Product Information

  • Product Model: CH-1539TXPLPD
  • Product Name: 4K UHD+ HDMI/DisplayPort/VGA/USB Type-C to HDBaseT Switcher
  • Operation Manual: Included
  • Disclaimer: Please read the disclaimer section in the user manual
  • Copyright Notice: All products or service names mentioned in this document are trademarks of the companies with which they are associated.
  • Trademark Acknowledgments: Please refer to the trademark acknowledgments section in the user manual.
  • Safety Precautions: Please read all instructions before unpacking, installing, or operating this equipment. Also, read the safety precautions section in the user manual.
  • Version History: The current version is RDV1, released on 2019/04/19 as a preliminary release.

DISCLAIMERS
The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document. Cypress Technology reserves the right to make improvements to this document and/or product at any time and without notice.

COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or any of its part translated into any language or computer file, in any form or by any means—electronic, mechanical, magnetic, optical, chemical, manual, or otherwise—without express written permission and consent from Cypress Technology. © Copyright 2018 by Cypress Technology. All Rights Reserved.

TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document are trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS

Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment:

  • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
  • To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
  • Never spill liquid of any kind on or into this product.
  • Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit.
  • Do not attach the power supply cabling to building surfaces.
  • Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged.
  • Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it.
  • To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit.
  • Please completely disconnect the power when the unit is not in use to avoid wasting electricity.

VERSION HISTORY

REV. DATE SUMMARY OF CHANGE
RDV1 2019/04/19 Preliminary release

INTRODUCTION

This 4×1 Multi-Format to HDBaseT Switch is a 4K@60Hz (4:4:4) switcher featuring HDMI, DisplayPort, USB Type-C, and VGA with stereo inputs which are automatically converted to the standard HDBaseT format for
use with a compatible receiver. The HDMI, DisplayPort and USB-C inputs support resolutions up to 4K@60Hz (4:4:4, 8-bit) and the VGA input supports resolutions up to WUXGA (RB). With the use of the 3.5mm audio input, stereo audio can be embedded with the VGA source as well. Despite HDBaseT’s 10.2Gbps bandwidth limitation, high bandwidth 4K UHD HDMI video sources, up to and including 4K@60Hz (4:4:4, 8-bit), can be supported and will be automatically converted to 1080p when necessary.
Signal management features such as automatic switching based on input signal and hot plug detection enable convenient hands-free operation. Additional functionality such as EDID management, HDCP management and basic signal event automation (which can send customized CEC commands to the display automatically) is also available. The USB Type-C input can provide power (up to 60W) to any connected device and the HDBaseT output provides PoH (Power over HDBaseT) to power compatible receivers, providing greater flexibility in installations. Control is provided via a front panel button, WebGUI, Telnet, and RS-232.

APPLICATIONS

  • Household entertainment sharing and control
  • Lecture room display and control
  • Showroom display and control
  • Meeting room presentation and control
  • Classroom display and control

PACKAGE CONTENTS

  • 1×HDMI/DisplayPort/VGA/USB Type-C to HDBaseT Switcher
  • 1×24V/3.75A DC Power Adapter
  • 1×Power Cord
  • 1×3.5mm to IR Blaster Cable
  • 1×3-pin Terminal Block
  • 1×Operation Manual

SYSTEM REQUIREMENTS

  • Source equipment such as media players, video game consoles, PCs, or set-top boxes.
  • A compatible HDBaseT receiver with PoH (PD) support is recommended.
  • The use of Premium High Speed HDMI cables, and industry standard Cat.6, Cat.6a or Cat.7, is highly recommended.

FEATURES

  • HDMI 2.0, DisplayPort 1.4, and DVI 1.0 compliant
  • HDCP 1.x and 2.2 compliant
  • Switchable HDMI, DisplayPort, VGA with analog audio, and USB Type-C inputs
  • 1 HDBaseT output
  • Digital inputs support up to 4K UHD (18Gbps, 4K@60Hz 4:4:4, 8-bit)
  • VGA input supports resolutions up to WUXGA (RB)
  • Analog stereo audio is automatically embedded with the video from the VGA input
  • HDBaseT output supports resolutions up to 4K@60Hz (4:2:0, 8-bit) or 4K@30Hz (4:4:4, 8-bit). 4K@50/60Hz (4:4:4, 8-bit) or 4K@any (10/12-bit) sources will be automatically converted to 1080p.
  • Supported HDBaseT feature set: HD Video & Audio, PoH, and Control Extension (Bi-directional IR/RS-232)
  • HDBaseT output transmits video, audio and data over a single Cat.5e/6/7 cable and can reach distances up to 40m/131ft at 4K when using Cat.6a/7
  • Supports pass-through of many audio formats including 8 channel LPCM, Bitstream, and HD Bitstream
  • Supports standard PoH from the unit to connected HDBaseT Receivers (compatible Receivers only)
  • Supports manual input selection or automatic input selection with hot plug detection and “Last Memory” feature
  • Basic signal event automation using CEC commands
  • Comprehensive EDID management
  • USB Type-C port provides up to 60W to power or charge the connected device
  • Controllable via a front panel button, WebGUI, Telnet, and RS-232

OPERATION CONTROLS AND FUNCTIONS

Front Panel

  1. SERV. Port: This port is reserved for firmware update use only.
  2. CONTROL Port: Connect directly, or through a network switch, to your PC/laptop to control the unit via Telnet/WebGUI.
  3. POWER LED: This LED will illuminate to indicate the unit is on and receiving power.
  4. SELECT Button & VGA/USB-C/HDMI/DP LEDs: Press the Select button to sequentially switch through the available inputs. The currently selected input’s LED will illuminate green. The LEDs will illuminate red to indicate inputs that have live sources but are not currently selected.

Rear Panel

  1. VGA IN Port: Connect to VGA source equipment such as a PC or laptop.
    AUDIO IN Port: Connect to the stereo analog output of the device connected to the VGA input port.

  2. USB-C IN Port: Connect to USB Type-C video source equipment such as a PC or laptop.
    Note: Not all devices with USB Type-C ports can support video output. Please verify that the device supports video output from the USB Type-C port before connecting it.

  3. HDMI IN Port: Connect to HDMI source equipment such as a media player, game console, or set-top box.

  4. DP IN Port: Connect to DisplayPort source equipment such as a PC or laptop.

  5. CAT.5e/6/7 OUT Port: Connect to a compatible HDBaseT Receiver with a single Cat.5e/6/7 cable for transmission of all data signals. PoH will also be supplied to a connected compatible PD Receiver.

  6. IR EXTENDER Port: Connect to an IR Extender to receive IR control signals and extend them to devices connected to the other end of the HDBaseT connection. Ensure that the remote being used is within direct line-of-sight of the IR Extender.

  7. IR BLASTER Port: Connect to the provided IR Blaster to transmit IR signals from the other end of the HDBaseT connection to devices within direct line-of-sight of the IR Blaster.

  8. RS-232 CONSOLE Port: Connect directly to a PC, laptop, or other serial control device with a 3-pin adapter cable to send RS-232 commands to control the unit.
    RS-232 BYPASS Port: Connect to a PC, laptop, or other serial control device with a 3-pin adapter cable for the extension of RS-232 signals to the Receiver.

