Irrigationglobal R20-QM 3W Quick Pressure Relief Valve
Product Information
The A.R.I. R20-QM 3W Quick Pressure Relief Valve is an automatic control valve
designed for relieving pressure in a hydraulic system. It is equipped with a
hydraulic pilot valve that opens to release upstream pressure when it exceeds
a preset value. This valve remains closed as long as the upstream pressure is
below the set pressure. The valve is externally plumbed and can be integrated
into larger systems.
For detailed installation, operation, and maintenance instructions, please
refer to the product manual available at
www.irrigationglobal.com.
Product Usage Instructions
Safety Instructions
- Ensure that all installation, operation, and maintenance activities are carried out by qualified workers, technicians, and/or contractors who adhere to relevant safety standards.
- Take extra precautions when dealing with hot or hazardous liquids or in hazardous environments to prevent bodily harm or property damage.
- Comply with occupational safety and health (OSH) instructions, wearing appropriate safety equipment such as helmets, goggles, gloves, etc.
- Use only standard tools and equipment operated by qualified operators during installation, operation, and maintenance.
- Prior to any action on the product, carefully read and follow the safety, installation, and operation instructions provided in the product manual.
Installation
Follow these steps for proper installation of the A.R.I. R20-QM 3W Quick Pressure Relief Valve:
- Refer to the control diagram in the manual for component illustration.
- Ensure that the valve is plumbed externally in the hydraulic system.
- Install the valve according to good engineering practices and in compliance with all relevant local standards.
- If applicable, take extra safety measures when working with hot or hazardous liquids.
Adjusting the Release Pressure Set Point
To adjust the release pressure set point of the valve, follow these steps:
- Refer to the product manual for details on adjusting the release pressure set point.
Operation Instructions
Ensure that you understand the operation of the A.R.I. R20-QM 3W Quick Pressure Relief Valve before use.
- The valve will remain closed as long as the upstream pressure is below the preset value.
- When the upstream pressure exceeds the preset value, the hydraulic pilot valve will open, releasing the excess pressure.
Troubleshooting
Refer to the troubleshooting section in the product manual for guidance on
resolving any issues with the A.R.I. R20-QM 3W Quick Pressure Relief Valve.
Control Loop Drawings
For control loop drawings and additional information, refer to the product
manual available at www.irrigationglobal.com.
3W Quick Pressure Relief Valve
The following is a step-by-step narrated description of the A.R.I. R20-QM 3W
Quick Pressure Relief Valve installation, operation and maintenance processes.
The A.R.I. R20-QM 3W quick pressure-relief valve is an automatic control valve
plumbed externally with a particular hydraulic pilot valve that opens to
release upstream pressure above a preset value. The quick pressure relief
valve remains closed while the upstream pressure is below the set pressure.
Refer to the control diagram for component illustration.
Disclaimer
This document is an Installation, Operation and Maintenance (IOM) manual
for Aquestia Ltd. The information enclosed herein contains restricted,
privileged, proprietary, and confidential information, intended only for usage
by authorized Aquestia technicians. If you are not a qualified technician, you
must not take any action in reliance upon this document, unless otherwise
permitted in writing by Aquestia Aquestia has made every effort to ensure that
this document is accurate; Aquestia disclaims liability for any inaccuracies
or omissions that may have occurred. All the procedures, drawings, pictures,
and/or any other information provided in this document are presented as
general information only; they can be altered, removed or changed without
Aquestia’s prior written approval. Aquestia makes no commitment to update or
keep the information in this document current and/or up-to-date, and reserves
the right to make improvements, alterations and/or modifications to this
document and/or to the products described in this document, at any time
without providing any notice with respect thereto. Nothing in this Disclaimer
derogates in any way whatsoever from the confidential nature of any document
enclosed hereto, including for the avoidance of doubt, any mistake or clerical
error or other error. None of the procedures provided in this Disclaimer
and/or in any document enclosed hereto may be used in any form or by any means
without the prior written consent from Aquestia If you received this
Disclaimer and/or in any document enclosed hereto in error or by mistake or if
this Disclaimer and/or in any document enclosed hereto is not intended for
you, please notify Aquestia in writing immediately.
Aquestia assumes that all users understand the risks involved within this
Disclaimer and/or in any document enclosed hereto. Aquestia accepts/assumes no
liability whatsoever, whether caused by: accessing and/or relying upon this
Disclaimer and/or in any document enclosed hereto including without limitation
any links, procedures or materials. shall NOT assume any liability for any
costs, direct or indirect, including loss of income, loss of profits and/or
goodwill, legal actions and/or damages of any kind whatsoever including any,
damages accidents, equipment damage or bodily injury resulting from and/or
related to any of the following:
- product has not been duly installed and thereafter maintained in strict compliance with its designated Maintenance Instructions and/or any other installation and operation manuals provided by Aquestia for the product and/or applicable ordinances and/or codes;
- Repairs made in and to the products by personnel not authorized by Aquestia
- Maintenance or repairs using parts or components other than those specified by Aquestia and in their original condition.
