Two Element
Residential Electric
Water Heaters
ARIER040C2X045N Residential Electric Water Heaters
Use and Care Manual
Installation
Start-Up
Maintenance Parts Warranty
Models:
ARIER040C2X045N / ARIER040C2X055N
ARIER052C2X045N / ARIER052C2X055N
WARNING
This manual must only be used by a qualified installer / service
technician. Read all instructions in this manual before installing.
Perform steps in the given order. Failure to do so could result in substantial
property damage, severe personal injury, or death.
California Proposition 65 Warning: This product contains chemicals known to
the State of California to cause cancer, birth defects, or other reproductive
harm.
NOTICE
Ariston reserves the right to make product changes or updates without notice
and will not be held liable for typographical errors in literature.
The surfaces of these products contacted by potable (consumable) water contain
less than 0.25% lead by weight as required by the Safe Drinking Water Act,
Section 1417.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
SPECIAL ATTENTION BOXES
The following defined terms are used throughout this manual to bring attention
to the presence of hazards of various risk levels or to important product
information.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in serious personal injury or death. WARNIN WARNING indicates a
potentially hazardous situation which, if not avoided, could result in
personal injury or death.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in moderate or minor personal injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, may result in property damage.
NOTICE
NOTICE is used to address practices not related to personal injury.
Foreword
This manual is intended to be used in conjunction with other literature
provided with the water heater. This includes all related control information.
It is important that this manual, all other documents included in this system,
and additional publications be reviewed in their entirety before beginning any
work.
Installation should be made in accordance with the regulations of the
Authority Having Jurisdiction, local code authorities, and utility companies
which pertain to this type of water heating equipment.
Authority Having Jurisdiction (AHJ) – The AHJ may be a federal, state,
local government, or individual such as a fire chief, fire marshal, chief of a
fire prevention bureau, labor department or health department, building
official or electrical inspector, or others having statutory authority. In
some circumstances, the property owner or his/her agent assumes the role, and
at government installations, the commanding officer or departmental official
may be the AHJ.
NOTE: Ariston reserves the right to modify product technical
specifications and components without prior notice.
For the Installer
This water heater must be installed by qualified and licensed personnel.
The installer should be guided by the instructions furnished with the water
heater, and by local codes and utility company requirements.
Installations Must Comply With:
Local, state, provincial, and national codes, laws, regulations, and
ordinances.
The latest version of the National Electrical Code, NFPA No. 70.
For Your Records
Write the Product Model and Serial Numbers:
Model # ___
Serial # ____
These numbers are listed on the product ratings label.
Keep this manual and information for future reference.
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions to reduce the risk
of fire, electric shock, or injury to persons should be followed, including:
- READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.
- This water heater must be grounded. Connect only to a properly grounded outlet. See Part 4 – Wiring, this manual, for grounding details.
- Install or locate this water heater only in accordance with the provided installation instructions.
- Use this water heater only for its intended use as described in this manual.
- Do not operate this water heater if it has been damaged or dropped.
- This water heater should be serviced only by qualified service personnel. Contact the water heater installer or a qualified service agency for examination, repair, or adjustment.
SAVE THESE INSTRUCTIONS
From the Uniform Plumbing Code 2000 – Section 510 -Protection From Damage
- Water heaters generating a glow, spark or flame capable of igniting flammable vapors may be installed in a garage, provided the pilots, burners or heating elements and switches are at least eighteen (18) inches (457 mm) above the floor level.
- Where such water heaters installed within a garage are enclosed in a separate, approved compartment having access only from outside of the garage, such water heaters may be installed at floor level provided the required combustion air is also taken from the exterior of the garage. Fuel burning water heaters having sealed combustion chambers need not be elevated.
- All water heaters installed in areas where they may be subjected to mechanical damage shall be suitably guarded against such damage by being installed behind adequate barriers or by being elevated or located out of the normal path of a vehicle using any such garage.
- In seismic zones 3 and 4, water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third (1/3) and lower one-third (1/3) of its vertical dimensions. At the lower point, a minimum distance of four (4) inches (102 mm) shall be maintained above the controls with the strapping.
- An water heater supported from the ground shall rest on level concrete or other approved base extending not less than three (3) inches (76 mm) above the adjoining ground level.
- When an water heater is located in an attic, attic-ceiling assembly, floor-ceiling assembly, or floor-subfloor assembly where damage may result from a leaking water heater, a watertight pan of corrosion resistant materials shall be installed beneath the water heater with a minimum three-quarter (3/4) inch (20 mm) diameter drain to an approved location.
NOTE: If the water heater is exposed to the following, do not operate. Immediately call a qualified service technician.
- Fire
- Damage
- Water
Failure to follow this information could result in property damage, severe personal injury, or death.
