Viper Condenser Fan Installation Instructions
INSTALLATION INSTRUCTIONS VIPER CONDENSER FAN

Safety Instructions

WARNING:
Before starting installation, read and understand all safety label and warnings on the machine. Also review and understand all safety instructions in the owners, installation and service manuals.
Failure to comply could result in serious injury, death or damage to the equipment.
Qualified Service Personnel
WARNING:

Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
All wiring and plumbing must conform to national and local codes. Failure to comply could result in serious injury, death, or equipment damage.
Safety Precautions
This unit has been specifically designed to provide protection against personal injury. To ensure continued protection observe the following:
WARNING:
Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify all of the power is off to the unit before any work is performed. Failure to disconnect the power could result in serious injury, death or equipment damage.
CAUTION:
Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in injury or equipment damage.

Included Components

ITEM PART NUMBER DESCRIPTION QTY. IMAGE
1 620067709 Condenser Fan 1
2 620071490 3pF Capacitor 1

Tools Required

  • 2 Phillips Screwdriver

  • 3/8” Nut Driver or Socket

CAUTION:
Condenser fan PN 620067709 requires a different capacitor than prior fans. Failure to use the proper capacitor will result in reduced performance and may cause equipment damage. Condenser fan PN 620067709 can be identified by its composite blades, while previous fans have metal blades.

Cornelius 620067709 Viper Condenser Fan - PN

INSTALLATION STEPS

  1. Remove Power from the Viper
  2. Using a #2 Phillips screwdriver remove 4 screws to remove the top cladding.Cornelius 620067709 Viper Condenser Fan - INSTALLATION STEPS
  3. Unplug the original condenser fan.Cornelius 620067709 Viper Condenser Fan - INSTALLATION STEPS 1
  4. Using a 3/8” nut driver, remove 4 nuts and washers to remove the original fan.
  5. Using a 3/8” nut driver, install the new fan using the hardware removed in step 4.
  6. Plug in the new condenser fan.Cornelius 620067709 Viper Condenser Fan - Plug
  7. Using a #2 Phillips screwdriver replace the top cladding and 4 screws.
  8. Using a #2 Phillips screwdriver remove 4 screws to remove the rear cladding.
  9. Using a #2 Phillips screwdriver loosen 2 screws to remove the old 4µF fan capacitor.Cornelius 620067709 Viper Condenser Fan - Plug 3
  10. Using a #2 Phillips screwdriver tighten 2 screws to install the new 3µF fan capacitor.Cornelius 620067709 Viper Condenser Fan - Plug 4
  11. Using a #2 Phillips screwdriver replace the rear cladding and 4 screws.
  12. Plug the unit back in and return to service.

Revision Date: July 21, 2023
www.cornelius.com / 800-238-3600
© 2023, Marmon Foodservice Technologies, Inc.
Revision 1.0 – 4 –
Publication Number: 2623515INS

Documents / Resources

| Cornelius 620067709 Viper Condenser Fan [pdf] Instruction Manual
620067709, 620067709 Viper Condenser Fan, Viper Condenser Fan, Condenser Fan, Fan, 620071490
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals