Chang zhou shi lian ji dian zi co ltd 2BAO2 Electronic Cabinet Lock Instruction Manual

June 13, 2024
Chang zhou shi lian ji dian zi co ltd

Chang zhou shi lian ji dian zi co ltd 2BAO2 Electronic Cabinet Lock

User type

User type quantity Functions

Manager card

| ****

5

| ****

Add, delete, configure and unlock


User card

| ****

13

| ****

Unlock

Technical parameter

Voltage DC 6.0 V     (1.5V alkaline batteries *4)
Quiescent current <20uA
Operation current <180mA
Card standard M1/NFC
User card capacity 18
Operating temperature -10℃~60℃
Operating humidity 10%RH ~ 90%RH

Operations

Configure Operations Notes
Reset to factory default ****

Push reset button for 2s

|



Double mode

| Push reset button for 2s and sound “Di-”, then keep button pushed for

another 3s for double mode with sound

“Di-Di-” indication

| Unlock with two user cards. The manager card can unlock directly.


First manager card

| ****

Read any card

| The manager card can be set directly in the default state.


Add user card

| Read manager one time, then read cards to add for user card.| You can add user cards continuously.


Add manager card

| Read manager three times, then read cards to add for manager card.| You can add manager cards continuously


Delete user card

| ****

Read manager five times.

| ****

Delete all user cards.

Normal open when battery empty| ****

Read manager nine times

| “Di-” indicate function disable “Di-Di-” indicates function

enable

Reset to factory default
Press the button for about 2 seconds, and the buzzer will sound one time. At this time, all cards are cleared and reset to factory default.

Double mode
Press the button for about 2 seconds, and the buzzer will sound one time. Then keep the button pressed for another 3 seconds for double mode with the sound “Di-Di-” indication. At this time, all cards are cleared. You must to set cards again and unlock with two user cards.

Manager card

  1. The first manager card can be set directly in the default state.
  2. Add other manager cards: Read the manager card 3 times, then read cards to add for the manager card.
  3. The maximum quantity of manager cards is 5. (Include the first manager card).
  4. The manager cards is used to add, delete, configure, and unlock.

Add user card

  1. Read manager card one time, then read cards to add for user card.
  2. The maximum quantity of user cards is 13.

Add user card
Read the manager card 5 times and wait for 5s, then sound “Di-Di-Di-Di-Di-”, and all user cards be deleted.

Normal open when battery low
Read the manager card 9 times, “Di-” indicates this function is disabled, and “Di-Di-” indicates the function is enabled. (Default is enabled)

Low battery indication

  1. After the battery is low, the buzzer will sound “Di-Di-Di-Di-”, and “Di-Di-Di-Di-” when unlocking. Please replace the battery as soon as possible.
  2. When the Low battery normal open function is enabled, the door lock will not lock after unlocking with a low battery. You must replace the battery to use this lock again.

Installation of fan-shaped door

Install lock body
Place the lock body correctly,(as shown in picture 2) to fix the lock body using 4pcs 4 * 40 round head self-tapping machine screws, and install 4pcs AAA alkaline batteries.

Install lock catch
Place the lock catch in the correct position on the inside of the cabinet wall, (as shown picture 5). After closing the door, the lock catch can be locked into the lock ; fix it with 2pcs 4 * 20 round head self-tapping screws.

Installation of moving door

Install lock body
Place the lock body correctly,(as shown pictures7) to fix the lock body using 4pcs 4 * 40 round head self-tapping machine screws, and install 4pcs AAA alkaline batteries.

Install lock catch
Place the lock catch in the correct position on the inside of the cabinet wall, (as shown picture 10). After closing the door, the lock catch can be locked into the lock ; fix it with 2pcs 4 * 20 round head self-tapping screws.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Warning

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.