Part 1 – General Safety Information
This water heater is approved for indoor installations only and is not
intended for use as a pool heater. Clearance to combustible materials: 0” top,
bottom, sides, and back. Heater must have room for service: 24” front, 6” top,
and 6” sides are minimum recommended service clearances. (A combustible door
or removable panel is acceptable front clearance.) This water heater has been
approved for closet installation and installation on combustible flooring. Do
not install directly on carpeting. Install the water heater in a location
where temperature and pressure relief valve discharge or a leak will not
result in damage to the surrounding area. If such a location is not available,
install an auxiliary catch pan.
WARNING
Installer – Read all instructions in this manual before installing.
Perform steps in the given order.
User – This manual is for use only by a qualified heating installer/
service technician. Have this water heater serviced / inspected annually by a
qualified service technician.
FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE CAN RESULT IN SUBSTANTIAL
PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN SUBMERGED IN WATER.
Immediately call a qualified service technician. The water heater MUST BE
replaced if it has been submerged. Operating a previously submerged water
heater could result in property damage, severe personal injury, or death.
NOTE: Water heater damage due to flood or submersion is considered an Act
of God, and IS NOT covered under product warranty.
NOTE: Obey all local codes. Obtain all applicable permits before
installing the water heater.
NOTE: Install all system components and piping in such a manner that does
not reduce the performance of any fire rated assembly.
CAUTION
High heat sources (sources generating heat 100 °F / 37° C greater, such as
stove pipes, space heaters, etc.) may damage plastic components of the water
heater as well as plastic vent pipe materials. Such damages ARE NOT covered by
warranty. It is recommended to keep a minimum clearance of 8” from high heat
sources. Observe heat source manufacturer instructions, as well as local,
state, provincial, and national codes, laws, regulations and ordinances when
installing this water heater and related components near high heat sources.
Do not use this water heater for anything other than its intended purpose (as
described in this manual). Doing so could result in property damage and WILL
VOID product warranty.
NOTICE
UNCRATING THE WATER HEATER – Any claims for damage or shortage in shipment
must be filed immediately against the transportation company by the consignee.
A. When Servicing the Water Heating System
WARNING
Be sure to disconnect electrical power before performing service.
Failure to do so could result in electrical shock, property damage, serious
personal injury, or death.
NOTE: When inquiring about service or troubleshooting, reference the
model and serial numbers from the water heater rating label.
To avoid severe burns, allow water heater and associated equipment to cool
before servicing.
B. Heater Water
Do not use petroleum-based cleaning or sealing compounds in a water heating
system. Gaskets and seals in the system may be damaged. This can result in
substantial property damage.
Do not use “homemade cures” or “patent medicines”. Damage to the water heater,
substantial property damage, and/or serious personal injury may result.
C. Freeze Protection
NOTE: Consider piping and installation when determining heater location.
Failure of the water heater due to freeze related damage IS NOT covered by
product warranty.
WARNING
NEVER use any toxic chemical, including automotive, standard glycol
antifreeze, or ethylene glycol made for hydronic (non-potable) systems. These
chemicals can attack gaskets and seals in water systems, are poisonous if
consumed, and can cause personal injury or death.
D. Water Temperature Adjustment
thermostat is factory set at 125°F (51,7°C) or lower to reduce the risk of
scalding injury .
If the water heater is going to have a set temperature above 120o F, it is
recommended to use an ASSE 1017 rated mixing valve to avoid severe burns or
death from scalding temperatures.
WARNING
Households with small children, disabled, or elderly persons may require a
120oF or lower temperature setting to prevent severe personal injury or death
due to scalding.
Approximate Time / Temperature Relationships in Scalds
120°F | More than 5 minutes |
---|---|
125 °F | 1 1/2 to 2 minutes |
130°F | About 30 seconds |
135°F | About 10 seconds |
140°F | Less than 5 seconds |
145°F | Less than 3 seconds |
150°F | About 1 1/2 seconds |
155°F | About 1 second |
Table 1 – Approximate Time / Temperature Relationships in Scalds
Part 2 – Prepare the Water Heater
Remove all sides of the shipping crate to allow the heater to be moved into
its installation location.
CAUTION
COLD WEATHER HANDLING – If the water heater has been stored in a very
cold location (BELOW 0°F) before installation, handle with care until the
components come to room temperature. Failure to do so could result in damage
to the water heater.
A. What’s in the Box
Components included with the water heater:
- Drain Valve
- Temperature and Pressure Relief Valve
- Insulation
- Hot Water Outlet
- Dip Tube
- Use and Care Manual and Warranty
NOTE: Some components may ship factory installed.
B. Locating the Water Heater
CAUTION
All water heaters eventually leak. Locate the water heater where any
leakage from the relief valve, related piping, tank, or connections will not
result in damage to surrounding areas or lower floors of the building. Any
water heater should be installed in such a manner that if it should leak the
resulting flow of water will not cause damage to the area in which it is
installed. National Plumbing codes require a drain pan for any water heater
installation. This drain pan should be sized with a maximum depth of 2”, and a
minimum diameter 2” greater than the diameter of the water heater. The drain
pan should empty into an open drain line. This drain line should be 3/4” ID
minimum, piped to an open drain. Leakage damages ARE NOT covered by warranty.
