mars PTAC07G130A PTAC Cooling Only With Electric Heat Owner’s Manual

June 13, 2024
MARS

mars PTAC07G130A PTAC Cooling Only With Electric Heat

Product Information

The 42 Packaged Terminal AC/HP is a versatile air-conditioning and heat pump unit that provides year-round comfort for various settings such as hotels, motels, apartments, office buildings, schools, and nursing homes. These units are designed for easy installation in most 16 x 42 wall sleeves, making them suitable for both new construction projects and replacements. With an attractive appearance and state-of-the-art technology, these units optimize energy usage while ensuring guest comfort. They are available in cooling-only and heat pump versions, and all models come with electric heat as standard. For installation flexibility, the unit can be controlled either through the on-board control panel or a wired remote thermostat. A plug-in adapter for the thermostat is included, and the unit can also be set up for a wireless thermostat or front desk control with an easy-to-connect interface. The unit features an easy-to-understand touchpad for in-room control, with LEDs indicating mode, fan operation, unit status, and setpoint. The PTAC units come with a warranty of 5 years on the compressor and 5 years on the parts. For more details on the warranty, visit www.comfort-aire.com.

Product Usage Instructions

  1. Choose an appropriate location to install the 42-packaged Terminal AC/HP unit.
  2. If required, prepare the wall sleeve according to the provided dimensions (16 x 42).
  3. Insert the unit into the wall sleeve and secure it properly.
  4. If using a wired remote thermostat, connect it to the unit using the included plug-in adapter.
  5. If setting up for wireless thermostat or front desk control, follow the provided instructions to connect the interface.
  6. Power on the unit and use the touchpad on the unit or the remote thermostat to control its functions.
  7. Select the desired mode (cooling only or heat pump) using the mode button on the touchpad or remote thermostat.
  8. Adjust the fan speed using the fan operation button on the touchpad or remote thermostat.
  9. Set the desired temperature using the setpoint buttons on the touchpad or remote thermostat.
  10. Monitor the unit status and temperature using the LEDs on the touchpad or remote thermostat.
  11. If necessary, refer to the user manual for additional features and troubleshooting information.

42” Packaged Terminal AC/HP

  • Our 42” packaged terminal air conditioners and heat pumps provide year-round comfort, room by room, for hotels, motels, apartments, office buildings, schools, nursing homes and more. Designed for quick installation in most 16″ x 42″ wall sleeves, they’re great for new construction as well as replacements.
  • Combining attractive appearance with state-of-the-art technology, these units minimize energy usage while ensuring guest comfort. Available in cooling only and heat pump versions, all models include electric heat as standard.
  • For installation flexibility, the unit is designed to be controlled either by an on-board control panel or by a wired remote thermostat. A plug-in adapter for this thermostat is included. The unit can also be set up for a wireless thermostat or front desk control with an easy-to-connect interface.
  • All functions of the unit can be controlled in-room using the easy-to-understand touchpad. LEDs correspond to mode and fan operation, indicating unit status, and the setpoint

FEATURES

  • Standard Efficiency—Provides energy efficiency and economy of cost in a streamlined and attractive modern design showcasing state-of-the-art features.
  • Environmentally Friendly—Our packaged terminal units come charged with the environmentally friendly R-32 refrigerant
  • Room Freeze Protection—When the unit senses temperatures of 50°F or lower for three minutes, heat pump models automatically activate the heating mode
  • Versatile Configuration—The unit can be optimized to a specific application through the use of dipswitches and the digital keypad; selections include setpoint limiting, front desk control, wall thermostat control, and more
  • Quiet Operation—Indoor sound reduction is achieved through the unit’s two permanently lubricated fan motors; the compressor has rubber grommet mounting
  • Fresh Air Control Arm—Allows outdoor air into the room through the filtered vent, 85 CFM
  • Easy To Service—On-board computer diagnostics help prolong the life of the unit and simplify service; LED indicator flashes error codes
  • Seacoast models—with corrosion-resistant components, see specifications inside

Warranty

5 years on the compressor, 5 years on parts See the warranty document for details or visit www.comfort-aire.com

MODEL NOMENCLATURE|
---|---
P  T| A C| 1 2| G| 1| 3 0| A
Package Terminal Unit with| AC = Cooling Only| Capacity| Source| Power| Electric Heat| Series/
Electric Heat| HP = Heat Pump| BTUH x 1000| Code| 1 = 208/230-1-60

