
adverse conditions. Therefore, the installation hole specifications outlined
in this section should be followed
precisely to ensure proper function of the product’s retention and sealing
features. Installation hole specifications as found on Lee Installation Hole
Drawing 1INST065550S (Appendix A) will ensure proper operation of the Lee
Check Valve, 855 LC2 Series, Press-In product. The hole should be clean, dry,
and free of burrs/flash. The series of smoothly curved lands of the Lee Check
Valve, 855 LC2 Series, Press-In product allow the valve to be pressed in while
the plastic flows into the adjacent grooves. Some plastics with a lot of
elongation, such as Polypropylene, Nylon, Acetal, Polyethylene and PEEK, cold
flow into the grooves affecting retention and sealing.
Other plastics, such as acrylic and polycarbonate, are rigid and therefore the
material must be heat flowed around the component. For installation into these
types of plastics contact your local Lee Company Sales Representative for more
information.
Installation
Installation Overview for Reverse Flow Installation
- For reverse flow applications, the Lee Check Valve, 855 LC2 Series, Press-In product is inserted into the installation hole oriented as shown.
- The installation tool (P/N: CCRT0065726S) is used to simply press the valve into a plastic installation hole until the valve is at a minimum flush with the top of the installation hole.
- The series of smoothly curved lands of the Lee Check Valve, 855 LC2 Series, Press-In product seals and retains the product in the plastic installation hole.
- Insertion should be done using Lee Installation Tool P/N: CCRT0065726S (see Appendix B). The tool and installation hole should be concentric within 0.03 mm.
Factory Best Practices:
- Examine the condition of the Installation Tool at appropriate intervals and replace if damaged or chipped.
- Clean feed bowls once per day.
- Turn off vibratory feed bowl when the assembly station is idle, or if the feed rail is full of parts.
- Use the minimum vibration setting to advance valves in the feed bowl.
- If the check valve is blown into the assembly area from the feed rail, minimize the air pressure at which the check valve is blown into the assembly area to prevent possible damage.
Appendices
Appendix A Installation Hole
DIMENSIONS IN MILLIMETERS.
Note: Draft angle to fall within diameter tolerance.
Refer to Lee Drawing No. 1INST065550S.
Appendix B Installation Tool
DIMENSIONS IN INCHES.
Marked with part number and revision.
Refer to Lee Part No. CCRT0065726S.
The Lee Company
2 Pettipaug Road
Westbrook, CT 06498-0424 USA
860-399-6281
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>