Failure to install a drain pan is the sole responsibility of the owner and/or
installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510 – Protection
from Damage or IPC 200 (International Plumbing code) Section 504 – Safety
Devices. Leakage damages ARE NOT covered by warranty. In addition, water leak
detection devices and automatic water shutoff valves are readily available at
plumbing supply houses. IT IS HIGHLY RECOMMENDED BY THE MANUFACTURER TO
INSTALL WATER LEAK DETECTION DEVICES AND AUTOMATIC SHUTOFF VALVES IN ANY WATER
HEATER INSTALLATION WHERE A LEAKAGE OF WATER COULD RESULT IN PROPERTY DAMAGES.
WARNING
This water heater is certified for indoor use only. DO NOT INSTALL OUTDOORS.
Outdoor installations ARE NOT covered by warranty. Failure to install the
water heater indoors could result in property damage, severe personal injury,
or death.
1. Installation Area (Mechanical Room) Operating Conditions
- Ensure ambient temperatures are higher than 32 F /°C and lower than 104o o F / 40°C
- Avoid continuously high levels of humidity
- Never close existing ventilation openings
NOTE: When installing in a zero clearance location, it may not be
possible to read or view some product labeling. It is recommended to make note
of the water heater model and serial number.
NOTE: A combustible door or removable panel is acceptable front
clearance.
CAUTION
The service life of the water heater’s exposed metallic surfaces, such as the
junction box, is directly influenced by proximity to damp and salty marine
environments. In such areas higher concentration levels of chlorides from sea
spray coupled with relative humidity can lead to degradation of water heater
components.
WARNING
Incorrect operating conditions can lead to damage to the heating system and
put safe operation at risk. Ensure that the installation location adheres to
the information included in this manual. Failure to do so could result in
property damage, serious personal injury, or death. Failure of the water
heater or components due to incorrect operating conditions IS NOT covered by
product warranty.
This water heater must be installed upright in the vertical position as
described in this manual. DO NOT attempt to install this water heater in any
other orientation. Doing so will result in improper water heater operation and
property damage, and could result in serious personal injury or death.
2. Choose a location for the water heater as centralized to the piping and
electrical system as possible. Also, locate the water heater and domestic
water piping where it will not be exposed to freezing temperatures. All piping
should be insulated. Additionally, place the water heater so that the drain,
controls, and inlets/outlets are easily accessible.
NOTE: To save on heating costs and improve energy efficiency keep the
distance between the water heater and fixtures to a minimum to reduce heat
loss from excess piping and keep friction loss at a minimum. Ensure all water
heater piping is properly insulated to minimize heat loss.
NOTE: If you do not provide the minimum clearances shown in Figure 1, it
might not be possible to service the water heater without removing it from the
space.
NOTE: In the State of California, the water heater must be braced,
anchored, or strapped to avoid moving during an earthquake. Contact local
utilities for code requirements in your area. Visit
http://www.dsa.dgs.ca.gov or call
1-916-445-8100 and request
instructions.
However, applicable local codes shall govern installation. For residential
water heaters of a capacity of greater than 52 gallons, consult the local
building jurisdiction for acceptable bracing procedures.
3. Check area around water heater. Remove any combustible materials,
gasoline, and other flammable liquids.
Figure 1 – Recommended Service Clearances – NOTE: Overhead View Not
Representative of All Models
DANGER
This water heater must not be located near flammable liquids such as gasoline,
butane, liquefied propane, adhesives, solvents, paint thinners, etc., as the
controls of this water heater could ignite these vapors and cause an explosion
resulting in property damage, severe personal injury, or death.
4. If the water heater is to replace an existing water heater, check for and
correct any existing system problems such as:
- System leaks
- Location that could cause the system and water heater to freeze and leak
- Incorrectly-sized expansion tank
5. This water heater must be installed vertical on a level surface.
C. Water Chemistry Requirements
CAUTION
Chemical imbalance of the water supply may affect efficiency and cause severe
damage to the appliance and associated equipment.
Water quality must be professionally analyzed to determine whether it is
necessary to treat the water. Various solutions are available to adjust water
quality. Adverse water quality will affect the reliability of the system. In
addition, operating temperatures above 135 oF will accelerate the build-up of
lime scale and possibly shorten appliance service life. Failure of an
appliance due to lime scale build-up, low pH, or other chemical imbalance IS
NOT covered by the warranty.
The water must be potable, free of corrosive chemicals, sand, dirt, and other
contaminates. It is up to the installer to ensure the water does not contain
corrosive chemicals or elements that can damage the heat exchanger. Potable
water is defined as drinkable water supplied from utility or well water in
compliance with EPA secondary maximum contaminant levels (40 CFR Part 143.3).