  9. DC 24V Port: Plug the 24V DC power adapter into this port and connect it to an AC wall outlet for power.

IR Cable Pinouts

IR Cable Pinouts IR Blaster Cable

Serial Port Default Settings

Baud Rate| 19200
Data Bits| 8
Parity Bits| None
Stop Bits| 1
Flow Control| None

WebGUI Control

  • Device Discovery
    Please obtain the “Device Discovery” software from your authorized dealer and save it in a directory where you can easily find it. Connect the unit and your PC/Laptop to the same active network and execute the “Device Discovery” software. Click on “Find Devices on Network” and a list of devices connected to the local network will show up indicating their current IP address.
    Note: The unit’s default IP address is 192.168.1.50.
    By clicking on one of the listed devices you will be presented with the network details of that particular device.
1.  **IP Mode:** If you choose, you can alter the static IP network settings for the device, or switch the unit into DHCP mode to automatically obtain proper network settings from a local DHCP server. To switch to DHCP mode, please select DHCP from the IP mode drop-down, then click “Save” followed by “Reboot”.
2.  **WebGUI Hotkey:** Once you are satisfied with the network settings, you may use them to connect via Telnet or WebGUI. The network information window provides a convenient link to launch the WebGUI directly.
  • WebGUI Overview
    After connecting to the WebGUI’s address in a web browser, the login screen will appear. Please enter the appropriate user name and password then click “Submit” to log in.
    Note: The default user name and password is “admin”.
    On the left side of the browser you will see the following menu tabs where all primary functions of the unit are controllable via the built in WebGUI. The individual functions will be introduced in the following sections.
    Clicking the red “Logout” tab will automatically log the currently connected user out of the WebGUI and return to login page.
  1. Switch Tab
    This tab provides A/V routing control, HDCP management, auto switch control, A/V mask, and I/O renaming options. To assign a new A/V route, please click the Output button on the left and then click on the button of the preferred input port on the right. As each button is selected they will become highlighted. The new route will become active immediately and the routing information displayed on the buttons will change accordingly.

  2. Output: This button selects the output to route A/V Inputs to. Details about the output name and currently selected Input are also displayed here. Clicking on the “Edit” icon ( ) opens up the Output Edit window. Clicking on the “A/V Mask” icon ( ) will mute or unmute the audio and video output.

  3. Auto: Auto switching may be enabled or disabled by clicking on the On/Off slider to toggle the setting.

  4. Input VGA/USB-C/HDMI/DP: Buttons for selecting the input (VGA, USB Type-C, HDMI, or DisplayPort) to route to the output. Details about the input names and current sync/HDCP status are also displayed here. Clicking on the “Edit” icon ( ) opens up the Input Edit window.

  5. Output Edit: Provides control over the name of the output.

  *  **Set Output Name:** To rename the output, type the new name in the space provided in the Edit window. The name can be up to 8 characters long. Click the “Save Change” button to confirm the change.
5.  **Input Edit:** Provides Individual control over the name of each input and the behavior of HDCP on that input.
  *  **Set Input Name:** To rename an input, type the new name in the space provided in the Edit window. The name can be up to 8 characters long. Click the “Save Change” button to confirm the change.
  *  **HDCP:** The HDCP mode of each input can be set to “Follow Source”, “Follow Display”, or “Disabled”. Changes made to this setting occur immediately.  

Note: The VGA input cannot support HDCP.

  1. Automation Tab
    The Automation tab provides control over the unit’s automatic control command broadcast behavior when any of the specified Automation Events occur. Automation commands are sent to the connected display device via standard CEC.

    • Event: Use the dropdown to select the Automation Event to configure. Available Automation Events are:

    • Power On: This unit is powered on.

    • Out A Source Active: The currently selected input changes from inactive to active.

    • Out A Source Lost: The currently selected input changes from active to inactive.

    • CEC: Enable or disable sending a CEC command when the currently selected Automation Event is activated.
      Note: CEC support must also be enabled on the connected HDMI display device.

    • Delay: Set the length of time, in seconds, that the specified Automation Event must continue to be true before sending the defined command.

    • Wait: Set the length of time, in seconds, to wait after this Automation Event has been activated before ANY new Automation Event can be detected.

    • CEC Command: Shows the CEC command, in ASCII hex pairs, that will be sent when the specified Automation Event is activated. Click the “Edit” button to modify the command. Click the “Test” button to send the command immediately.

  2. EDID Tab
    This tab provides the option of six standard EDIDs, four customer uploaded User EDIDs, and one sink sourced EDID that can be assigned to any or all of the applicable input ports. The contents of any of these EDIDs may also be downloaded from here.

