OXBOX JMM5A0A24M21SA Wall Mount Air Handlers 2 3 Ton Cooling Heat Pump Owner’s Manual

June 13, 2024
Oxbox

OXBOX JMM5A0A24M21SA Wall Mount Air Handlers 2 3 Ton Cooling Heat Pump

Product Information

The product is a JMM5A-SUB-1A. It is available in three models:

JMM5A0A24M21SA, JMM5A0B30M21SA, and JMM5A0B36M31SA. The product dimensions vary depending on the model. The unit weight and shipping weight also vary.

The product specifications include the rated volts/ph/hz, indoor coil type, rows – F.P.I., face area, tube size, refrigerant control, drain conn size, indoor fan type, diameter-width, number used, drive – no speeds, cfm vs. in. w.g., number of motors – H.P., motor speed R.P.M., volts/ph/hz, and F.L. amps.

The product also has information about the filter type recommended, refrigerant line connections, dimensions, and weight.

The user manual also provides airflow performance data for each model at different external static pressures and speeds.

Product Usage Instructions

  1. Ensure that the minimum unit clearance to combustible material is maintained as specified in the table provided in the user manual.
  2. Install the product according to the specified dimensions and clearance data mentioned in the user manual.
  3. Connect the gas line with a 3/4-inch braze coupling or connector.
  4. Connect the refrigerant lines with appropriate brazed couplings or connectors (3/4-inch for gas and 3/8-inch for liquid).
  5. Install the recommended type of filter (throwaway) with the specified size and thickness (1 – 16×20 – 1 inch).
  6. Follow the specified electrical requirements for rated volts/ph/hz.
  7. Adjust the airflow performance settings based on the desired external static pressure and speed. Refer to the airflow performance table in the user manual for reference.
  8. Regularly maintain and clean the product as per the manufacturer’s recommendations.

Note: For specific installation and operating instructions, refer to the complete user manual provided with the product.

Wall-Mount

Air Handlers

2 – 3 Ton Cooling/Heat Pump

  • JMM5A0A24M21SA
  • JMM5A0B30M21SA
  • JMM5A0B36M31SA

Dimensional and Clearance Data

MINIMUM UNIT CLEARANCE TABLE

 | TO COMBUSTIBLE MATERIAL (REQUIRED)| ****

SERVICE CLEARANCE (RECOMMENDED)

SIDES| 0″| 0″
FRONT| 0″| 24″
BACK| 0″| 0″
INLET DUCT| 0″| 0″
OUTLET DUCT| 0″*|

  • 0 ” FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALLED
PRODUCT DIMENSIONS  inch (mm) Unit weight/ Shipping Weight [LBS(kg)]
  Height
H W
JMM5A0A24M21SA 36-1/2″ (928)
(242) TXV
JMM5A0B30M21SA 39-1/2″ (1004)
(242) TXV
JMM5A0B36M31SA 39-1/2″ (1004)
(242) TXV

PRODUCT SPECIFICATIONS

MODEL JMM5A0A24M21SAA JMM5A0B30M21SAA JMM5A0B36M31SAA
RATED VOLTS/PH/HZ. 208-230/1/60 208-230/1/60 208-230/1/60
RATINGS See O.D. Specifications See O.D. Specifications See O.D.

Specifications
INDOOR COIL — Type| Plate Fin| Plate Fin| Plate Fin
Rows — F.P.I.| 5 – 11| 5- 14| 5- 14
Face Area (sq. ft.)| 2.20| 3.00| 3.00
Tube Size (in.)| 9/32| 9/32| 9/32
Refrigerant Control| TXV| TXV| TXV
Drain Conn Size (in.)| 3/4 NPT| 3/4 NPT| 3/4 NPT
DUCT CONNECTIONS| See Outline Drawing| See Outline Drawing| See Outline Drawing
INDOOR FAN — Type| Centrifugal| Centrifugal| Centr ifugal
Diameter-Width (In.)| 10-5/6 X 6-1/7| 10-3/5 X 9-10/7| 10-3/5 X 9-10/7
No. Used| 1| 1| 1
Drive – No Speeds| Direct – 5| Direct – 5| Direct – 5
CFM vs. in. w.g.| See Fan Performance Table| See Fan Performance Table| See Fan Performance Table
No. Motors — H.P.| 1 – 1/3| 1 – 1/2| 1 – 1/2
Motor Speed R.P.M.| 1050| 1050| 1050
Volts/Ph/Hz| 208-230/1/60| 208-230/1/60| 208-230/1/60
F.L. Amps FILTER| 1.9| 2.7| 2.7
Filter Furnished?| No| No| No
Type Recommended| Throwaway| Throwaway| Throwaway
No.-Size-Thickness| 1 – 16X 20 – 1 in.| 1 – 20X 20 – 1 in.| 1 – 20X 20 – 1 in.
REFRIGERANT

Ref. Line Connections

| R-410A

Brazed

| R-410A

Brazed

| R-410A

Brazed

Coupling or Conn. Size — in. Gas                      3/4| 3/4| 3/4
Coupling or Conn. Size — in. Liq.                       3/8| 3/8| 3/8
DIMENSIONS| H x W x D| H x W x D| H x W x D
Crated (In.)| 39-3/8×22-6/7×17-1/3| 42-4/7×24-1/4×21-2/7| 42-4/7×24-1/4×21-2/7
Uncrated| 36-1/2×20-1/2×15| 39-1/2×22×19| 39-1/2×22×19
WEIGHT|  |  |
Shipping (Lbs.)/ Net (Lbs.)| 93/79| 97/115| 97/115

Performance and Electrical Data – JMM5A0A24–B36

AIR FLOW PERFORMANCE (Standard CFM)

MODEL SIZE BLOWER SPEEDS EXTERNAL STATIC PRESSURE (INWC.)
0 0.1 0.2

0.8




JMM5A0A24M21SA

| TAP 5| 913| 881| 848| 818| 792| 763| 731| 691| 650
TAP 4 – Factory| 825| 787| 753| 717| 682| 650| 617| 580| 540
TAP 3| 737| 700| 663| 630| 589| 550| 511| 474| 436

  • TAP 2| 675| 632| 596| 555| 521| 480| 440| 399| 366
    TAP 1| 590| 548| 499| 455| 430| 368| 338| 309| 263


JMM5A0B30M21SA

| TAP 5| 1362| 1325| 1266| 1238| 1197| 1159| 1119| 1080| 1040
TAP 4| 1282| 1242| 1176| 1151| 1111| 1071| 1028| 975| 936
TAP 3| 1267| 1225| 1143| 1120| 1078| 1036| 993| 942| 897
TAP 2 – Factory| 1157| 1111| 1052| 1016| 971| 929| 884| 842| 802
TAP 1| 1077| 1028| 965| 932| 886| 850| 804| 768| 732




JMM5A0B36M31SA

| TAP 5| 1362| 1325| 1266| 1238| 1197| 1159| 1119| 1080| 1040
TAP 4 – Factory| 1282| 1242| 1176| 1151| 1111| 1071| 1028| 975| 936
TAP 3| 1267| 1225| 1143| 1120| 1078| 1036| 993| 942| 897
TAP 2| 1157| 1111| 1052| 1016| 971| 929| 884| 842| 802
TAP 1| 1077| 1028| 965| 932| 886| 850| 804| 768| 732
Shaded boxes represent airflow outside the required 300-400 cfm/ton.

  • When JMM5A0B24MM21SA uses the 18 KBTU outdoor unit, select SCFM between 450 and 675.

NOTES:

1.         Airflow based upon dry coil at 230V with no electric heat, no filter. For 24, 30, and 36 sizes, airflow at 208V is approximately the same as 230V because the mult-tap ECM motor is a constant torque motor. The torque doesn’t drop off at the speeds in which the motor operates.

2.         Airflow is equivalent for front or bottom return configurations.

3.         SCFM is nearly the same with cooling performance airflow, the gap is in the 1 to 2%.

ELECTRICAL DATA

JMM5A0A24M21SA

Heater Model No

| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater|  |  |  |  | 2.4| 15|  |  |  | 2.4| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 28.5| 30| 3.8| 12800| 18.0| 25.0| 30
BAYHTRJ508BRKA
| 1/1| 7.5| 25600| 31.2| 41.5| 45| 5.6| 19200| 27.1| 36.3| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 54.5| 60| 7.5| 25600| 36.1| 47.6| 50
ELECTRICAL DATA

JMM5A0B30M21SA

Heater Model No

| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater|  |  |  |  | 3.4| 15|  |  |  | 3.4| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 29.5| 30| 3.8| 12800| 18.0| 26.0| 30
BAYHTRJ508BRKA
| 1/1| 7.5| 25600| 31.2| 42.5| 45| 5.6| 19200| 27.1| 37.3| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 55.5| 60| 7.5| 25600| 36.1| 48.6| 50
ELECTRICAL DATA

JMM5A0B36M31SA

Heater Model No

| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater|  |  |  |  | 3.4| 15|  |  |  | 3.4| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 29.5| 30| 3.8| 12800| 18.0| 26.0| 30
BAYHTRJ508BRKA
| 1/1| 7.5| 25600| 31.2| 42.5| 45| 5.6| 19200| 27.1| 37.3| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 55.5| 60| 7.5| 25600| 36.1| 48.6| 50

Mechanical Specifications

STANDARD FEATURES

  • Front or bottom return air

  • Painted finish on galvanized steel

  • Sturdy polycarbonate drain pans

    • The JMM5 wall mount air handler has factory-installed
      drain pans and is shipped for upflow applications only.
  • 208/230 – VAC operation

  • Multi-speed direct drive blower

    • Constant torque ECM motor with fan-off time delay
      programming
  • Factory-installed R-410A thermal expansion valve

  • Stud or wall mounting tabs

  • Fully insulated cabinet

  • 3/4″ NPT primary and secondary drains

  • All – aluminum tubes & fins

OPTIONAL ACCESSORIES

  • 5, 7.5, and 10 kW single-phase electric heaters
    • Circuit breakers are standard on all single phase 5, 7.5, and 10 kW heaters.
  • R-22 TXV conversion kit – 2AYTXVH3G2436
  • R-410 TXV kit -4AYTXVH3G2436
  • Front louver panel 20.5″ width – BAYFRTLOUPNL20 (1-Pack)
  • Front louver panel 22″ width – BAYFRTLOUPNL22 (1-Pack)
  • Return air/service wall panel – BAYTMMWALLPNL1 (20-Pack)
  • Return air/service wall panel – BAYTMMWALLPNLS (1-Pack)

The Manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Oxbox User Manuals

Related Manuals