ZORRO ALERT JT-ZL2010-V Household Combustible Gas Detector User Manual
- June 13, 2024
- ZORRO ALERT
Table of Contents
ZORRO ALERT JT-ZL2010-V Household Combustible Gas Detector
Thanks
Thanks for choosing JT-ZL2010-V household combustible gas detector.
In order to ensure your personal and system safety and realize the best
product performance, please read this manual carefully and completely before
installing, using or repairing this device, and the Warnings and Notes in this
manual should be paid special attention to.
Warnings:
- Please read this User Manual carefully before using this device!
- Please keep the circuit open before installing and connecting wires to prevent electric shock!
- Non-professionals should not connect electric wires!
Product Description
The JT-ZL2010-V household combustible gas detector (detector) adopts high
quality gas sensor. It is made with high performance MCU and advanced
electronic elements as well as sophisticated technologies. Its software and
hardware technology enables it to simultaneously monitor sensor failure while
detecting gas leakage concentration, with high safety and reliability.
This detector is suitable for installing in residential houses with potential
gas leakage, it can consecutively monitor indoor combustible gas
concentration, when the gas concentrat reaches its alarming value, the
solenoid valve is automatically controlled to cut off the gas source and the
detector will send out sound and light alarm. It will help you to take
immediate action to prevent fire, blast and injury accidents from happening.
Standard implemented: EN 50194-1:2009
Technical Parameters
Model | JT-ZL2010-V |
---|---|
Operating Voltage | AC 100V~240V / 50Hz~60Hz |
Operating Environment | Tempt.: 0℃~55℃ Relative Humidity: 95%~(non |
condensation) Ambient Pressure: 86kPa 106kPa
Storage Temperature| -25℃~55℃
Sampling Method| Free diffusion
Applicable for| Methane (CH4)
Sensor Type| Semi-conductor
Sensor Life| 5 years (typical value)
Alarming Value| 7%LEL ± 3%LEL
Alarming Output| A set of 12V active pulse output for controlling the solenoid
valve
Alarming Mode| Sound + light
Alarming Sound Level| ≥85dB (1 meter ahead)
Installation| Wall-mounted
Size (LWH)| 112mm86mm33.5mm
Standard| EN 50194-1:2009
Structure and Function Indication
- Status indicator
- Service life indication
- Button
- Sound alarm holes
- Gas detection holes
- Power supply cable
- Solenoid valve cable
- Mounting baseplate
Installation Instruction
This detector is only suitable for indoor environment. Please install it where there is potential gas leakage or accumulation. and it should be installed horizontally 1m~4m from the gas appliance and vertically >0.3m from the ceiling. Users could choose install the detector according to below diagram based on actual situation.
Avoid areas as below
- Areas of ventilation inlet/outlet, exhaust fan, doors/windows with strong air flow.
- Areas with moisture and water drops.
- Areas right above heat source or water steam.
- Areas above gas appliances.
- Areas easy to be polluted.
- Areas covered by obstacles.
If the room is to be painted or refurbished, please install the detector after the refurbishment or painting work
Installation Method
- Choose a place on the wall suitable for installing the detector.
- Use expansion screws to fix the installation baseplate.
- Power on the detector and check to ensure it works normally.
- Install the detector by hanging it onto the baseplate.
Wiring Diagram
Notes :
- The power supply cable is with a plug, please directly connect to a correct socket.
- The solenoid valve has polarity, and the red positive and black negative lines must be connected one by one when connecting.
Operating Instruction
- Connect the detector to the power source, green power source indicator will flash, then the detector will enter preheat status and lasts for 3 minutes, during preheating, the detector could not detect gas leakage; 3 minutes later, the detector will enter normal detection mode, its green power source indicator will be normally on.
- When the gas concentration value in the air reaches the set alarming point, the detector will enter alarming mode, its red indicator will flash, at the same time, it sends out beeping alarm; Then, please shut off the gas supply immediately and open the window, and do not turn on any electrical appliances (including cellphone), if necessary, please ask for gas experts to eliminate the gas leakage failure.
- In the alarm state, when the gas concentration value is below the safe value, the detector will disarm the alarm automatically, if the detector send out sound-light alarm, it means the gas concentration exceed standard
- If the ring light show yellow, on all the time, and beep all the time, it means detector faults, can not detect correctly, please contact distributor for repairing.
- For daily inspection, please short press the button once, the detector enters the analog alarm mode, sends out an analog sound and light alarm signal, the red light flashes, the buzzer sounds, and then returns to the normal monitoring state. If the detector does not alarm normally, please contact the distributor or manufacturer for maintenance(For the alarm with output function, press and hold the alarm button for 15 seconds, the solenoid valve will perform the closing action, if the function is not normal, please contact the distributor or manufacturer for maintenance.
- If the service life indicator flash(flash 3 times and cycle), meanwhile, beep by 3 times and cycle, that means the sensor life is due, please contact the distributor or manufacturer for repair or buying a new one.
- Indicator light status
Mode | LED Ring Indicator | Service Life Indicator | Buzzer |
---|---|---|---|
Preheating mode | Green light flash | — | — |
Normal mode | Green light on all the time | — | — |
Testing state | Red light flash | — | Beep 4 times |
Failure mode | Yellow light on all the time | — | Beep all the time |
Alarming mode | Red light flash | — | Beep 4 times and cycle |
Service life due | — | flash | Beep 3 times and cycle |
Troubleshooting
Failure | Possible Reason(s) | Measure(s) |
---|---|---|
Green power source indicator not on | Power source cable not connected | |
correctly | Check and connect the power source cable correctly | |
Power source indicator damaged or circuit failure | Contact distributor or |
manufacturer for repair
No sound and light alarm during
self-check
| Circuit failure| Contact distributor or manufacturer for repair
No response to detected gas| Still under preheating| Wait till preheating ends
Circuit failure| Contact distributor or manufacturer for repair
Continuously alarming after turned on and time-lapse| The environment is with
large number of cigarette smoke, alcohol or volatile organic compounds like
petrol, perfume, banana oil or paints| Move to clean air spaces and try it
again
Over-long storage time| Power on and wait for 2 hours or more
Circuit failure| Contact distributor or manufacturer for repair
Notes:
For any failures cannot be resolved by yourself, do not disassemble the
detector, please contact the distributor or manufacturer for guidance.
Notes
- The large number of cigarette smoke, alcohol or volatile organic compounds like petrol, perfume, banana oil or paints inside the room may cause the detector to alarm.
- Do not use gas sample without clear concentration value to test this detector, ultra-high concentration gas will not only damage shorten the detector sensor service life but also harm human health.
- Please contact your distributor or manufacturer for help and use correct gas sample with correct concentration value to test the detector once a year.
- This product cannot be used nor stored in any environment with corrosive gases (like chlorine gas).
- Please routinely clean the dust or oil contamination on the detector surface with brush or dry soft rag.
- After long-term storage or long-time transportation, please power the detector on and wait for 24 hours or more to realize optimal performance.
- Under normal operating environment, the semiconductor sensor could work for 5 years.
Product Maintenance
- Please clean the detector at least one time a year, make sure its gas inlet is free of dust or oil contamination.
- After cleaning, install the detector back to its baseplate and conduct function check.
- Conduct an analog alarming test each half year to make sure it works normally.
- Do not expose the detector to high concentration gas sample for long time or frequently, or it will lower its sensor sensitivity or shorten its sensor life or even damage thesensor.
- The detector should be connected to stable power source.
- When detector is found in failure status, please contact the distributor or manufacturer for repair or buy a new one.
Manufacturer:
Chongqing Zorro Alert Technology Co.,Ltd.
Level 4, Building 5, No.16, Shigui Road, Jieshi Town, Ba’nan
District, Chongqing, 401346 P.R.China