GAGGENAU VG415215 Gas Cooktop Instruction Manual
- June 13, 2024
- Gaggenau
Table of Contents
VG415215
Instruction Manual
Included accessories
1 x WOK attachment ring
Optional accessories
wP400001:
Wok pan
Installation Accessories
CKG410000:
1 knob, gas,black
CKG410010:
1 knob. gas. stainless steel
VA420004: Connecting strip Serie 400. flush, short
VA420010: Connecting strip Serie 400. top. short
VA440010: Appliance cover Vario 400 series
Vario gas cooktop 400 series 38 cm, Natural gas 20 mbar
VG415215
VG415215
- Multiting burner with 6 KW
- Full electronic power level regulation on 12 levels
- Solid stainless steel knob, also selectable with black robust finishing, for precise control and personalisation
- Precision crafting of 3 mm stainless steel
- For surface installation with a visible edge or for flush installation
- Multiting burner with 6 KW
Full electronic power level regulation on 12 levels
Solid stainless steel knob, also selectable with black robust finishing, for
precise control and personalisation
Precision crafting of 3 mm stainless steel
For surface installation with a visible edge or for flush installation
Precise and reproducible flame size
Automatic fast ignition, electronic flame monitoring with automatic reignition
Simmer function for cooking on a very low output level
Can be combined perfectly with other Vario appliances of the 400 series
Cocking zones
- multi-ring wok burner (300 W – 6000 W), suitable for pots up to max. 6 32 cm.
**Handing
**
Control knobs with dluminated ring, cooking zone and output level markings.
One-handed operation.
Full ebectronic control in 12 output levels for exact power level adjustment
plus simmer function.
Automatic fast ignition.
Features
Simmee function. Cast pan support with flat. continuous pot surface.
Brass burner tings.
Safety
Electronic flame monitoring with automatic fe-4gnition.
Residual heat indication.
Salety shut-off.
Planning notes
Depending on the type of installation (surface-mounted o¢ fiush-mounted, with
or without an appliance cover), the specific location of the cut-out and the
knob positions may vary.
The drawing “Installation of the control knob’ must be observed if the panel
ie more than 23 mm thick (there must be a recess at the rear). 1f combining
several Vario appliances of the 400 aeries, a connection strip VA 420 muet be
placed between the appliances. Depending on the type of installation. the
corresponding connection sirip must be provided.
The bearing capacity and stability, in the cape of thin worktope in
particular, must be supported using suitable substructures. Take into account
the appliance weight and additional loads.
Additional instructions for flush installation:
Installation is possible in worktops made of stone, synthetics or solid wood.
Heat resistance and watertight sealing of the cut edges must be observed.
Concerning other materials please consult the worktop manufacturer. The groove
must be continuous and even, so that uniform placing of the appliance on the
gasket is ensured. Do not use discontinuous lining.
The joint width may vary due to size tolerances of the combinations and of the
worktop cut-out.
If installing several appliances in individual cut-outs allow for a division
bar of minimum 50 mm between the individual cut-outs.
Special nozzles can be ordered as spare parts.
Plan for an electrical connection (the appliance is not operable without power
supply).
Air intake from above.
No intermediate shelf required.
Rear panel and wall trims must be heat-resistant and consist of a non-
flammable material.
A minimum clearance of at least 150 mm from adjacent heat-sensitive furniture
or contact surfaces must be observed or thermal insulation fitted.
If operated next to the downdraft ventilation VL 414, the ventilation moulding
AA 414 is recommended to ensure maximum performance of the cooktop.
With a total connected load of more than 11 kW local regulations concerning
room ventilation, room size and combination of extraction or recirculation
hoods must be observed.
The minimum distance between the cooktop surface and a cabinet above, out of
combustible material, needs to be 70 cm.
The minimum distance to a ventilation above is shown at the planning hints for
the individual ventilation product.
Appliance can be snapped into the worktop from above.
Appliance weight: approx. 14.
Connection
Total connected load gas 6.0 KW.
Total connected load electric 15.0 W.
Connecting cable 1.4 m with plug.
VG415215 A: When
installing with appliance cover consider the deeper cut-out (observe separate
planning notes)
B: 3.6°5 mm 6.5°5 mm in combinations with frameless induction cooktops
Measurements in mm
Installation of the control knob; surface mounting Installation of the
control knob; flush installation A: When instaling with apphance caver, take the deeper cut-
out into consideraban (observe separate planning nates)
measurements in men
Longitudinal section A: 3,5°°°
6.5°in combinations with frameless induction hobs
B: Fill with silicone
measurements in mm
Cross-section measurements
in men
Installation with appliance cover, surface mounting measurements in men
A 3.5°°
6.5°°5in combinations with frameless induction hobs
B: Fill with silicone
When installing with appliance cover, pay attention to the deeper cutout and
the front and rear groove width. measurements in mm
View from above measurements in men
A: When installing with appliance cover, take the deeper cut-out into
consideration (observe separate planning notes) measurements in mm
Installation with appliance cover, surface mounting Installation with appliance cover, flush
mounting
Installation with appliance cover, flush mounting
2023-10-04