If the water contains contaminants higher than outlined by the EPA, water
treatment is recommended and additional, more frequent
maintenance may be required. If you suspect that your water is contaminated in
any way, discontinue use of the appliance and contact an authorized technician
or licensed professional.
- Water pH between 6.5 and 8.5
- pH levels below 6.5 can cause an increase in the rate of corrosion. pH of 8.5 or higher can potentially cause lime scale build-up
- Maintain water pH between 6.5 and 8.5. Check with litmus paper or have it chemically analyzed by a local water treatment company.
- If the pH is not between 6.5 and 8.5, consult a local water treatment company for solutions.
- Hardness less than 12 grains (200 mg/L) (Residential Use – water temperatures below 140o F)
- Hardness levels above the required amounts can lead to lime scale build-up throughout the system. Water below 5 grains/ gallon (85 mg/L) may be over softened.
- Consult local water treatment companies for unusually hard water areas (above the required amounts) or for other treatment solutions if water is being over softened (below 5 grains/gallon [85 mg/L]).
- Chloride concentration less than 100 ppm (mg/L)
- Do not fill appliance or operate with water containing chlorides in excess of 100 ppm (mg/L).
- Using chlorinated fresh water should be acceptable as levels are typically less than 5 ppm (mg/L).
- Do not connect the appliance to directly heat swimming pool or spa water.
- Total Dissolved Solids (TDS) less than 500 ppm (mg/L)
- Total dissolved solids are minerals, salts, metals, and charged particles that are dissolved in water.
- The greater the amounts of TDS present, the higher the corrosion potential due to increased conductivity in the water.
- If using softened water to fill the appliance, it is still possible to have high TDS. This water can be corrosive. Consult local water treatment companies for other treatment solutions to reduce this affect.
*NOTE: To promote appliance service life, it is strongly recommended to
follow the maintenance procedures in this manual.
CAUTION
Failure of electric elements due to lime scale build-up on the heating
surface, low pH, or other imbalance IS NOT covered by the warranty.
Specifications and Dimensions | Water Temperature Ratings |
---|---|
Residential Models | Storage Capacity |
Listing | Hot / Cold |
Inlets | Shipping Weight |
(Lbs. Est.) | Min. Delivered |
Temp. | Max. Delivered |
Temp. | High Temp. |
Limit
ARIER040C2X045N| 40| 5 3/4″| 46″| 54 1/4″| 19 1/2″| 8″| UL 174| 3/4″ NPT| 104|
110°F
(43.3 C)| 150°F
(65.5 C)| 170°F
(76.6 C)
ARIER040C2X055N
ARIER052C2X045N| 52| 58 1/4″| 66 3/4″| 118
ARIER052C2X055N
Table 2 – Specifications and Dimensions – See Table 3 for Electrical Specifications
Model #| # Elements and Thermostats| Available Wattage| Voltage| Full Load
Current in Amps (Single Phase)
---|---|---|---|---
ARIERC2X045N| 2| 4,500| 240| 19
ARIERC2X055N| 2| 5,500| 240| 23
Table 3 – Electrical Specifications Including Corresponding Wattages /
Voltages / Amperages
* Refers to Model Type and Gallon Size – See Table 2 for Model
Specifications and Dimensions
INSTALLING COLD INLET AND HOT OUTLET FITTINGS**
Figure 3 – Installing Cold Inlet and Hot Outlet Fittings
- THE HOT WATER AND COLD WATER FITTINGS MUST BE INSTALLED IN THE ORIENTATION SHOWN IN THESE DIRECTIONS OR THE HEATER WARRANTY WILL BE VOIDED.
- IT IS REQUIRED TO INSTALL THE COLD WATER DIP TUBE INTO THE TANK PRIOR TO FITTING INTO AREAS WITH LOW CEILING HEIGHT.
- PLEASE USE TAPE AND PIPE DOPE WITH TEFLON TO SEAL FITTINGS INTO THE TANK.
- NOTE: DO NOT APPLY HEAT TO THE HOT OR COLD WATER CONNECTIONS. THESE FITTINGS ARE EQUIPPED WITH PLASTIC AND RUBBER HEAT TRAPS THAT WILL BE DAMAGED IF HEAT IS APPLIED. IF SWEAT CONNECTIONS ARE USED, SWEAT TUBING TO ADAPTER BEFORE FITTING ADAPTER TO THE WATER HEATER CONNECTION.
CAUTION
The Cold Inlet and Hot Outlet Fittings MUST BE INSTALLED according to the
steps in Figure 3 for the electric water heater to operate properly. Failure
to install these fittings properly will result in improper water heater
operation, possible substantial property damage, and increased costs. Service
calls to repair the installation and properly install these fittings ARE NOT
COVERED by water heater warranty. Improper installation WILL VOID the water
heater warranty.
