HILTI CFS-CID 50 Firestop Cast In Device Instruction Manual

June 13, 2024
HILTI

HILTI CFS-CID 50 Firestop Cast In Device

Product Information

The Firestop Cast-in Device CFS-CID is a product designed to provide firestop protection for pipe penetrations in concrete structures. It is suitable for various applications and offers several advantages.

Applications:

  • Wastewater
  • Roof drainage
  • Drinking water
  • Heating

Advantages:

  • Easy installation
  • Provides firestop protection
  • Compatible with various pipe materials
  • Allows for rigid floor partitioning

Technical Data:

  • Base materials: Concrete
  • Height: 250 mm
  • Color: Red
  • Re-penetration Reaction to fire class (EN 13501-1): Easy E

Approvals:
The Firestop Cast-in Device CFS-CID has been approved according to EN 13501-2: 2007+A1:2009 and EN 1366-3:2009 standards.

Ordering Information

Item Number Description Sales Pack Quantity
2124523 CFS-CID 50 1 pc
2124524 CFS-CID 75 1 pc
2124525 CFS-CID 110 1 pc
2124526 CFS-CID 160 1 pc

Product Usage Instructions

Follow the instructions below to properly use the Firestop Cast-in Device CFS- CID:

  1. Ensure that the base material is concrete.
  2. Determine the appropriate height of the device based on your specific requirements.
  3. Select the correct item number and description for your desired diameter (50, 75, 110, or 160).
  4. Order the device with the corresponding item number.
  5. Upon receiving the device, carefully unpack it and inspect for any damage.
  6. If using the CFS-CID Manifold Adapter, order it separately with item number 2124527.
  7. If additional height extension is required, order the Extension Tubes with the appropriate item number (244252, 244253, 244254, or 244255).
  8. Install the Firestop Cast-in Device CFS-CID according to the guidelines provided in the ETA-20/1233 document.
  9. Ensure proper fixing to the formwork using wood nails.
  10. Do not backfill the gap between the device and the pipe.
  11. For pipe penetrations, refer to the approved applications and select the appropriate pipe material.
  12. Follow the classification in rigid floor for the specific pipe material and thickness.

For any other approved applications or specific instructions, refer to the complete ETA-20/1233 document.

FIRESTOP CAST-IN DEVICE CFS-CID

Applications

  • Concrete slabs built with traditional formwork
  • New building construction
  • Sealing combustible and non-combustible pipe penetrations
  • Tested with pipe elbows, which allows reduced service zone

Advantages

  • One-step firestop solution for a variety of pipe materials and diameters – no additional backfilling required
  • Modular connection allows close placement of multiple penetrations
  • Quicker and simpler installation
  • Integrated moisture and smoke seal
  • Lid strong enough to carry foot traffic and light access equipment

Technical Data

  • Base materials Concrete
  • Approvals EN 13501-2: 2007+A1:2009, EN 1366-3:2009
  • Height 250 mm
  • Application temperature range –5 – 50 °C
  • Temperature resistance range –20 – 100 °C
  • Color Red
  • Re-penetration Easy
  • Reaction to fire class (EN 13501-1) E
Ordering description Pipe diameter – range Sales pack quantity Item number
CFS-CID 50 40 – 63 mm 1 pc 2124523
CFS-CID 75 50 – 75 mm 1 pc 2124524
CFS-CID 110 80 – 110 mm 1 pc 2124525
CFS-CID 160 125 – 160 mm 1 pc 2124526

MANIFOLD ADAPTER CFS-CID

Applications

  • Creation of a 70 mm deep recess in a slab
  • For use in conjunction with the appropriate cast-in device
  • Creates an underside void for the installation of an elbow connector system

Advantages

  • Allows a manifold to be accommodated and thus simplifies plumbing installations
  • Accommodates manifold connections and shower traps for walk-in showers and wet rooms
  • Reduces final ceiling depth by creating a 70 mm recess in the slab
  • Pipes can be installed closer to the ceiling, thus reducing spacing

Technical Data

  • Base materials Concrete
  • Height 77 mm
  • Application temperature range –5 – 50 °C
  • Color Red

HEIGHT EXTENSIONS CFS-CID

Applications

  • For use with CFS-CID cast-in devices

Advantages

  • The “Screw-on” feature promotes a secure connection to the device and cover cap
  • Adds 150 mm of height to pre-formed firestop devices

Technical Data

  • Base materials Concrete
  • Height 150 mm
  • Application temperature range –5 – 50 °C
  • Color Red
Ordering description Pipe diameter – range Sales pack quantity Item number
Extension tube 6″ CP 680-P 2″ 40 – 63 mm 1 pc 244252
Extension tube 6″ CP 680-P 3″ 50 – 75 mm 1 pc 244253
Extension tube 6″ CP 680-P 4″ 90 – 110 mm 1 pc 244254
Extension tube 6″ CP 680-P 6″ 125 – 160 mm 1 pc 244255

GENERAL INSTRUCTIONS FOR USE

GENERAL INFORMATION

MAIN APPROVED APPLICATIONS

  • Coes “Blue Power”, Coes “PhoNoFire”, “Geberit Silent PP”, Marley Silent, Ostendorf “Skolan-dB”, Pipelife “Master 3”, POLOPLAST “Polokal NG”, POLOPLAST
    “Polokal 3S”, “POLOPLAST Polokal XS”, Rehau “Raupiano Plus”, Wavin “AS”, KeKelit “Phonex AS”, Wavin “SiTech”, Valsire “Triplus”, Valsire “Silere”
    Excerpt of ETA document. Check the exact field of application for each pipe (type, diameter and pipe wall thickness) in the ETA-20/1233 document.

OTHER APPROVED APPLICATIONS

CHARACTERISTICS OF CFS-CID

Hilti Corporation
9494 Schaan, Liechtenstein
P +423-234 2965
www.facebook.com / hiltigroup
www.hilti.group
Hilti = registered trademark of Hilti Corp., Schaan W4561 1021 0-en 2 Printed in Liechtenstein © 2021 Right of technical and program changes reserved S. E. & O.