CARISTA COBD-EVO Adapter User Manual

June 13, 2024
CARISTA

CARISTA-LOGO

CARISTA COBD-EVO Adapter

Product Information

Model: COBD-EVO

Using the Carista EVO adapter
The Carista EVO adapter is a device that allows you to connect your car’s onboard diagnostics (OBD) port to your smartphone or tablet. It enables you to access and control various features and settings of your car using the Carista app.

Using the Carista app
The Carista app is a mobile application that works in conjunction with the Carista EVO adapter. It provides a user-friendly interface to interact with your car’s diagnostics and customize certain features. You can download the Carista app from your device’s app store.

Safety Information
Before using the product, it is essential to read and understand all safety information provided. This ensures safe and proper use of the Carista EVO adapter. Please follow all instructions and guidelines mentioned in the user manual.

For additional safety information, you can visit the following link: https://carista.com/adapter-safety

Product Specifications
The product specifications for the Carista EVO adapter are available in the user manual. Please refer to the manual for detailed information on the features, dimensions, and compatibility of the adapter.

Correct Disposal
To ensure proper disposal of the Carista EVO adapter, do not dispose of it with regular household waste. The symbols on the device, accessories, or packaging indicate that it should be collected separately. The packaging materials consist of PAP (cartoon) and PS (plastic).

Compliance
The CE mark on the Carista EVO adapter indicates that it complies with the relevant European health, safety, and environmental protection legislation. The device is in compliance with Directive 2014/53/EU.
You can find the full text of the EU Declaration of Conformity at the following link: https://carista.com/evo-compliance

Additional Information
For more detailed information on using the Carista EVO adapter and compliance details, please refer to the complete user guide available at: https://carista.com/evo-user-guide

Using the Carista EVO adapter

  • Plug the Carista EVO adapter firmly into your car’s OBD port and turn the ignition on.
  • The OBD port is usually located under the dashboard, beneath the steering wheel.
  • Other possible locations include: passenger’s side footwell; hidden behind a recessed panel in your center console; in the armrest or glovebox.
  • Once the Carista EVO adapter is plugged in, you will see a blue light that indicates it is plugged in correctly.
  • Turn on Bluetooth on your phone or tablet, open an app, and connect to it.

Using the Carista app

  • Once you have your OBD adapter plugged in and the ignition on, turn on Bluetooth on your phone or tablet and open the Carista app.
  • Sign in or register a new Carista account (it’s free).
  • Press “Connect” and when prompted for the type of adapter that you’re using, pick “Carista”.
  • Choose from the list of available features for your car and upgrade your driving experience.

Safety Information

Please read and understand all safety information before using the product to ensure safe and proper use. Follow all instructions. You can review more safety information at:
https://carista.com/adapter-safety

⚠️ WARNING

  • Do not connect or disconnect test equipment while the ignition is on or the engine is running.
  • Before starting the engine, put the gear lever in the Neutral position (for manual transmission) or in the Park (for automatic transmission) position to avoid injury.
  • NEVER smoke or allow a spark or flame near the battery or engine. Do not operate the tool in explosive atmospheres, such as in the presence of flammable liquids, gasses, or heavy dust.
  • Keep a fire extinguisher suitable for gasoline/chemical/electrical fires nearby.
  • Keep the tool dry, clean, and free from oil, water, or grease.
  • Keep clothing, hair, hands, tools, test equipment, etc. away from all moving or hot engine parts.
  • Store the tool and accessories in a locked area out of the reach of children.
  • Do not use the tool while standing in water.
  • Do not disconnect the battery or any wiring cables in the vehicle when the ignition switch is on.
  • Do not attempt to install, reconfigure or remove the device from a vehicle while the vehicle is in motion or otherwise in operation.

Product Specifications

  • Frequency Spectrum: 2.402 GHz to 2.480 GHz
  • Receive Sensitivity: -93 dBm (BR/EDR), -93 dBm (LE)
  • Class 1.5 Output Power (10 dBm typical) Adapter Voltage Range: 12V
  • Operating Current: 25 mA
  • Adapter Operating Temperature: -20ºC to +60ºC

Correct Disposal

Do not dispose of electric equipment, accessories and packaging together with household waste material. The symbols on the device, the accessories, or the packaging indicate that this device shall not be treated as unsorted municipal waste, but shall be collected separately. The packaging is made of PAP (cartoon) and PS (plastic).

Compliance
The CE mark on the product indicates that the product complies with the requirements of the relevant European health, safety, and environmental protection legislation.
Simplified Declaration of Conformity Hereby, Prizmos Ltd. declares that the radio equipment type Carista COBD-EVO is in compliance with Directive
2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: https://carista.com/evo-compliance

FCC compliance statement

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a  Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Other product certificates

  • UL Safety certificate
  • EMC Automotive certificate
  • Specific Absorption Rate (SAR) certificate
  • UKCA
  • MIC-JRL
  • ACMA

Additional Information

You can find the complete user guide and compliance information at: https://carista.com/evo-user-guide

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>