2 = 265-1-60

| 30 = 3.0 kW

50 = 5.0 kW

| Revision

PERFORMANCE AND ELECTRICAL DATA

208/230V COOLING ONLY WITH ELECTRIC HEAT

FEATURE| PTAC07G130A| PTAC09G130A| PTAC12G130A| PTAC12G150A| PTAC15G130A| PTAC15G150A
---|---|---|---|---|---|---
Cooling BTUH| 7,000/7,200| 9,100/9,300| 11,800/12,000| 11,800/12,000| 14,300/14,500| 14,300/14,500
EER| 12.0/12.0| 11.6/11.6| 10.8/10.8| 10.8/10.8| 10.0/10.0| 10.0/10.0
Cooling Amps| 2.8/2.7| 3.9/3.6| 5.3/4.9| 5.3/4.9| 7.0/6.4| 7.0/6.4
Max. Current Amps| 3.6| 5.2| 7.7| 7.7| 11.0| 11.0
Cooling Watts| 580/600| 785/800| 1,090/1,110| 1,090/1,110| 1,430/1,450| 1,430/1,450
Electric Heater kW @ 208/230| 2,500/3,050| 2,500/3,050| 2,500/3,050| 4,135/5,050| 2,500/3,050| 4,135/5,050
Elec. Heat BTUH @ 230V| 8,300/10,200| 8,300/10,200| 8,300/10,200| 13,900/17,000| 8,300/10,200| 13,900/17,000
Dehum. Pts/Hr| 0.36/0.30| 1.69/1.37| 2.56/2.32| 2.56/2.32| 4.44/4.29| 4.44/4.29
Power Cord| LCDI-20A| LCDI-20A| LCDI-20A| LCDI-30A| LCDI-20A| LCDI- 30A
Airflow CFM| 365/424| 365/424| 412/471| 412/471| 412/471| 412/471
Indoor Sound Max dB(A)| 39/48| 39/48| 46/52| 46/52| 48/51| 48/51
Out. Sound Max dB(A)| 66| 66| 66| 66| 66| 66
Net Wt./Shipping Wt.| 91.50/102.52| 93.70/104.72| 105.82/116.85| 105.82/116.85| 95.90/117.95| 95.90/117.95

208/230V HEAT PUMP WITH ELECTRIC HEAT

FEATURE| PTHP07G130A| PTHP09G130A| PTHP12G130A| PTHP12G150A| PTHP15G130A| PTHP15G150A
---|---|---|---|---|---|---
Cooling BTUH| 6,800/7,200| 9,000/9,200| 11,800/12,000| 11,800/1,2000| 14,300/14,500| 14,300/14,500
EER| 11.9/11.9| 11.4/11.4| 10.6/10.6| 10.6/10.6| 10.0/10.0| 10.0/10.0
Cooling Amps| 2.8/2.7| 3.9/3.6| 5.3/4.9| 5.3/4.9| 7.0/6.4| 7.0/6.4
Max. Current Amps| 3.6| 5.2| 8.0| 8.0| 11.0| 11.0
Cooling Watts| 570/605| 790/805| 1,110/1,130| 1,110/1,130| 1,430/1,450| 1,430/1,450
Heat Pump BTUH| 5,800/6,000| 7,800/8,000| 10,200/10,400| 10,200/10,400| 13,200/13,600| 13,200/13,600
C.O.P. @ 47°F| 3.5/3.5| 3.4/3.4| 3.4/3.4| 3.4/3.4| 3.2/3.2| 3.2/3.2
Heating Amps| 2.5/2.3| 3.2/3.0| 4.3/3.9| 4.3/3.9| 6.0/5.5| 6.0/5.5
Heating Watts| 485/500| 670/690| 880/895| 880/895| 1210/1245| 1210/1245
Electric Heater kW @ 208/230| 2,500/3,050| 2,500/3,050| 2,500/3,050| 4,135/5,050| 2,500/,3050| 4,135/5,050
Elec. Heat BTUH @ 230V| 8,300/10,200| 8,300/10,200| 8,300/10,200| 13,900/17,000| 8,300/10,200| 13,900/17,000
Power Cord| LCDI-20A| LCDI-20A| LCDI-20A| LCDI-30A| LCDI-20A| LCDI- 30A
Dehum. Pts/Hr| 0.36/0.30| 1.69/1.37| 2.56/2.32| 2.56/2.32| 4.44/4.29| 4.44/4.29
Airflow CFM| 365/424| 365/421| 412/471| 412/471| 412/471| 412/471
Indoor Sound Max. dB(A)| 39/48| 39/48| 46/52| 46/52| 48/51| 48/51
Out. Sound Max dB(A)| 66| 66| 66| 66| 66| 66
Net Wt./Shipping Wt.| 92.59/103.62| 94.80/105.82| 95.90/117.95| 95.90/117.95| 108.03/119.05| 108.03/119.05

