resideo RML10-STD Mobile Parameterization and Readout Tool Instruction Manual

June 13, 2024
resideo

Operating manual
Multilingualresideo RML10 STD Mobile Parameterization and Readout
Tool Mobile parameterization and
readout tool
RML10-STD

READ CAREFULLY BEFORE USE. STORE FOR THE ENTIRE LIFE OF THE PRODUCT.

Safety notes

1.1 Common safety instructions
These instructions must be kept for the entire service life of the device.
Hazard warnings

| Danger
Danger from swallowing small parts!
Keep the device out of the reach of children. Swallowing small parts can cause suffocation or other serious damage.
---|---
| Caution
Danger of crushing!
Use the belt clip carefully to avoid crushing.
| Caution
Danger of stabbing injuries!
Pay attention to the rod antenna when using the device to avoid eye injuries, for example.
| Caution
Danger from flying parts!
Securely fasten the device when transporting it in vehicles. Otherwise, the device could cause injuries, e.g. during a braking process.

Intended use
The mobile tool for parametrisation and readout RML10-STD is an all-in-one device for walk-by applications and AMR applications.
The RML10-STD is controlled via the RM App software, which runs on an Android® smartphone or tablet. The RML10-STD can be used for the following purposes:

  • walk-by (wM bus)
  • AMR: (RNN) set-up and configuration tool (wM bus & Infrared)
  • Meter installation & configuration tool (Infrared)

Improper use
Any use other than the use described use above and any changes made to the device constitute improper use.
Safety Instructions
Observe the technical requirements for the electrical connection and applicable national regulations. Observe the technical requirements for the connection of the data communication modules and applicable national regulations.
1.2 Safety notes on Lithium batteries
The mobile device RML10-STD is powered by a rechargeable lithium polymer battery. This battery is safe if handled properly under the parameters specified by the manufacturer. The device is maintenance-free and must not be opened.
Handling:

  • Observe the specified ambient conditions when transporting, storing and using the device.

  • Avoid mechanical damage, e.g. dropping, crushing, opening, drilling through or dismantling the batteries.

  • Avoid an electrical short-circuit, e.g. from foreign matter or water.

  • Avoid excessive thermal load, e.g. from permanent sunlight or fire.
    Charging the battery:

  • Use only the delivered USB cable to charge the battery, see Kapitel 3.4, “Battery”.

  • The battery is permanently integrated in the device and must not be removed.
    Danger caused by improper handling:

  • Incorrect handling or circumstances may result in leaks or improper operation, as well as leakage of battery contents or decomposition products. Major reactions can take place which are a risk to both health and the environment (development of gas and fire).

  • Technical defects or improper handling can lead to an uncontrolled and accelerated release of the chemically stored energy. This is usually released in the form of thermal energy, which can lead to a fire.

1.3 Disposal
With regard to disposal, the device is considered to be waste electronic equipment in the sense of the European Directive 2012/19/EU. The device must therefore not be disposed of with household waste.

  • Dispose of the device via the channels provided for this purpose.
  • Observe the local and currently valid legislation.

1.4 Warranty and guarantee
Warranty and guarantee claims can only be asserted if the equipment has been used for its intended purpose and if the applicable technical specifications and rules have been observed. All uses not in accordance with the intended purpose automatically lead to a loss of claims.

Scope of delivery

  • 1 x Mobile device RML10-STD with belt clamp and antenna
  • 1 x Positioning aid for E53205 programming adapter
  • 1 x USB cable (USB type A – USB type C, 1 m length)
  • 1 x Product accompanying document

Operation

3.1 Operating elementsresideo RML10 STD Mobile Parameterization and
Readout Tool - Operation A) Antenna
B) PWR
1)LED (indicator for device status and battery charging)
C) PWR button (device on/off)
D) Infrared interface
E) BLE
2)LED (activity indicator for Bluetooth and USB)
F) BLE button (Bluetooth on/off)
G) LED (activity indicator for Infrared)
H) button (programable)
I) USB socket (type-C)
J) Attachment for neck strap 3)

  1. PWR = Power,
    2)BLE = Bluetooth Low Energy,
    3)not included in delivery
    3.2 Switching RML10-STD on or off
  1. Press the PWR button for 2 seconds.