Part 3 – Piping
A. Plumbing
It is mandatory that all plumbing be done in accordance with federal, local,
and state plumbing codes and practices. Failure to properly install the water
heater WILL VOID the warranty. It is also necessary to use both thread tape
and pipe sealing compound on all mechanical plumbing connections.
It is recommended to use unions on the hot and cold water connections to
easily disconnect the water heater for servicing.
CAUTION
Dielectric unions or galvanized steel fittings must not be used in a system
with this water heater. Doing so WILL VOID the warranty. It is recommended to
use only copper, brass, or stainless steel fittings.
Teflon thread sealant must be used on all connections.
1. Install a shut-off or check valve or both on the inlet connection on the
top of the heater. Connect the cold water supply line to the shutoff valve or
check valve. Refer to piping Applications, this manual.
CAUTION
Do not apply heat to the Hot or Cold water heater connections. If sweat
connections are used, sweat tubing to the adapter before fitting adapter to
the water connections on the heater. Any heat applied to the water heater
connections will permanently damage the dip tube and/or heat traps. Damages
due to improper installation practices ARE NOT covered by warranty.
2. Connect the hot water line to the connection marked “HOT” on the top of
the water heater.
3. Install the T&P Valve in the opening provided near the top of the heater.
4. Install drain valve in the opening provided near the bottom of the heater.
B. Thermal Expansion
A check valve may be installed in the cold water inlet line as a separate
backflow preventer, or may be part of a pressure reducing valve, water meter,
or water softener. An “open water system” refers to a system without a check
valve. A “closed water system” refers to a system with a check valve installed
in the cold water inlet line.
As water is heated, it expands in volume and increases pressure within the
water system. This action is referred to as “thermal expansion”. In an open
water system, expanding water which exceeds the capacity of the system flows
back into the city main where pressure is easily dissipated.
A closed water system prevents expanding water from flowing back to the city
main. The resulting thermal expansion can rapidly increase pressure in the
water heater and system piping. This rapid pressure increase can exceed the
setting of the pressure relief valve, causing it to operate during each
heating cycle, resulting in discharge from the T&P. This rapid and repeated
expansion and contraction of components in the system can cause premature
failure of system components, including the relief valve and possibly the
water heater. Replacing the relief valve will not correct thermal expansion.
A potable hot water expansion tank is required to offset thermal expansion.
Expansion tanks are designed with an air cushion built in that compresses as
system pressure increases, thereby relieving the overpressure condition and
eliminating repeated operation of the relief valve. This expansion tank should
be installed in the cold water line between the water heater and check valve,
and must be sized for the entire water volume of the hot water system. See
piping Applications.
Other methods of controlling thermal expansion are available. Check with the
local water utility to determine if a check valve exists in the cold water
inlet line. Contact your installing contractor, water supplier, or plumbing
inspector for additional information regarding thermal expansion.
C. Condensation
Condensation can form on the water heater when it is first filled with water,
and may also occur with a heavy water draw and very cold inlet water
temperature. This condition is not unusual and will disappear as the water
becomes heated. However, if the condensation should continue, examine the
piping and fittings for possible leaks.
D. Insulation Blankets
WARNING
If local codes require external application of insulation blanket kits, the
manufacturer’s instructions included with the kit must be carefully followed.
In addition, pay careful attention to the following so as not to restrict the
proper function and operation of the water heater:
- Do not cover the operating or warning labels attached to the water heater or attempt to locate them on the exterior of the insulation blanket.
- Do not apply insulation to the top of the water heater. This could interfere with the safe operation of the electrical junction box.
- Do not cover the jacket access panel(s) to the thermostat(s) and heating element(s) or T&P valve.
- Inspect the insulation blanket frequently.
Failure to follow these instructions could result in property damage, severe
personal injury, or death.
CAUTION
E. Temperature and Pressure Relief Valve
For protection against excessive pressures and temperatures in this water
heater, install temperature and pressure protective equipment as required by
local codes, but not less than a combination T&P valve meeting the
requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water
Supply Systems, ANSI Z21.22B / CSA 4.4M99 by a nationally recognized testing
laboratory that maintains periodic inspection of production listed equipment
and materials. This valve must be marked with a maximum set pressure not to
exceed the marked maximum working pressure of the water heater. Install the
T&P valve into the opening provided and marked for this purpose on the water
heater. The T&P valve must be plumbed down so discharge can exit at least 6”
above the structural floor. The relief line cannot be in contact with any live
electrical parts.
To avoid water damage or scalding due to relief valve operation:
- Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge.
- Discharge line must be as short as possible and the same size as the valve discharge connection throughout its entire length.
- Discharge line must pitch downward from the valve and terminate at least 6” above the floor drain, making discharge clearly visible.
- The discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375 °F or greater.
- Do not pipe discharge to any location where freezing could occur.