DIMENSIONS

OPERATING VOLTAGE

UNIT DIMENSIONS

OPERATING VOLTAGE

PERFORMANCE AND ELECTRICAL DATA

208/230V COOLING ONLY WITH ELECTRIC HEAT—SEACOAST MODELS

FEATURE| PTAC12G130ASC| PTAC12G150ASC| PTAC15G130ASC| PTAC15G150ASC
---|---|---|---|---
Cooling BTUH| 11,800/12,000| 11,800/12,000| 14,300/14,500| 14,300/14,500
EER| 10.8/10.5| 10.8/10.5| 10.0/10.2| 10.0/10.2
Cooling Amps| 5.4/5.1| 5.4/5.1| 7.0/6.4| 7.0/6.4
Max. Current Amps| 7.3| 7.3| 8.9| 8.9
Cooling Watts| 1100/1140| 1100/1140| 1450/1470| 1450/1470
Electric Heater kW @ 208/230| 3.0| 5.0| 3.0| 5.0
Elec. Heat BTUH @ 230V| 10236| 17060| 10236| 17060
Dehum. Pts/Hr| 2.32| 2.32| 3.59| 3.59
Power Cord| 20A 6-20 P| 30A 6-30 P| 20A 6-20 P| 30A 6-30 P
Airflow CFM| 405/333| 405/333| 405/370| 405/370
Indoor Sound Max dB(A)| 48/42| 48/42| 48/45| 48/45
Out. Sound Max dB(A)| 66| 66| 66| 66
Net Wt./Shipping Wt.| 108/121| 108/121| 112/126| 112/126

208/230V HEAT PUMP WITH ELECTRIC HEAT—SEACOAST MODELS

FEATURE| PTHP12G130ASC| PTHP12G150ASC| PTHP15G130ASC| PTHP15G150ASC
---|---|---|---|---
Cooling BTUH| 11,800/12,000| 11,800/12,000| 14,300/14,500| 14,300/14,500
EER| 10.6/10.5| 10.6/10.5| 10.0/10.2| 10.0/10.2
Cooling Amps| 5.4/5.1| 5.4/5.1| 6.8/6.3| 6.8/6.3
Max. Current Amps| 7.3| 7.3| 8.9| 8.9
Cooling Watts| 1100/1140| 1100/1140| 1400/1420| 1400/1420
Heat Pump BTUH| 10,800/11,000| 10,800/11,000| 13,200/13,600| 13,200/13,600
C.O.P. @ 47°F| 3.50/3.30| 3.50/3.30| 3.30/3.30| 3.30/3.30
Heating Amps| 4.5/4.2| 4.5/4.2| 5.6/5.2| 5.6/5.2
Heating Watts| 900/950| 900/950| 1155/1180| 1155/1180
Electric Heater kW @ 208/230| 3.0| 5.0| 3.0| 5.0
Elec. Heat BTUH @ 230V| 10236| 17060| 10236| 17060
Power Cord| 20A 6-20 P| 30A 6-30 P| 20A 6-20 P| 30A 6-30 P
Dehum. Pts/Hr| 2.32| 2.32| 3.59| 3.59
Airflow CFM| 405/333| 405/333| 405/370| 405/370
Indoor Sound Max. dB(A)| 48/42| 48/42| 48/45| 48/45
Out. Sound Max dB(A)| 66| 66| 66| 66
Net Wt./Shipping Wt.| 110/123| 110/123| 112/126| 112/126

  • For installations in or near coastal locations, 12,000 and 15,000 BTUH models are available in a “Seacoast” version built to withstand such extreme conditions. Corrosion-resistant coatings are applied to components, including the condenser fins, outdoor fan motor enclosure, base pan, and back grille. Additional corrosion protection is provided by stainless steel screws and aluminum end plates.
  • Treated outdoor sections successfully meet 48-hour salt spray test requirements, as well as anti-rust testing.
  • Seacoast models meet the same stringent performance specifications as all our PTACs/PTHPs and are designated by “SC” at the end of the part number.

FEATURES

OUTSTANDING WARRANTY COVERAGE
All Comfort-Aire PTACs/PTHPs are covered by a one-year parts and labor warranty. In addition, the sealed system and all functional parts are warranted to be free from defects in material and workmanship for a total of five years.
See our website for warranty details.

PTAC/PTHP ACCESSORIES

Breakdown Wall Sleeve

  • Part No. 7602-500F – Galvanized Steel
  • Part No. 7602-500PF – Polymer

Our 42” wall sleeve is constructed from galvanized steel and powder-coated for durability and aesthetic appeal. The wall sleeve is insulated and factory spot welded to minimize breaches in the cabinet surface. It contains four chassis mounting holes, four grille mounting holes, and two drain holes for an optional drain kit.