- Operating the products in ways other than the operating procedures described in the manuals provided by Aquestia, or resulting from not following the cautionary remarks and warnings in the product manual.
- Improper storage, workplace conditions and environmental conditions which do not conform to those stated in the Product manual.
- Fires, earthquakes, floods, lightning, natural disasters, or acts of God.
Aquestia does not warrant and hereby disclaims any express or implied warranties that the product will work properly in environments and applications other than its original design purpose, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for any other particular purpose. Except as provided herein and to the full extent permitted by law, Aquestia shall not be responsible and/or liable for direct, special, incidental or consequential damages or loss resulting from any breach of the above or under any other legal theory. This document does not replace any certified drawing, procedure or information provided by Aquestia in reference to a specific customer, site or project. All rights reserved.
Safety Instructions
General
- Aquestia products always operate as components in a larger system. It is essential for the system designers, installers, operators, and maintenance personnel to comply with all the relevant safety standards.
- Installation, operation or maintenance of the product should be done only by qualified workers, technicians, and/or contractors using only good engineering practices, complying with and observing all conventional safety instructions in order to minimize risk and/or danger and/or hazard to workers, the public or to property in the vicinity in accordance with all relevant local standards.
- Extra safety considerations should be taken with hot and hazardous liquids or in hazardous environments’ applications to avoid bodily/physical harm and damage to public or private property.
- All individuals installing operating and/or handling the products including all workers should at all times adhere to the occupational safety and health (OSH) instructions and wear safety helmets, goggles, gloves, and any other personal safety equipment required by the local standards and regulations.
- Use only appropriate standard tools and equipment operated by qualified operators when installing, operating, and maintaining the product.
- Prior to installation, operation, maintenance or any other type of action carried out on the product, read carefully the safety, installation, and operation instructions of the product.
- Please note:
- Pressurized fluid and/or gas may be discharged from the product without prior warning. Make sure that the product’s outlet port is not directed toward electrical elements (pumps) or people.
- The pressurized fluid and/or gas that can be discharged from the product may create high noise levels. Take this into consideration when installing the product in areas sensitive to noise.
- Always open and close valves slowly and gradually.
- Please note that the maximum working pressure indicated at the product’s specifications table doesn’t include pressure changes caused by water hammer and pressure surge effects. Use the product only according to its designated pressure rate specifications.
- Use the product only for its intended use as designed by Aquestia Any misuse of the product may lead to undesired damages and may affect your warranty coverage. Please consult with Aquestia prior to any nonregular use of this product and make no change or modification to the product without prior written consent to be provided by Aquestia at Aquestia’s sole discretion.
- Please note that Aquestia shall NOT assume any liability with respect to any damage losses and/or expenses caused to any person and/or property whatsoever unless the product has been duly installed and thereafter maintained in strict compliance with its designated maintenance Instructions and/or any other installation and operation manuals provided by Aquestia for the product and/or applicable ordinances and/or codes.
Handling
- Shipping and handling of the product must be done in a safe and stable manner and in accordance with the relevant standards and regulations.
- For lifting and positioning the product, use only approved lifting equipment operated by authorized employees and contractors.
- Prior to the installation visually verify that the product was not damaged during shipment to the installation site.
Installation
- Install the product according to the detailed Installation Instructions provided it by Aquestia and according to the description given in this manual.
- The user should install a manual Isolation Valve under the product’s inlet port.
- In all installation sites, the user should enable good visibility and verify that the work and auxiliary equipment used are done in accordance with the relevant local authorized standards. Extra safety considerations should be taken on hazardous environment sites.
- Check and re-tighten the bolts connecting the product to the pipeline during commissioning and before operating the product for the first time.
Commissioning and operation
- Read carefully the operation instructions prior to any attempt to operate the product.
- Observe the safety stickers on the product and never perform any operation contradicting the instructions given.
- In order to achieve maximum performance and smooth operation of the product it is crucial to perform the startup and first operation procedures exactly as described in this manual.
- In cases where a formal commissioning procedure is required, it should be done by an authorized Aquestia technician prior to the first operation of the product.
Maintenance
Before any maintenance or nonregular operation please read the following:
-
Servicing the product should be done only by qualified technicians for this type of work.
-
Make sure that you know the exact type of the system’s fluid. Act accordingly and comply with all the relevant standards and regulations set for handling this type of fluid.
-
Before disconnecting the product from the system and before releasing the residual pressure do NOT:
- loosen or unscrew the product bolts;
- remove any protection cover;
- open any service port.
-
Before any maintenance or nonregular operation shut off the Isolation valve and release the residual pressure:
A. For air valves with pressure release outlet, slowly open the pressure release plug or the ball valve and make sure that all pressure is released. Please note that some air release valves, especially the waste water models, may contain significant volume of compressed gas with accumulated energy!
B. For air valves without a pressure release outlet, slowly unscrew the flange bolts until all the pressure is released from the valve. -
Make sure the air valve is empty of all liquid prior to commencing maintenance.
-
Remove the product from the line only after ensuring that internal pressure has been released.
