Introduction

Congratulations on your purchase of a Camelion Charger.
For Your Safety
To prevent damage to this unit or injury to yourself or to others, please read the following operating instructions before usage. Keep this operating instructions for your reference when needed.
This Charger has 4 channels for charging AAA, AA, C, D rechargea- ble batteries, and 2 channels for 9V rechargeable batteries. The build-in battery tester provides the battery status. Based on different battery capacity, the time of charging requirement can be selected.
When the pre-set time is reached, the charger will automatically switch to trickle charge from fast charge mode. It ensures that the damage of the rechargeable batteries caused by over-charging will be minimized.

Instruction:

  1. Insert the AC power supply cord into AC mains outletCamelion CM 9398 Universal Battery Charger - Introduction

  2. For Charging:
    – Set the timer according to the given charging timetable.
    – Set the function switch on the unit to “charge” position.
    – When AAA/AA/C/D types rechargeable batteries are inserted into the corresponding slot, the corresponding red LED will light up to indicate charging is in progress. If the charging battery is 9V cell, then the “9V” red LED will light up.
    – After the predetermined time, the charger will switch to the trickle charge mode and the green LED will light up. Please notice that there is no trickle for 9V battery, so the “9V” red LED will continue.
    – Remove the battery from the charger.
    Hot Tip
    To prevent overcharging note the appropriate charging time for your rechargeable battery and set the Time Control Feature accordingly.
    For example if you are inserting a Ni-MH 2500mAh battery which requires 12 hours charging, you can set the time first for 3 hours.
    When the red light switches off you can set it for an additional 9 hours.Camelion CM 9398 Universal Battery Charger - Introduction
1 Charge Times
    The rechargeable battery charge time depends on the nominal capacity. To determine the charge time for your batteries, divide the imprinted capacity by the charging current and multiply this value by 1.2. You can determine the charge time for e. g. a discharged Ni-MH rechargeable battery with 2300mAh: 2300:250 = 9.2 x 1.2 = 11.04 hours. Set the timer on 12 hours as mentionned under Hot Tip. For more information about charging times of our Camelion chargers, please visit our website http://vww.camelion.com/germ/chargingtabel.html

  3. For Testing:
    – Set the function switch on the unit to the “test” position.
    – Insert 1.2V rechargeable battery (AAA, AA, C or D cell) to the first slot close to function switch. The clear LED will light up.
    – Remember: You first determine if the battery is rechargeable by testing it. lf the clear LED glows weakly, the battery can be recharged.
    – When charging period is completed, if the battery does not brightly light the clear LED, discard it.
    Note: Only test 1.2V batteries (AAA/AA/C/D cells). Higher voltage batteries will burn out tester bulb.

  4. For Discharging:
    Switch the function switch on the unit to the ,,discharge“ position.
    (Please note that this charger cannot discharge 9V batteries) All the LEDs will go off to indicate batteries are in discharge mode.

  5. Please note that this is not an automatic charger. The charger does not switch to charge mode automatically after discharge. To check if the batteries are fully discharged, use the “test” feature.

Caution

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experiance and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Clean the charger with a clean dry cloth. Keeping the metal contacts clean will also help maintain performance.

  • If the LED status indicator does not light up make sure that the unit is properly plugged into the wall and the switch is set to the correct position. If the indicator still fails to light up or flashes the battery may be defective, improperly inserted or the presence of a short circuit.
    If a short circuit suspected please do not attempt to repair the unit yourself and bring the unit to an authorized Camelion repair center.

  • When charging different capacity/type batteries, the charging time should be calculated based on the charging times of similar capacity/type batteries. Refer to the appropriate charging table.

  • Correctly insert the batteries and avoid reversing the +/- polarities.

  • Cut of power after the batteries are fully charged.

  • The charger is intended for use with Ni-MH batteries only. Charging other battery may cause explosions, breakage, personal injury or property damage.

  • Incorrect use may result in electric shock.

  • For indoor use only. Keep away from humid and hot places, places to prevent short circuit or electric shock.

  • Do not disassemble or reassemble the charger. Never try to open or repair the rechargeable batteries.

  • Different batteries should not be mixed in different sizes or capacities.

  • If the external flexible cable is damaged, it shall be replaced by the manufacturer or his service agent or a similar person in order to avoid a hazard.

  • Do not use this charger with a damaged AC adapter, plug or socket outlet.

  • Batteries may contain hazardous materials, and may be non-disposable. Please contact the battery company for a proper disposable method.

Safety Instructions

In emergency cases, please unplug the electric socket and locate your nearest Camelion dealer.
Emergency cases are

  • Smoke from the unit
  • Liquid or material leakage
  • Changed shape
  • Dropped & broken casing or parts

Technical Specification:

Input Voltage: 240V AC 50Hz 9.6W
Output Voltage: 4 X 1.2V DC for AAA/AA/C/D cell; 2 X 9V DC for 9V cell
Size: CM9398GS (2A) 275 x 60 x 114 mm

Charge current| |
---|---|---
charge current| AAA/AA/C/D| 250mA
charge current| 9V| 13mA
trickle current| AAA/AA/C/D| 50mA
Charge Time table

Battery type| Ni-M H| charging time
AAA Micro/U M4| 900mAh| Set 6h
AA Mignon/UM3| 2500mAh| Set 24h
C Baby/UM2| 3500mAh| Set 24h
D Mono/UM1| 2500mAh| Set 24h
9V Block 006P| 200mAh| 20 h

This charge table includes only a small assortment of recharge- able batteries which could be used. For more information, please take a look at our Camelion website.