  3. User EDID

  *  **Upload:** To upload a User EDID, select the User EDID slot to upload into from the dropdown list and then click the “Upload” button. An EDID Upload window will appear, allowing you to locate and upload the preferred EDID file (*.bin format) from a local PC. Once the correct file has been selected, please click the “Upload” button in the window, and the file will be transferred to the unit.
  *  **Download:** To save an existing User EDID to your local PC, select the User EDID slot from the dropdown list and then press the  

“Download” button. Depending on your browser settings you will either be asked where to save the downloaded file, or the file will be transferred to the default download location on your PC.

  *  **Edit Name:** Click the “Edit Name” button to open a window that allows changing the name of the User EDID. Click the “Save Change” button within the window to confirm the change.
2.  **Output EDID**
  *  **Download:** To save an EDID provided by the connected HDBaseT Receiver to your local PC, select the output from the dropdown  

list then press the “Download” button. Depending on your browser settings you will either be asked where to save the downloaded file, or the file will be transferred to the default download location on your PC.

3.  **Input EDID**
  *  **Appoint/All:** The Input EDID section allows for the assignment of an EDID to each individual input port, or to all inputs at once. Click the selection bar to toggle between “Appoint” (individual assignment), or “All” inputs.
  *  **EDID Selection:** Click on one or more input buttons to open the EDID Table List window. Select the new EDID source to use, from the choices on the right, and the change will occur immediately across all selected Inputs.

This unit provides the following 6 default EDIDs:

EDID NAME EDID CONTENT
1080P@60/PCM/2CH 1920×1080p@60Hz (148MHz), 8-bit color, LPCM 2.0
1080P@60/PCM/Bitstream/ MCH 1920×1080p@60Hz (148MHz), 8-bit color,

LPCM 7.1 & Bitstream
4K@30/PCM/2CH| 3840×2160p@30Hz (297MHz), Deep Color (8/10/12-bit), LPCM 2.0
4K@30/PCM/Bitstream/MCH| 3840×2160p@30Hz (297MHz), Deep Color (8/10/12-bit), LPCM 7.1 & Bitstream
4K@60/PCM/MCH| 3840×2160p@60Hz (594MHz), Deep Color (8/10/12-bit), LPCM 2.0
4K@60/PCM/Bitstream/MCH| 3840×2160p@60Hz (594MHz), Deep Color (8/10/12-bit), LPCM 7.1 & Bitstream

Note: In most cases, assigning a new EDID to an input will cause the affected input to briefly blink out while the source adapts to the new information.

Network Tab
This tab provides network configuration options including changing the IP mode, viewing/setting the IP configuration, changing the admin login password, and changing the Web Login timeout.

  1. IP Configuration: IP Mode may be switched between Static IP or DHCP. In Static IP Mode the IP, netmask and gateway addresses may be manually set. When in DHCP Mode, the unit will attempt to connect to a local DHCP server and obtain IP, netmask and gateway addresses automatically. Please press “Save” after making any changes to the IP configuration or mode.
    Note: If the IP address is changed then the IP address required for WebGUI/Telnet access will also change accordingly.

  2. Web Login Account: The WebGUI admin password can be changed here. Please press “Save” after entering the old and new passwords to enact the change.
    Note: The default password is “admin”.

  3. Web Login Timeout: Select the length of time to wait before logging the user out of the WebGUI due to inactivity. Available range is from 0 to 35970 minutes. Setting it to 0 will disable the timeout function.

System Tab
This tab provides serial number information, system configuration backup/restore/reset, system reboot, and firmware update functions.

