SiteWatch DW-DTWT WalkTester for Motion Detectors User Guide
- June 13, 2024
- SiteWatch
Table of Contents
Quick Start Guide
DW-DTWT | Walk-Tester for
motion detectors
INSTALLATION AND USER GUIDE
The Walk-Tester is an installation tool that helps to setup DW’s motion
detectors on-site.
Each detector has been fitted with and infra-red LED emitter.
When activation occurs, the transmitter sends a signal. This signal is then
received by the Walk-Tester and a very bright LED flashes and an alarm sounds
is also activated.
Under normal situations both the LED and the sounder can be seen and heard up
to 164ft (50m).
To verify that your detector is compatible with the Walk-Tester, remove the cover and look at the bottom of the circuit board for a blue IR LED (see figure 1 below). If the blue LED is present, the Walk-Tester will be able to communicate with the detector.
|
---|---
Fig.1 Detector’s IR emitter| Fig. 2 Walk-Tester holder and bracket
WHAT’S IN THE BOX
- 1x Walk-Tester
- 1x mount bracket
- 1x holder
- 1x quick setup guide
NOTE: Download all your support materials and tools in one place
- Go to: http://www.digital-watchdog.com/resources
- Search your product by entering the part number in the ‘Search by Product’ search bar. Results for applicable part numbers will populate automatically based on the part number you enter.
- Click ‘Search’. All supported materials, including manuals and quick start guide (QSGs) will appear in the results.
Attention: This document is intended to serve as a quick reference for the initial set-up. It is recommended that the user read the entire instruction manual for complete and proper installation and usage.
POWERING THE WALK-TESTER
Before installation, remove the battery compartment cover (fig. 3 and fig.4) and insert a 9V battery (PP3). Make sure the on/off switch on the WalkTester is set to `off’ while connecting the battery (fig. 5).
INSTALLING THE WALK-TESTER
- Remove the cover from the detector housing by loosening the stainless-steel screw at the bottom of the detector (fig. 6) to access the detector’s programming button (fig. 7).
- Enter the detector into
walk-test’ mode by pressing the program button once (fig. 7). The detector’s LED will flash out its current settings. Wait for the flashing to complete. The detector is now in
walk-test’ mode for five minutes after the last detection. After that, it will revert to normal mode. - Walk-test mode can be cancelled at any time by pressing the detector’s programming button twice.
|
---|---
Fig.6. Detector’s cover and screw| Fig.7. Detector’s programming button - Once the setup is complete, replace the detector’s cover and mount the Walk-Tester under the detector. The Walk-Tester comes with a mounting bracket holder (fig.7).
- Once the Walk-Tester is mounted properly, slightly loosen the stainless-steel screw on the bottom of the detector enough to allow for the drilled tab on the Walk-Tester bracket to slide around the screw thread.
- Gently tighten the screw to hold the Walk-Tester bracket in place (fig. 8). Please note that the Walk-Tester can be moved around the base of the detector within a 180°, allowing for visibility during walk testing.
- Once the Walk-Tester is properly installed and connected to the detector, turn the Walk-Tester on. The Walk-Tester will illuminate and sound an alarm every time the detector is activated.
- Once the test is completed, turn the Walk-Tester off and remove it and the holder from the detector. Tighten the screw on the base of the detector. See the detector’s manual for more information.
SPECIFICATIONS
POWER | 9VDC (PP3 Cell) |
---|---|
CURRENT | Standby: 0.5mA |
OPERATING TEMP | -4°F to +131°F (-20°C to +55°C) |
PROTECTION | Please note that the Walk-Tester is not waterproof and should not |
be used in wet weather conditions
DIMENSIONS| 118 x 47 x 25mm
APPROVALS
The manufacturer declares that the product supplied is compliant with the provisions of the EMC Directive 89/336/EEC amended 92/31/EEC for Electromagnetic Compatibility, and the Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC. A Declaration of Conformity in accordance with the above directives is held on file with the manufacturer.
CE MARK ****
Tel: +1866-446-3595 /
813-888-9555
Technical Support Hours: 9:00AM – 8:00PM EST, Monday through Friday
digital-watchdog.com
Rev: 12/22
Copyright © Digital Watchdog. All rights reserved.
Specifications and pricing are subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>