- No valve may be installed between the relief valve and heater or in the discharge line. Do not plug or place any obstruction in the discharge line.
- Test the operation of the relief valve after filling and pressurizing the system by lifting the lever. Make sure the valve discharges freely. If the valve fails to operate correctly, immediately replace with a new properly rated relief valve.
- Test T&P valve at least once annually to ensure the waterway is clear. If valve does not operate, turn the heater “off” and call a plumber immediately.
- Take care whenever operating relief valve to avoid scalding injury or property damage.
FAILURE TO COMPLY WITH THESE GUIDELINES COULD RESULT IN FAILURE OF RELIEF
VALVE OPERATION, RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE,
SEVERE PERSONAL INJURY, OR DEATH.
RE-INSPECTION OF T&P RELIEF VALVES: T&P valves should be inspected AT LEAST
ONCE EVERY THREE YEARS, and replaced if necessary, by a licensed plumbing
contractor or qualified service technician to ensure that the product has not
been affected by corrosive water conditions and to ensure that the valve and
discharge line have not been altered or tampered with illegally. Certain
naturally occuring conditions may corrode the valve and its components over
time, rendering the valve inoperative. Such conditions can only be detected if
the valve and its components are physically removed and inspected. Do not
attempt to conduct an inspection on your own. Contact your plumbing contractor
for a re-inspection to assure continued safety.
FAILURE TO RE-INSPECT THE T&P VALVE AS DIRECTED COULD RESULT IN UNSAFE
TEMPERATURE AND/OR PRESSURE BUILDUP WHICH CAN RESULT IN PROPERTY DAMAGE,
SERIOUS PERSONAL INJURY, OR DEATH. Do not thread a cap or plug into the relief
valve or block relief valve outlet line under any circumstances! Explosion and
property damage, serious injury, or death may result.
F. Scalding
WARNING
An ASSE 1017 or ASSE 1070 temperature limiting or mixing valve is
recommended in installations servicing disabled or elderly persons, or
children. Mixing valves can reduce but do not eliminate the risk of scalding.
To avoid scalding:
- Set the water heater set point temperature as low as possible.
- Feel water before bathing or showering.
- If thermostatic valves are required, use devices specifically designed for such purpose. Install these devices in accordance with instructions provided by the manufacturer.
Failure to install a temperature limiting or mixing valve and follow these
instructions could result in property damage, severe personal injury, or death
due to scalds.
This water heater can deliver scalding water. Be careful whenever using hot
water to avoid scalding injury. Certain appliances such as dishwashers and
automatic clothes washers may require increased water temperatures. By setting
the thermostat on this heater to obtain the increased water temperature
required by these appliances you may create the potential for scald injury.
To protect against injury, install a mixing valve in the water system. This
valve will reduce point of use discharge temperatures by mixing cold and hot
water in branch supply lines. Such valves are available from your local
plumbing supplier. Table 1 details the relationship of water temperature and
time with regard to scald injury and may be used as a guide in determining the
safest water temperature for your applications.
DANGER Water
temperature over 125°F can cause severe burns instantly or death from scalds.
Children, disabled and elderly are at highest risk of being scalded. See
instruction manual before setting temperature at water heater. Feel water
before bathing or showering. Temperature limiting valves are available, see
manual.
G. Filling the Heater
- Make certain that the drain valve is completely closed.
- Open the shut-off valve in the cold water supply line.
- Open the hot water faucets to allow air to vent from the heater and piping.
- Allow sufficient time for the heater to completely fill with water.
- Verify elements are installed correctly. Check for leaks.
CAUTION
When filling the water heater, open a hot water tap to release air in the tank
and piping. The tank must be full of water before the heater is turned on.
Failure to ensure the water heater is full before turning it on could result
in damage to the water heater and other property damages. Such damages ARE NOT
covered by water heater warranty.
H. Applications Figure 4 –
Piping Detail – NOTE: Drawing is meant to demonstrate system piping concept.
Heat traps are optional.
PIPING NOTES:
- Minimum pipe size should match connection size. Upsize pipe accordingly if greater flow is required.
- A thermal expansion tank suitable for potable water must be sized and installed within this piping system between the backflow preventer and the cold water inlet.
- All circulators should have an integral flow check.
- Drains and check valve between unit and storage tank will assist in purging air from system.
- These drawings are meant to demonstrate system piping only. The installer is responsible for all equipment and detailing required by local codes. In Massachusetts, you must install a vacuum relief valve per 248 CMR.
- Mixing valve application is optional, but recommended to help prevent scalding. See Part 3 for more information.