You hear a short beep.
If the RML10-STD is switched on: The PWR LED starts flashing green.
****If the RML10-STD is switched off: The PWR LED stops flashing (off).

3.3 Restarting RML10-STD

  1. Press the PWR button for 10 seconds.

P The RML10-STD will shut down and restart.
3.4 Battery
Charging the battery

  1. Connect the RML10-STD to a USB charger or to a USB host.

■ The power delivery option of the USB host must be enabled.
■ Use the supplied USB cable.
■ The RML10-STD supports USB Type-C BC1.2 charging mechanism with “Fast charge” feature.
■ The RML10-STD can be turned on and is fully operational even while charging.
Signals of the PWR LED

Light signal Meaning
off The RML10-STD is off.
yellow permanently The RML10-STD is off and fully charged, but still

connected to the charger.
yellow flashing| The RML10-STD is off and being charged.
green permanently| The RML10-STD is on and fully charged, but still connected to the charger.
green flashing| The RML10-STD is on and not being charged.
green and yellow flashing| The RML10-STD is on and being charged.
red permanently| Charging error
red flashing| The RML10-STD is on, low battery warning (<20 %).
red flashing and 3 seconds beep| The RML10-STD is being shut down automatically.

Table 4: Signals of the PWR LED
Battery level monitoring
The RML10-STD incorporates battery level monitoring. The battery is discharging when the RML10-STD is turned on and operational. Also, when the RML10-STD is switched off, it discharges slightly.
Low battery warning
When the battery reaches 20 % of full charge capacity the PWR LED will start flashing red.
Auto shut-down
When the battery level reaches 0 % of full charge capacity:

  • An acoustic signal sounds for 3 seconds.
  • The device will automatically shut down.
  • The LEDs will also be switched off.

3.5 Bluetooth connection
Switching Bluetooth on or off

  1. Press the BLE button for 2 seconds.

The RML10-STD is visible to other Bluetooth devices as <RML10-STD [serial number]> for 30 seconds.
You hear a short beep.
If Bluetooth is switched on: The BLE LED starts flashing blue.
If Bluetooth is switched off: The BLE LED stops flashing (off).
Pairing RML10-STD with Android® device

  1. Switch Bluetooth on.

■ Within 30 seconds you can pair the RML10-STD to your Android device.
■ You do not need a password.
■ When the RML10-STD is paired to your Android device, the BLE LED glows blue permanently.
■ If no pairing occurs within 30 seconds, Bluetooth will be switched off.
■ After disconnecting the RML10-STD from your Androiddevice, your Androiddevice automatically switches off Bluetooth.
Signals of the BLE LED

Light signal Meaning
off Bluetooth is off, USB is not active.
blue permanently A Bluetooth connection is active.

(Note: Bluetooth has priority over USB. If both are connected only Bluetooth is shown.)
blue flashing| The RML10-STD is visible via Bluetooth.
green permanently| A USB connection is active.
green and blue flashing| A USB connection is active and the RML10-STD is visible via Bluetooth.
light blue| button is under control of a connected application (e.g. RM App ) and a Bluetooth connection is active.
orange| button is under the control of a connected application (e.g. RM App) and Bluetooth is switched off
orange and light blue flashing| button is under the control of a connected application (e.g. RM App) and Bluetooth is in pairing mode

Table 5: Signals of the BLE LED
3.6 USB connection
The RML10-STD can communicate with HMA suite only via USB connection. If the RML10-STD is connected to a computer via USB, the creates two COM ports:

  • The COM port “USB Serial Port for metering devices” is intended for use with HMA suite.
  • The COM port “USB Serial Port RML10-STD” is reserved for future Windows® applications.

Signals of the BLE LED
see Kapitel 3.5, “Bluetooth connection”, Tab. 5: Signals of the BLE LED
3.7 Infrared connection
Switching infrared on

  1. Press the button.

Infrared operational modes
The RML10-STD can operate in the following infrared modes:

  • Standard assignment of the button: The radio telegrams are started at the measuring device.
  • Free assignment by the RM App: The infrared transmitter is controlled via the RM App.
  • HMA suite transparent mode: The RML10-STD is connected to a Windows® computer on which HMA suite is running.

