EXPLORE SCIENTIFIC WSH0002 Temperature Station Instruction Manual

June 13, 2024
EXPLORE SCIENTIFIC

EXPLORE SCIENTIFIC WSH0002 Temperature Station Instruction Manual
EXPLORE SCIENTIFIC WSH0002 Temperature Station

ABOUT THIS INSTRUCTION MANUAL

These operating instructions are to be considered a component of the device.
Please read the safety instructions and the operating instructions carefully before use.
Keep these instructions for renewed use at a later date. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/user of the product.
The device is intended only for indoor use.

GENERAL WARNINGS

  • risk of electric shock — This device contains electronic components that operate via a power source (power supply and/or batteries). Children should only use the device under adult supervision. Only use the device as described in the manual; otherwise, you run the risk of an electric shock.

  • Choking hazard — Children should only use the device under adult supervision. Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.

  • Risk of chemical burn — Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.

  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or
    improper handling could trigger a short circuit, a fire, or an explosion.

  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.

  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

BEFORE YOU BEGIN

  • We recommend using alkaline batteries. If temperatures regularly fall below 0°C (32°F), we recommend using lithium batteries.
  • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements.)
  • Insert batteries before first use, matching the polarity in the battery compartment. 2x AAA Batteries are required for the station and 2x AAA batteries are required for the sensor.

SCOPE OF DELIVERY

Temperature station, outdoor sensor, Operating instructions, 4x AAA batteries

PRODUCT OVERVIEW

  1. Press to toggle between the time and date display. Press and hold to enter the time and date setting mode.

  2. Press [ ] to show alarm time. Press and hold to enter alarm setting.

  3. Press [ /MAX MAN ] to display temperature MAX/MIN, press and hold to clear max/min memory. In setting mode, press to increase one unit, press and hold to increase rapidly.

  4. Press to view the 3 channel outdoor sensor temperature, press and hold to initialize 3 channel outdoor sensor. In setting mode, press [ ] to decrease one unit, press and hold to decrease rapidly.

  5. Press [ SNOOZE ] to activate the snooze function. The Snooze function will stop the alarm for 5 minutes.
    PRODUCT OVERVIEW

  6. Battery compartment.
    Battery compartment

  7. Press the RESET button to restore settings to factory default.

  8. Battery compartment. Slide down to open.

OUTDOOR SENSOR

  1. Outdoor temperature & humidity LCD display
    OUTDOOR SENSOR

  2. Battery compartment

  3. TX (Initiate main unit search)

  4. Channel switch

  5. C/F switch
    OUTDOOR SENSOR

LCD DISPLAY

  1. Time display or Alarm time display or Date display
  2. Indoor temperature
  3. Outdoor temperature
    LCD DISPLAY

Temperature trend
[ MAX MAN ] MAX / MIN temperature indicator
[ ] Low battery indicator
[ CH ] Channel indicator
[ ] Alarm and Snooze indicator

GETTING STARTED

INSERT BATTERIES

  1. Remove the battery door from the back.
  2. Insert 2x AAA (LR03)/1.5V batteries. Please ensure the polarities (+/-) of the batteries match upon installation.
  3. Reattach the battery door.

OUTDOOR SENSOR
The main unit can receive data from up to 3 outdoor sensors. 1 Sensor is included.

  1. Remove the battery door from the back.
  2. Insert 2x AAA (LR03)/1.5V batteries. Please ensure the polarities (+/-) of the batteries match upon installation.
  3. Select a channel, then press TX.
  4. Reattach the battery door.
  5. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount.

NOTE: Replace batteries when [   displays, or when the display is dim.

CLOCK

SET THE CLOCK MANUALLY

  1. Press and hold [ ] button to enter into time and date setting.
  2. The setting parameter will flash.
  3. Press [ /MAX MAN ] button once, the figure will increase 1 unit. Press and hold the [ /MAX MAN ] button, the figures will increase rapidly.
  4. Press [ ] button once, the figure will decrease 1 unit. Press and hold the [ ] button, the figures will decrease rapidly.
  5. Press [ ] button to confirm setting and enter to next parameter.
  6. Sequence of setting: Zone 12H/24H Year (2000 – 2009) Month Date Hour Minute °C/°F Exit
  7. If there is no action in 20 seconds, the setting will be saved and will exit the setting mode

ALARM

SETTING/ADJUSTING DUAL ALARM TIME

  1. Press the [ ] button to display Alarm.
  2. Press and hold [ ] to enter the alarm setting mode.
  3. The setting parameter will flash.
  4. Press [ /MAX MAN ] or [ ] button to set the desired data.
  5. Press [ ] button to confirm setting and enter to next parameter.
  6. Alarm will turn on automatically when alarm setting is finished.

TURN ON/OFF ALARM
Press the [ ] button display alarm time, then
press [ ] to turn on/off the alarm.

OPERATION

  1. At the set time, alarm signal rings.
  2. During the alarm, press the [ SNOOZE ] button to delay the alarm by 5 minutes.
  3. If you do not press any button to stop the alarm, it will automatically turn off after 2 minutes.
  4. To stop the alarm, press any other button except for [ SNOOZE ].
  5. The alarm will start again at the next alarm time, unless you switch off the alarm function by pressing the [ ] button.

TEMPERATURE

The indoor temperature is always displayed in the middle of the screen. To receive outdoor temperature, you can connect up to 3 outdoor sensors to the main unit, press the [ ] button to toggle between Channel 1-3.

MAX/MIN MEMORY

To toggle between current, minimum and maximum records for the selected sensor, press [ ] repeatedly. To clear records, press and hold [ /MAX MAN ]

SPECIFICATIONS

Dimensions (Main unit):
70x40x100 mm (L x W x H)
Weight (Main unit):
68 g
Temperature display range:
-5°C to +50°C (23°F to 122°F)
Power :
2x AAA (LR03) 1.5V batteries
OUTDOOR SENSOR

Dimensions

60 x 20 x 60 mm (L x W x H)
Weight:
40 g (Exclude batteries)
Transmission range:
30 m (98 ft)
Temperature range :
-20°C to 60°C (-4°F to 140°F)
Signal frequency:
433 MHz

Maximum transmission power:
under 10mW
Power :
2x AAA (LR03) 1.5V batteries

NOTE

  • When the temperature is lower than -5°C (23°F), the temperature displays LL.L. When the temperature is higher than 50°C (122°F), the temperature displays HH.H

EC DECLARATION OF CONFORMITY

CE I Cone Hereby, Flux GmbH declares that the equipment type with part number:
WSH0002 is in compliance with Directive: 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/ download/WSH0002/CE/WSH0002_CE.pdf

RCM DECLARATION OF CONFORMITY

The product complies with electrical safety, EMC and radio spectrum regulatory requirements for products supplied to the Australia or New Zealand market.

NOTES ON CLEANING

  • Remove the batteries before cleaning.
  • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Protect the device from dust and moisture.

DISPOSAL

Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.

Do not dispose of electronic devices in the household garbage! As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.

In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol.

Cd¹
Hg²
Pb³

  1. battery contains cadmium
  2. battery contains mercury
  3. battery contains lead

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.explorescientific.com/ warranty.

MANUAL DOWNLOAD:

EU
  Version:
https ://cutt.ly/OngsHA6

US Version:
www.explorescientific.com/weather-clock- manuals

QR Code

Would you like detailed instructions for this product in a particular language? Then visit our website via the link below (QR code) for available versions.

SERVICE AND WARRANTY:
QR Code
www.explorescientific.com/warranty

Company Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EXPLORE SCIENTIFIC User Manuals

Related Manuals