Part 4 – Wiring
Tank must be full of water before the power is turned on. Heating elements
will be damaged if energized for even a short time while tank is dry. Failures
due to “dry-firing” ARE NOT covered by warranty. This unit is factory wired to
a junction box on top of the water heater for field wiring connection. These
heaters are equipped and wired for the maximum possible input allowable (see
Table 3 for listing of inputs and amperage requirements). The voltage
requirement and dedicated wattage load for the heater is specified on the
rating label of the water heater. Consult your local power company to
determine if your electrical service is adequate for the additional load of
the heater.
ahl-631 Revision Date 7.12.23
WARNING
Refer to the wiring diagrams for field connections. All wiring must conform to
local code and the National Electric Code, and should be done by a qualified
licensed electrician or the local electric utility. Grounding can be
accomplished by using approved conduit and fittings or other approved
conductive material. A grounding wire is provided on the junction bracket.
This grounding wire must be used in the installation.
Be sure to ground the water heater. The preferred way to ground is with rigid
metal conduit between the main panel and the water heater junction box with
approved end fittings (check codes on the use of flexible conduit). If making
a separate ground, a green ground wire is provided in the water heater
junction box. Replace the junction box cover and insulation after you have
made the wiring connections. Failure to follow these instructions could result
in property damage, severe personal injury, or death.Figure 5 – Dual Element Model Wiring Detail, Staged
Element Operation – Green Wire for Grounding the Water Heater
Part 5 – Installation Checklist
Water Heater Location | Yes | No |
---|---|---|
Close to area of heated water demand | ||
Indoors and protected from freezing temperatures | ||
Area free of flammable vapors |
Provisions made to protect area from water damage and control thermal
expansion| |
Sufficient room to service heater| |
Relief Valve| Yes| No
Temperature and Pressure Relief Valve properly installed and discharge line
run to open drain| |
Discharge line protected from freezing| |
**Wiring**
| **Yes**
| **No**
Power supply voltage agrees with water heater rating plate| |
Branch circuit wire and fusing or circuit breaker of proper size| |
Electrical connections tight and unit properly grounded| |
Water Supply| Yes| No
Water heater completely filled with water BEFORE operating the unit| |
Air purged from water heater and piping| |
Water connections tight and free of leaks| |
Table 4 – Installation Checklist
Part 6 – Operation
CAUTION
Tank must be full of water before the power is turned on. Heating elements
will be damaged if energized for even a short time while tank is dry. Failures
due to “dry-firing” ARE NOT covered by warranty.
After water and electrical connections have been made and tank is filled with
water, turn on power to the heater. The heater is now in operation.
A. Combination Thermostat and High Limit Control (ECO)
Each water heater is equipped with a combination Thermostat – High Limit
Control (ECO). Thermostats are located above the heating elements. If for any
reason the water temperature becomes excessively high, the ECO breaks the
circuit to the heating element.
Once the switch opens it must be reset manually. However,
THE CAUSE OF THE OVER TEMPERATURE CONDITION MUST BE CORRECTED FIRST.
WARNING
The cause of the high temperature condition must be investigated by a
qualified service technician and corrective action must be taken BEFORE
placing the water heater back in service. Failure to do so could result in
property damage, severe personal injury, or
death.
B. Thermostat Adjustment and ECO Reset
There are two thermostats on dual element heaters. If temperature adjustment
is necessary, TURN OFF POWER TO HEATER, remove black access cover and
insulation. The thermostat protective cover SHOULD NOT be removed. Set
temperature indicator to desired temperature. Replace insulation and the black
access cover. Turn on power to the heater.
DANGER
Failure to disconnect the power from the water heater before attempting to
adjust or reset the thermostat(s) will result in property damage, severe
personal injury, or death.
IF YOU NEED TO ADJUST THERMOSTAT(S) OR RESET THE ECO (RED RESET BUTTON)
STEP #1 – Turn off power to the water heater by removing fuse or shutting off
at circuit breaker.
STEP #2 – Remove the two screws that hold the access cover in place. Remove
the cover.
STEP #3 – Remove the insulation to expose the thermostat.
STEP #4 – See Figure 11 a. Reset the ECO by pushing in the red button marked
“RESET”.
b. Adjust the water temperature by turning the white adjustment knob. Turning
the knob to the right (clockwise) makes the water hotter. Turning the knob to
the left (counterclockwise) makes the water cooler.
Step #5 – Replace the insulation.
Step #6 – Reattach the access cover with the two screws.
Step #7 – Restore power by replacing the fuse or turning on the circuit
breaker.
Step #8 a. After resetting the ECO, ensure the water heater is operating
properly before leaving the installation.
b. After adjusting the water temperature, allow the water heater enough time
to heat the water to temperature. After the water heater has stopped heating,
measure the water temperature at a hot water outlet in the structure.
Step #9 – If the water heater is operating properly and the water temperature
is satisfactory, adjustment is complete. DANGER Water temperature over 125T can cause severe
burns instantly or death from scalds. Children, disabled and elderly are at
highest risk of being scalded. See instruction manual before setting
temperature at water heater. Feel water before bathing or showering.
Temperature limiting valves are available, see manual.
