systemair EZ106N Radiant Heater Instruction Manual
- June 13, 2024
- systemair
Table of Contents
- EZ106N Radiant Heater
- Accessories
- Controls
- Wiring diagrams
- General Instructions
- Application
- Operation
- Mounting
- Electrical installation
- Control
- Start-up
- Maintenance
- Residual current circuit breaker
- Packaging
- Handling of product at end of working life
- Safety
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Original instructions
Elztrip EZ100
EZ106N Radiant Heater
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not
apply to all application areas.
The Regulation applies when an installation is intended to provide thermal
comfort for people in the premises. The Regulation does not apply to heating
installations of a more technical nature e.g. in engineering/utility rooms, in
production processes, frost protection, etc. The Regulation also does not
apply to installations in vehicles, offshore or outdoors.
Many of Frico’s products can be used as both local space heaters (as defined
in (EU) 2015/1188) and for technical heating purposes. It is up to the
installer responsible for the installation to assess whether the Ecodesign
Regulation is applicable or not. Control solutions for installations not
covered by the Ecodesign Regulation are listed in a separate table.
| L [mm]| A [mm]
---|---|---
EZ106N| 870| 655
EZ111N| 1470| 1252
EZ115N| 1950| 1731
| EZ100 [mm]
---|---
A| 50
B| 50
C| 50
D| 500
E| 1800
Accessories
Item number| Type|
---|---|---
10004| EZMVK| (2x)
Controls
Item number | Type | HxWxD [mm] |
---|---|---|
92790 | TAP16R | 87x87x53 |
205540 | TEP44 | 87x87x55 |
93044 | RTX54 | 82x88x25 |
205550 | SKG30 | 115x85x40 |
211780 | PDK65 | 102x70x50 |
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Item number | Type | HxWxD [mm] |
---|---|---|
5999 | KRT1900 | 165x57x60 |
10214 | KRTV19 | 165x57x60 |
Elztrip EZ100 (IP44)
Item number| Type| Heat output
[W]| Voltage [V]| Amperage [A]| Max. surface
temperature
[°C]| Dimensions
LxHxW [mm]| Weight [kg]
---|---|---|---|---|---|---|---
14894| EZ106N| 600| 230V~| 2,6| 320| 870x50x150| 3,2
14895| EZ111N| 1100| 230V~| 4,6| 320| 1470x50x150| 5,4
14896| EZ115N| 1500| 230V~| 6,5| 320| 1950x50x150| 7,0
Heat output
Voltage
Amperage
Max. surface temperature
Weight
Wiring diagrams
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Installation and operating instructions
General Instructions
Read these instructions carefully prior to installation and use. Keep this
manual for future reference.
The product may only be used as set out in the assembly and operating
instructions. The guarantee is only valid should the product be used in the
manner intended and in accordance with the instructions.
Application
EZ100 is a single panel radiant heater with clean and simple design that
blends well with electrical fittings. EZ100 is intended for total and
supplementary heating as well as protection against cold draughts from windows
in environments such as offices, shops, restaurants etc.
The recommended installation heights for the heater are shown on the
introduction pages.
Protection class: IP44.
Operation
The panels have an operating temperature of up to 320 °C and the heat is radiated to cold surfaces. Max. surrounding temperature +30 °C.
Mounting
Elztrip is installed horizontally on ceilings, in armature rails, on cables,
suspended, etc.
Fixtures for easy mounting on the ceiling are included. If the heater is
suspended by wires, use the four mounting points on the heater.
Bracket for wall mounting is available as an accessory. The distance between
panels should not be greater than the height between panel and floor; i.e. (a)
should be less than (H), see illustration on introductory page. For minimum
distance, see diagrams on introductory pages. Ceiling fixtures and screws are
found inside the connection box.
Ceiling mounting
- Mount the ceiling fixtures in the ceiling.
- Open the folded mounting hinges on the top of the heater and hang the heater on the ceiling fixtures. Fig.1. Make sure that the guide pegs are fitted into the holes, to ensure that the heater is fixed in a horizontal position.
- Firmly tighten the screws when finished.