  1. System Configuration
    • Download: The current system configuration, including routing and settings, may be saved as an XML file to a PC. Click the “Download” button to save the current system configuration to your local PC.
    • Restore: Previously saved system configurations may be restored from a saved XML file. Click the “Choose File” button to locate the saved XML file, then click the “Restore” button to upload and activate the selected configuration.
  2. Factory Reset: Press the “ALL Reset” button to reset the unit to its factory default state. After the reset is complete, the unit will reboot automatically.
  3. System Reboot: Click this button to reboot the unit.
  4. Firmware Upgrade: To update the unit’s firmware, click the “Choose File” button to open the file selection window and then select the firmware update file (*.bin format) located on your local PC. After selecting the file, click the “Upgrade” button to begin the firmware update process. After the upgrade is complete, the unit will reboot automatically.
  5. Serial Number: Displays the unit’s serial number.

Telnet Control
Before attempting to use Telnet control, please ensure that both the unit and the PC are connected to the same active networks.

Once in the Command Line Interface (CLI) type “telnet” followed by the IP address of the unit (and the port number if it is non-standard) and then hit “Enter”. This will connect us to the unit we wish to control. Microsoft Windows [Version 6.1.7601] Copyright (c) 2009 Microsoft Corporation. All rights reserved.
C:\Users\Adminstrator\telnet 192.168.1.50 23
Note 1: If the IP address is changed then the IP address required for Telnet access will also change accordingly.
Note 2: The default IP address is 192.168.1.50.

RS-232 and Telnet Commands

COMMAND DESCRIPTION AND PARAMETERS
? Show the full command list.
help Show the full command list.
set factory default Reset the unit to the factory defaults.
set system reboot Reboot the unit.
get fw ver Show the unit’s current firmware version.
set in N1 name N2 Set the name of the specified input.

N1 = 1 ~ 4                 [Input port]

N2 = {Name}            [8 characters max]

get in N1 name| Show the current name of the specified input.

N1 = 1 ~ 4                 [Input port]

get in name list| List the names of all inputs on the unit.
set out A name N1| Set the name of the output.

N1 = {Name}            [8 characters max]

get out A name| Show the current name of the output.
set out A route N1| Route the specified input to the output.

N1 = 1 ~ 4                 [Input port]

get out A route| Show the current input routed to the output.
set out A mask N1| Enable or disable the A/V Mask setting on the

output.

Available values for N1 :

ON                             [Output muted]

OFF                            [Normal output]

get out A mask| Display the current A/V Mask setting for the

output.

COMMAND DESCRIPTION AND PARAMETERS
set in N1 hdcp mode N2 Set the HDCP behavior of the specified input.

N1 = 1~4                   [Input port] Available values for N2 :

0                                                  [Disabled]

1                                                  [Follow source]

2                                                  [Follow display]

get in N1 hdcp mode| Show the current HDCP behavior used by the

specified input.

N1 = 1~4                   [Input port]

set all in edid mode N1| Select the EDID management mode to use (All or Appoint) for all inputs.

Available values for N1 :

ON                             [All mode]

OFF                            [Appoint mode]

get all in edid mode| Show the current EDID management mode

used by all inputs.

COMMAND DESCRIPTION AND PARAMETERS
set all in edid N1 Set the EDID to use when the “All” EDID

mode is active. Available values for N1 :

1                                 [1080P, 2CH]

2                                 [1080P, MCH]

3                                 [4K@30, 2CH]

4                                 [4K@30, MCH]

5                                 [4K@60, 2CH]

6                                 [4K@60, MCH]

7                                                  [User EDID 1]

8                                                  [User EDID 2]

9                                                  [User EDID 3]

10                                               [User EDID 4]

11                                               [Sink EDID]

get all in edid| Show the current EDID used by the “All”

EDID mode.

COMMAND DESCRIPTION AND PARAMETERS
set in N1 edid N2 Set the EDID to use on the specified input.

N1 = 1~4                   [Input port] Available values for N2 :

1                                 [1080P, 2CH]

2                                 [1080P, MCH]

3                                 [4K@30, 2CH]

4                                 [4K@30, MCH]

5                                 [4K@60, 2CH]

6                                 [4K@60, MCH]

7                                                  [User EDID 1]

8                                                  [User EDID 2]

9                                                  [User EDID 3]

10                                               [User EDID 4]

11                                               [Sink EDID]

get in N1 edid| Show the EDID currently being used on the

specified input.