-
Place warning signs around the work area as required by the local standards and procedures.
-
Inspect the product’s safety stickers and replace any damaged or faded stickers.
-
Manual cleaning of the product and/or its components using high water pressure or steam should be performed in accordance with its specific cleaning instructions, the local standards and regulations and without endangering the operator or the vicinity
-
Manual cleaning of the product and/or its components using acid or other chemical agents should be performed in accordance with the specific cleaning instructions, the relevant safety instructions for using that chemical as given by its supplier, the local standards and regulations and without endangering the operator or his vicinity.
-
For products used in potable water systems if it is required to disinfect the product, do so according to the local water authority standards and regulations before putting the product into service.
Before returning to regular operation
- Re-assemble any protection covers or protection mechanisms removed during service or maintenance operations.
- Make sure that all the tools, ladders, lifting devices, etc. used during the maintenance procedures are taken away from the product area and stored.
- Remove grease and fat material residues in order to avoid slipping.
- In order to return the product to regular operation, follow the First Start-up Operation instructions as detailed in your user manual.
Installation
- It is recommended that the valve be easily accessible as well as clearly marked to prevent damage.
- Before installing the valve, flush the pipeline to remove scale, dirt, and other particles that might affect the valve’s performance.
- Install the valve as indicated by the arrow on the valve’s cover, showing the flow direction.
- It is recommended to install isolation valves, upstream and downstream of the control valve.
- If fitted (optional), open ball lever isolating valves [b1] and [b2].
- Turn the locking nut on the pilot valve adjustment bolt [p] anti-clockwise, until it touches the bottom of the adjustment bolt head.
- Turn the adjustment bolt on the pilot valve [p] clockwise for maximum tension on the spring (closes valve hydraulically, with a high release set point).
- Turn on the water supply to the valve.
- Check for leaks; tighten bolts & fittings if necessary.
Adjusting the Release Pressure Set Point
-
Make sure the water pressure is at working condition.
-
Turn the adjusting bolt of the pilot valve [p] OUT (anti-clockwise), 1/4 turn at a time, allowing 2-5 seconds between turns for the valve to respond. Monitor the pressure gauge [g] and continue the process until water just starts dripping from the main valve outlet.
-
As the water starts dripping through the main valve, turn the adjustment bolt [p] IN (clockwise) one full turn. The release set point is now 5 to 10m above the current system pressure.
a) To increase the pressure release set point, turn the adjusting bolt of the pilot valve [p] clockwise, 1/4 turn at a time, allowing 2-5 seconds between turns for the valve to respond. Monitor the pressure gauge [g] and continue the process until the required downstream pressure limit is achieved.
b) To decrease pressure release set point, turn the adjusting bolt of the pilot valve [p] anticlockwise, 1/4 turn at a time, allowing 2-5 seconds between turns for the valve to respond. Monitor the pressure gauge [g] and continue the process until the required downstream pressure limit is achieved. -
Prevent the adjustment bolt of the pilot valve [p] from turning, while turning the locking nut clockwise until it touches the pilot valve spring cover. Tighten the locking nut carefully.
Operation Instructions
The 3-way controlled quick relief valve remains in quick relief mode only.
Troubleshooting
Symptom | Possible Causes | Check | Solution |
---|
Valve does not open
| 1. Release pressure set point is too high.| 1. Valve opens when adjusting bolt [p] turned
counterclockwise.
| 1. Adjust the release pressure set point.
2. Incorrect pilot valve
spring.
| 2. Published pilot valve
spring ranges.
| 2. Replace spring with
correct one.
3. Pilot valve [p] is clogged or stuck.| | 3. Turn off water supply to
the valve. Dismantle and clean the pilot valve
Valve dies not close
| 1. Water pressure is too
high.
| 1. Upstream water
pressure.
| 1. Check water supply
and/or consumers
2. Release pressure set point is too low.| 2. Valve closes as adjusting
bolt [p] is turned clockwise.
| 2. Adjust release pressure set point.
3. Blocked control filter [f].| 3. Very little flow from the inlet port when
the tube is disconnected downstream
of the filter
| 3. Turn off water supply to the valve, remove the filter and clean or
replace.
4. Foreign object trapped between valve seal and seat.| 4. The valve is
constantly discharging a small amount of water.| 4. Turn the adjusting bolt
[p] counterclockwise, until valve is fully open, for 5 seconds to flush the
object through the valve. Turn the adjusting bolt clockwise until valve fully
closed, and repeat set point adjustment.
If problem continues, turn off water supply to the valve. Remove the bonnet and diaphragm, remove the foreign object, and check that diaphragm, body and cover are not
damaged.
5. Diaphragm is damaged.| | 5. Replace diaphragm
Control Loop Drawings
www.irrigationglobal.com
t-R0 3 Way Quick Pressure Release Eliptix by Ari Aquestia online orders and
support
References
- Irrigationglobal.com Water Technologies Store. Irrigation, Filtration & Control
- R-20 Hydraulic Control Valves Agriculture and Water Supply Ooval ARI
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>