Wall mounting
Bracket for wall mounting is available as an accessory. (EZMVK)
- Mount the wall brackets on the wall according to the dimensional drawing.
- Open the folded mounting hinges on the top of the heater and hang the heater on the wall brackets. Fig.2. Make sure that the guide pegs are fitted into the holes, to ensure that the heater is fixed in a horizontal position.
- Firmly tighten the screws when finished.
Electrical installation
EZ100 is intended for permanent installation.
Connection and serial connection of EZ100 is done with a maximum cable size of
4×2.5 mm² + earth.
The installation, which should be preceded by an isolator switch with a
contact separation of at least 3 mm, should only be wired by a competent
electrician and in accordance with the latest edition of IEE wiring
regulations.
To access the connection box, unscrew and remove the end section. Electrical
installation is performed via cable glands in the junction box on top of the
unit (2 x Ø21 mm). The cable glands used must meet the protection class
requirements.
Control
When using this product as a local space heater according to Ecodesign Regulation (EU) 2015/1188, it must be supplemented with one of the following approved controls.
-
TAP16R, electronic thermostat that includes:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection -
TAP16R and SKG30, black bulb sensor that include:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection
– Black bulb sensor -
TAP16R and PDK65, presence detector that include:
– Electronic room temperature control plus week timer
– Room temperature control with open window detection
– Room temperature control with presence detection
The product can be controlled in a different way, e.g. by an overall control system (BMS), but in that case the responsibility lies with the installer to ensure that the control system is programmed to make the installation meet the requirements of Ecodesign Regulation (EU) 2015/1188.
Start-up
When the unit is used for the first time or after a long period of non-use, smoke or an odour may result from dust or dirt which has collected on the element. This is completely normal and disappears after a short time.
Maintenance
The power supply to the unit must be disconnected during all service, repair and maintenance work. Wait until the unit is cold. The unit has no moving parts so the maintenance requirement is small, but it must be kept clean and free from dust and dirt.
- There might be a rattling noise the first time of use when the surface coating of the panels is settling.
- In all electrical heating appliances, small clicks can occur due to movement when the material expands and contracts with changes in temperature.
- The product should always be handled with clean gloves. Make sure the product is clean before it is switched on.
- Presence of aerosols, lacquer, solvents, dust and similar may cause a coating on the product and discolor them.
- A slight change of colour of the product over time is normal. Incorrect installation or uncommonly high ambient temperature can cause increased discoloration. The output is not affected.
Residual current circuit breaker
When the installation is protected by means of a residual current circuit
breaker, which trips when the appliance is connected, this may be due to
moisture in the heating element. When an appliance containing a heater element
has not been used for a long period or stored in a damp environment, moisture
can enter the element.
This should not be seen as a fault, but is simply rectified by connecting the
appliance to the main supply via a socket without a safety cut-out so that the
moisture can be eliminated from the element. The drying time can vary from a
few hours to a few days. As a preventive measure, the unit should occasionally
be run for a short time when it is not being used for extended periods of
time.
Packaging
Packaging materials are chosen with consideration to the environment and are therefore recyclable.
Handling of product at end of working life
This product may contain substances necessary for the functionality of the product but potentially dangerous for the environment. The product should not be disposed of mixed with general household waste but delivered to a designated collection point for environmental recycling. Please contact the local authority for further details of your nearest designated collection point.
Safety
- For all installations of electrically heated products a residual current circuit breaker 300 mA for fire protection should be used.
- The unit must not be fully or partially covered as overheating can result in a fire risk!
- The unit must not be placed directly under fixed wall sockets!
- The unit must not be used if the unit or the cord is damaged. Risk of injury!
- The cable and plug must not be placed inside the hot radiant area.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Children of less than 3 years should be kept away unless continuously supervised.
- Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION — Some parts of this product can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are
present.
Original instructions
Main office
Frico AB
Industrivägen 41
SE-433 61 Sävedalen
Sweden
Tel: +46 31 336 86 00
mailbox@frico.se
www.frico.net
For latest updated information and information
about your local contact: www.frico.net
Art.no 208956, 2022-07-14 HH/CH