Signals of the LED

Light signal Meaning
off The  button is in meter start mode.
yellow permanently The function of the  button is set by the RM App (RM App

mode)
yellow flashing| infrared communication in progress (only in meter start mode)
2 seconds green, 1 second beep| infrared communication was successful (only in meter start mode)
2 seconds red, 3 short beeps| infrared communication error (only in meter start mode)
2 seconds yellow, 5 short beeps| infrared device reported error (only in meter start mode)

Table 6: Signals of the LED
Positioning of the RML10-STD
resideo RML10 STD Mobile Parameterization and Readout Tool -
Positioning Distance between (A) and (B) maximum 15 cm.
3.8 Retrofiting E53205 programming adapter
The programming adapter for E53205 is by default intended for use with the WFZ .IrDA-USB. To use the programming adapter with the RML10-STD, the positioning guide of the programming adapter must be replaced.
Warning
Carry out the following steps very carefully! There is a risk that the retaining bars or the positioning guide will break off.resideo RML10 STD
Mobile Parameterization and Readout Tool - Positioning 1

  1. Remove the O-rings (A).

  2. Remove the positioning guide for the WFZ.IrDA-USB (B).

  3. Mount the positioning guide for the RML10-STD (C).
    ■ The guide nose of the positioning guide (D) must point upwards.

  4. Mount the O-rings (A).

3.9 Programming E53205 with RML10-STDresideo RML10 STD Mobile
Parameterization and Readout Tool - Positioning 2

  1. Insert the E53205 (F) into the programming adapter (E).

  2. Place the RML10-STD (A) on the positioning guide (D).
    ■ The guide nose (C) of the positioning guide must be in the recess (B) on the back of the RML10-STD.

  3. To switch on the RML10-STD, press the PWR button (G).

  4. To activate the infrared interface of the RML10-STD, press the button (H).

  5. Perform the programming with the RM App.

Technical specifications

General information

Dimensions (W x H x D in mm)| without antenna: 65 x 136 x 35
with antenna: 65 x 188 x 35
Weight| 160 g
Housing material| ABS plastic
IP protection rating| IP54
Ambient conditions
During operation| -10 °C … +60 °C, < 90 % RH (without condensation)
During transport| -10 °C … +60 °C, < 85 % RH (without condensation)
During storage| -10 °C … +60 °C, < 85 % RH (without condensation)
Wireless M-Bus (EN 13757)
Independently controlled radio transceivers| 2
RSSI signal strength measurement| yes
AES encryption| 128 bit
Supported modes| S1, S1-m, S2: radio frequency (868.3 ±0.3) MHz, transmission
power (max. 14 dBm / typ. 10 dBm)
C1, T1: radio frequency (868.95 ±0.25) MHz , transmission power
(none)
Bluetooth
Bluetooth standard| Bluetooth 5.1 Low Energy
Radio frequency| 2.4 GHz (2400 … 2483.5) MHz
Transmission power| max. +8 dBm
USB
USB specification| 2
USB connector| USB Type-C socket
Infrared
Infrared Physical Layer| SIR
Baud rate| max. 115200 / typ. 9600
Range| max. 15 cm
Angle| min. cone ±15°
Battery
Type| rechargeable, non-replaceable lithium-polymer battery
Nominal capacity| 2400 mAh (8.9 Wh)
Battery charging| via USB socket (type C); USB cable (type C) is supplied;
auto detection of USB BC1.2, SDP, CDP, DC
Charge voltage| 5 V DC
Charge current| max. 2300 mA
Temperature during charging| 0 °C … +45 °C

Simplified EU Declaration of Conformity

**** Ademco 1 GmbH hereby declares that this device complies with directive 2014/53/EU (RED).
The full text of the EU Declaration of Conformity is available at the following Internet address: https://homecomfort.resideo.com/sites/europe
There are no restrictions on the use of these products in EU countries.

Manufactured for and on behalf of
Pittway Sàrl, Z.A., La Pièce 6,
1180 Rolle, Switzerland
For more information
homecomfort.resideo.com/europe
Ademco 1 GmbH, Hardhofweg 40,
74821 MOSBACH, GERMANY
Phone: +49 6261 810
Fax: +49 6261 81309
Subject to change.
RML10-oi-en1h2602GE23R0223
© 2023 Resideo Technologies, Inc. All rights reserved.
Doc. no.: LUM5-HWTS-DE0-QTOOL-A