Dimensions W x H x D (inches)

  • 42” x 16” x 147/8”

Air Deflector

  • Part No. 7602-508F
    The PTAC Air Deflector directs air up and away from overhanging drapes. It saves energy by eliminating trapped air flow between the window and the curtain while increasing guest comfort levels. It is easy to install with no tools needed.

Sub Base

  • Part No. 7602-509F – Unpowered
  • Part No. 7602-509F-20A – 20 Amp Receptical
  • Part No. 7602-509F-30A – 30 Amp Receptacle

Made from galvanized steel and powder coated, our sub-base has only one piece, plus the skirting, for faster and more economical installation. Each kit contains: Sub-base main body, left and right side skirt, adjusting feet, and installation instructions.

Dimensions W x H x D (inches)

  • 423/8” x 33/4” x 45/8”

Stamped Grille

  • Part No. 7602-501F
    Our stamped grille is made from durable, lightweight aluminum and made to fit a standard 42” wall sleeve. Vents match our units to facilitate proper airflow and must used with Comfort-Aire® PTACs.

Dimensions W x H x D (inches)

  • 417/8” x 153/8” x 3/8”

Architectural Grille

Part No. 7602-505F
Our architectural grille fits a standard 42” wall sleeve. It’s formed from durable aluminum for weight reduction and weather resistance and powder coated for greater durability. Louvers are connected with high-tensile rods. The grille comes factory-assembled and includes four attachment points and two discharge air-shaping deflectors.

Dimensions W x H x D (inches)

  • 42” x 153/4” x 13/8”

Polymer Grille Full polymer grille with stainless steel hardware is ideal for any location where corrosion is an issue, especially coastal areas. Available in white, beige, alpine beige, and dark bronze.

Dimensions W x H x D (inches)

  • 42” x 157/8” x 11/8”

Photos may not portray actual color.
Grilles match our units to facilitate proper airflow and must used with Comfort-Aire® PTACs.

PTAC Remote Control

** Part No. 7602-512**
Designed to operate with our PTAC/PTHP models, this remote controls mode, temperature, and fan speed, and has a timer function.

Dimensions W x H x D (inches)

  • 17/8” x 5” x 1”

Thermostat

  • Part No. 7800-200 – used with PTAC
  • Part No. 7800-201 – used with PTHP

This thermostat is a digital, mercury-free, wired, non-programmable, electronic thermostat, compatible with PTAC/PTHP models.

Dimensions W x H x D (inches)

  • 41/2” x 33/4” x 11/16”

Wireless Wall Thermostat Part No. 7602-536A
This thermostat operates our PTAC/PTHP line, without the need to run control wires. Contains all basic thermostat functions.

Dimensions W x H x D (inches)

  • 45/8” x 33/4” x 1”

Lock Cover Part No. 7602-535
Designed for use with duct kits, where control access is not available, or any situation where wired or wireless remote system control is desired or restricted access is required. Key access is provided for service.

Shipping Dimensions W x H x D (inches)

  • 77/8” x 77/8” x 21/64”

Drain Kit Part No. 7602-506F
The drain kit, including both 90° drain tube and a 180° drain tube, can be used for either an internal or external drain and can be attached to one of two available outlets on the wall sleeve. The mounting plates are made from galvanized steel and powder-coated to match the wall sleeve.

Main Duct Kit Part No. 7602-511F
The lateral duct kit contains everything needed to convert a PTAC or PTHP for heating/cooling an adjacent room. The one-piece plenum attaches to the wall sleeve with brackets (included) and fits over the unit’s air discharge grille. The extension duct can be installed for left or right side duct applications, with a maximum extension of 4 feet. Both the plenum and the duct extension are constructed of galvanized steel with a painted finish, and they are fully lined with insulation. The air volume baffle can be adjusted to allow a 75/25 to 80/20 airflow split between the primary and secondary (adjacent) rooms. In addition to the plenum, extension duct and brackets, the kit includes a wall register, wall trim kit, end cap, hardware and instructions.

Dimensions

  • Plenum: 441/16” W x 71/8” D x 71/2” H (tallest point)

  • Extension: 475/16” W x 7” D x 31/2” H

  • Wall Register: 81/2” W x 51/4” H

  • Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice or incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer.

  • Additionally, the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations.

  • Third-party incentive and rebate programs have precise requirements as to product performance and certification.

  • All products meet applicable regulations in effect on date of manufacture; however, certifications are not necessarily granted for the life of a product. Therefore, it is the responsibility of the applicant to determine whether a specific model qualifies for these incentive/rebate programs.

PTAC models in this brochure are certified directly with the United States Dept. of Energy (D.O.E.) as meeting specifications shown. “This product complies with all California product labeling laws including, but not limited to, the Safe Drinking Water and Toxic Enforcement Act of 1986, more commonly known as Proposition 65.”