N1 = 1~4                   [Input port]

get in edid list| List all available EDID selections.
set edid N1 name N2| Set the name for the specified EDID.

Available values for N1 :

7                                                  [User EDID 1]

8                                                  [User EDID 2]

9                                                  [User EDID 3]

10                                               [User EDID 4]

N2 = {Name}            [16 characters max]

Note: Only User EDIDs may be renamed

COMMAND DESCRIPTION AND PARAMETERS
get edid N1 name Show the current name of the specified EDID.

Available values for N1 :

7                                                  [User EDID 1]

8                                                  [User EDID 2]

9                                                  [User EDID 3]

10                                               [User EDID 4]

set user N1 edid data N2| Upload a new EDID (in HEX format) for use

as the specified User EDID.

N1 = 1 ~ 4                 [User EDID]

N2 = {EDID data}    [Comma delimited

hex pairs]

get user N1 edid data| Show the current contents of the specified

User EDID as HEX data.

N1 = 1 ~ 4                 [User EDID]

set out auto mode N1| Set the auto switching behavior of the unit. Available values for N1 :

0                                                  [Disabled]

1                                                  [Auto switch]

get out auto mode| Show the current auto switching mode of the

unit.

get ipconfig| Show the unit’s current IP configuration

information.

set ip mode N1| Set the IP address assignment mode. Available values for N1 :

0                                                  [Static IP mode]

1                                                  [DHCP mode]

get ip mode| Show the current IP address assignment

mode.

COMMAND DESCRIPTION AND PARAMETERS
set ipaddr N1 Set the unit’s static IP address.

N1 = X.X.X.X            [X = 0 ~ 255]

get ipaddr| Show the unit’s current IP address.
set netmask N1| Set the unit’s static netmask.

N1 = X.X.X.X            [X = 0 ~ 255]

get netmask| Show the unit’s current netmask.
set gateway N1| Set the unit’s static gateway address.

N1 = X.X.X.X            [X = 0 ~ 255]

get gateway| Show the unit’s current gateway address.
set webgui password N1| Set the WebGUI login password.

N1 = {Password}     [16 characters max]

get webgui password| Show the current WebGUI login password.
set webgui login timeout N1| Set the WebGUI inactivity timeout value. Available values for N1 :

0                                                  [No timeout]

1  ~ 35970                 [Timeout in minutes]

get webgui login timeout| Show the current WebGUI inactivity timeout

value.

set webgui port N1| Set the unit’s WebGUI access port.

N1 = 1 ~ 65535       [TCP port]

get webgui port| Show the unit’s current WebGUI access port.
set telnet port N1| Set the unit’s Telnet access port.

N1 = 1 ~ 65535       [TCP port]

get telnet port| Show the unit’s current Telnet access port.
COMMAND| DESCRIPTION AND PARAMETERS
---|---
set automation event N1 cec A N2| Enable or disable the specified Automation

Event’s CEC response. Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source

active]

3                                                  [Out A source lost] Available values for N2 :

ON                             [Event enabled]

OFF                            [Event disabled]

get automation event N1 cec A| Show the current state of the specified

Automation Event’s CEC response. Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

set automation event N1 cec A delay N2| Set the delay time that the specified Automation Event must continue to be true before sending the defined CEC command.

Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

N2 = 0 ~ 240            [Delay time in seconds]

COMMAND DESCRIPTION AND PARAMETERS
get automation event N1 cec A delay Show the delay time for the

specified

Automation Event’s CEC response. Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

set automation event N1 cec A wait N2| Set the length of time to wait after an Automation Event’s CEC response has been activated before ANY other Automation Event can be detected.

Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

N2 = 0 ~ 240            [Wait time in seconds]

get automation event N1 cec A wait| Show the wait time for the specified

Automation Event’s CEC response. Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

COMMAND DESCRIPTION AND PARAMETERS
set automation event N1 cec A command N2 Set the CEC command to send

when the

specified Automation Event is activated.

Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

N2 = {CEC data}      [Comma delimited hex

pairs]

get automation event N1 cec A command| Show the CEC command to be sent when the

specified Automation Event is activated.

Available values for N1 :

1                                                  [Power on]

2                                                  [Out A source active]

3                                                  [Out A source lost]

Note: Commands will not be executed unless followed by a carriage return. Commands are not case-sensitive.

CONNECTION DIAGRAM

SPECIFICATIONS

Technical Specifications

  • HDMI/DisplayPort/USB-C Bandwidth 18Gbps

  • VGA Bandwidth 153MHz

  • HDBaseT Bandwidth 10.2Gbps

  • Input Ports

    • 1×HDMI (Type-A)
    • 1×DisplayPort
    • 1×USB (Type-C)
    • 1×VGA (HD-15)
    • 1×Stereo Audio (3.5mm)
  • Output Port 1×HDBaseT (RJ-45)

  • Pass-through Ports

    • 1×IR Extender (3.5mm)
      1×IR Blaster (3.5mm)
      1×RS-232 (3-pin Terminal Block)
  • Control Ports

    • 1×RS-232 (3-pin Terminal Block)
      1×Ethernet (RJ-45)
  • Service Port 1×USB 2.0 (Type A)
    IR Frequency

    • 30 – 50kHz
    • (30 – 60kHz under ideal conditions)
  • Baud Rate Up to 115200

  • Power Supply 24V/3.75A DC (US/EU standards, CE/FCC/UL certified)

  • ESD Protection (HBM)

    • ±8kV (Air Discharge)
    • ±4kV (Contact Discharge)
  • Dimensions (W×H×D)

    • 231.5mm×25mm×108mm [Case Only] 231.5mm×25mm×116mm [All Inclusive]
  • Weight 657g

  • Chassis Material Metal (Steel)

  • Chassis Color Black

  • Operating Temperature 0˚C – 40˚C/32˚F – 104˚F

  • Storage Temperature -20˚C – 60˚C/-4˚F – 140˚F

  • Relative Humidity 20 – 90% RH (Non-condensing)

  • Power Consumption 82W

Video Specifications
Note: Supported input resolutions with data rates higher than 10.2Gbps will be automatically scaled down to 1080p at the same refresh rate to fit within the 10.2Gbps transmission limit of HDBaseT.

Supported Resolutions (Hz)     In   Out
HDMI DP USBC VGA HDBT
720×400p@70/85 × 70
640×480p@60/72/75/85
720×480i@60 × × ×
720×480p@60 ×
720×576i@50 × × ×
720×576p@50 ×
800×600p@56/60/72/75/85
848×480p@60 × ×
1024×768p@60/70/75/85
1152×864p@75
1280×720p@50/60 ×
1280×768p@60/75/85
1280×800p@60/75/85 60
1280×960p@60/85
1280×1024p@60/75/85
1360×768p@60
1366×768p@60
1400×1050p@60 × × ×
1440×900p@60/75
1600×900p@60RB ×
Supported Resolutions (Hz)     In   Out
--- --- --- --- --- ---
HDMI DP USBC VGA HDBT
1600×1200p@60 × ×
1680×1050p@60
1920×1080i@50/60 ×
1920×1080p@24/25/30 ×
1920×1080p@50/60
1920×1200p@60RB × ×
2048×1080p@24/25/30 × × ×
2048×1080p@50/60 × × ×
2560×1440p@60RB × × × ×
2560×1600p@60RB × × × ×
3840×2160p@24/25/30 ×
3840×2160p@50/60 (4:2:0) ×
3840×2160p@24, HDR10 × ×
3840×2160p@50/60 (4:2:0), HDR10 × ×
3840×2160p@50/60 × ×
4096×2160p@24/25/30 ×
4096×2160p@50/60 (4:2:0) ×
4096×2160p@24, HDR10 × ×
4096×2160p@50/60 (4:2:0), HDR10 × ×
4096×2160p@50/60 × ×

Audio Specifications

  1. Digital Audio**
    HDMI/DisplayPort/USB-C Input**

    LPCM
    Max Channels| 8 Channels
    Sampling Rate (kHz)| 32, 44.1, 48, 88.2, 96, 176.4, 192
    Bitstream
    Supported Formats| Standard & High-Definition
    HDBaseT Output

    LPCM
    Max Channels| 8 Channels
    Sampling Rate (kHz)| 32, 44.1, 48, 88.2, 96, 176.4, 192
    Bitstream
    Supported Formats| Standard & High-Definition

  2. Analog Audio**
    Analog Input**

    Max Audio Level| 2Vrms
    Impedance| 36.9kΩ
    Type| Unbalanced

Cable Specifications



Cable Length

| 1080p| 4K30| 4K60
---|---|---|---


8- bit

| ****

12- bit

| (4:4:4)

8- bit

| (4:4:4)

8- bit

High Speed HDMI Cable
HDMI Input| 15m| 10m| 5m| 3m
DisplayPort Cable
DisplayPort Input| 15m| 10m| 2m| 2m
USB-C Cable
USB-C Input| 2m
VGA Cable
VGA Input| 2m| ×
Ethernet Cable
Cat.5e/6| 60m| 35m
Cat.6a/7| 70m| 40m

  • Bandwidth Category Examples:
    • 1080p (FHD Video)
    • Up to 1080p@60Hz, 12-bit color
    • Data rates lower than 5.3Gbps or below 225MHz TMDS clock
    • 4K30 (UHD Video)
    • 4K@24/25/30Hz & 4K@50/60Hz (4:2:0), 8-bit color
    • Data rates higher than 5.3Gbps or above 225MHz TMDS clock but below 10.2Gbps
    • 4K60 (UHD+ Video)
    • 4K@50/60Hz (4:4:4, 8-bit), conversion to 1080p will be performed when output over HDBaseT
    • 4K@50/60Hz (4:2:0, 10-bit HDR), conversion to 1080p will be performed when output over HDBaseT
    • Data rates higher than 10.2Gbps

HDBaseT Features

HDBaseT Feature Set Transmitter
Video & Audio Supported
LAN Extension Unsupported
Send power to Receiver Supported (PoH)
Accept power from Receiver Unsupported
IR Extension Supported
RS-232 Extension Supported
USB 2.0 Extension Unsupported

ACRONYMS

ACRONYM COMPLETE TERM
ADC Analog-to-Digital Converter
ASCII American Standard Code for Information Interchange
AV Audio/Video
AVR Audio/Video Receiver or Recorder
Cat.5e Enhanced Category 5 cable
Cat.6 Category 6 cable
Cat.6a Augmented Category 6 cable
Cat.7 Category 7 cable
CEC Consumer Electronics Control
CLI Command-Line Interface
DHCP Dynamic Host Configuration Protocol
DP DisplayPort
DVI Digital Visual Interface
EDID Extended Display Identification Data
GUI Graphical User Interface
HD High-Definition
HDBT HDBaseT
HDCP High-bandwidth Digital Content Protection
HDMI High-Definition Multimedia Interface
HDR High Dynamic Range
HDTV High-Definition Television
IP Internet Protocol
IR Infrared
LAN Local Area Network
LED Light-Emitting Diode
LPCM Linear Pulse-Code Modulation
MAC Media Access Control
PC Personal Computer
ACRONYM COMPLETE TERM
--- ---
PD Powered Device
PoH Power over HDBaseT
PSE Power Sourcing Equipment
SNR Signal-to-Noise Ratio
TCP Transmission Control Protocol
UHD Ultra-High-Definition
UHD + Ultra-High-Definition Plus
USB Universal Serial Bus
VGA Video Graphics Array
WUXGA (RB) Widescreen Ultra Extended Graphics Array (Reduced

Blanking)

XGA| Extended Graphics Array

CYPRESS TECHNOLOGY CO., LTD.
www.cypress.com.tw

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CYP User Manuals

Related Manuals