WARNING
Risk of scald injury increases as you increase water temperature.
Failure to replace insulation or access cover could result in property damage,
severe personal injury, or death.
C. Heating Element Replacement Procedure
WARNING
If heating elements need replacement, it is very important to use the same
voltage, wattage, and construction. DO NOT replace heating element with a
generic heating element. Only Ariston heating elements are approved for use
with this water heater. Failure to
follow this warning will result in premature product failure and VOID the
warranty, and could result in severe personal injury or death.
STEP #1 – Turn off power to the water heater. Use a Phillips Head
screwdriver to remove the wires from the element.
DANGER
Failure to disconnect the power from the water heater before attempting
heating element replacement will result in property damage, severe personal
injury, or death due to electric shock.
STEP #2 – Run hot water at a faucet in the system. When it runs cold, shut off
the faucet. Then shut off water at the main cold water inlet or, if possible,
valve off the water heater from the system. Drain the water from the system,
or just the water heater if it can be isolated from the system.
WARNING
Completely drain the water heater before removing and replacing a heating
element or elements. Failure to do so will result in a leakage of water and
property damage, and could possibly result in moderate to severe personal
injury or death. Water drained from the water heater may be scalding hot. Take
care to avoid scalding. Wear gloves and safety glasses, and direct water to a
safe drainage location. Failure to comply with this warning could result in
property damage, severe personal injury, or death.
Step #3 – Remove the element with a 1 1/2” socket wrench or element tool.
Step #4 – Inspect the removed element. Determine whether the replacement
element will need a square or circular gasket and washer.
Step #5 – Ensure thread and opening are completely free of debris. Use a
nylon brush to clear away any debris. Step #6 – Put a small amount of NSF approved
lubricant and sealant on the appropriate gasket and/or washer for the
installation. Put the gasket and/or washer on the element.
Step #7 – Screw the element clockwise into the tank, and tighten with the
1 1/2” socket wrench or element tool. Be sure gasket seats properly.
NOTE: Repeat Steps 3 – 6 as Necessary for Multiple Elements Step #8 –
Open the main cold water inlet. If the water heater has been isolated from the
system, open the valves. Refill the tank with cold water. Open a hot water
faucet high in the system to bleed any air pressure from the system. Water
will flow freely when air is completely bled.
WARNING
When filling the water heater, open a hot water tap to release air in the tank
and piping. The tank must be full of water before the heater is turned on.
Failure to ensure the water heater is full before turning it on will result in
damage to the water heater, and could
result in property damage, serious personal injury, or death. Such damages ARE
NOT covered by water heater warranty.
Step #9 – Pressure check the tank for leaks around element. If no leaks
are found, use a Phillips Head screwdriver to connect the wires to the
element.
Step #10 – Turn power back on to the water heater.
CAUTION
Failure to refill the tank before restoring power to the water heater will
result in damage to the heating elements and property damage. Such damages ARE
NOT covered by warranty.
Part 7 – Maintenance
Considerations
- To avoid electric shock, disconnect electrical supply before performing maintenance.
- To avoid severe burns, allow heater to cool before performing maintenance.
NOTE: In addition to the routine maintenance detailed in this manual,
this water heater should be inspected annually by a qualified service
technician to assure that all the equipment is operating safely and
efficiently. The owner should make necessary arrangements with a qualified
heating contractor for periodic maintenance of the heater. Installer must also
inform the owner that lack of proper care and maintenance may result in a
hazardous condition, premature heater failure, and void the warranty.
Routine preventative maintenance ensure the water heater operates safely and
efficiently over its service life. The Owner / User may perform the
maintenance activities described below.
Monthly (Every two weeks in hard water locations)
It is recommended that a few quarts of water be drained from the heater. This
will flush sediment deposits from the bottom of the heater and lengthen the
heater’s service life. Turn off power to the heater during flushing operation,
so the elements will not be damaged.
CAUTION
Failure to shut off the heater when draining may damage the heating elements.
Operating a partially filled / empty water heater could lead to damage from
“dry-firing”. Failures due to such damage ARE NOT covered by warranty.
WARNING
Water drained from the water heater may be scalding hot. Take care to avoid
scalding. Wear gloves and safety glasses, and direct water to a safe drainage
location. It is recommended to turn power off to the water heater and run
water at a hot water faucet until it cools BEFORE draining water from the
heater. Failure to comply with this warning could result in property damage,
severe personal injury, or death.
To flush the tank, attach a hose to the field installed drain valve. Close the
cold water supply line shut-off valve. Open the drain valve and hot water
faucet(s) to vent heater while draining. Direct the flow of water to a drain
or bucket where it will not cause damage. Flush until water runs clear to
complete this operation. Close drain valve and reopen the supply line shut-off
valve. Close the hot water faucet(s) once all air has been bled from the
system (when water runs freely). Make certain that the heater is completely
full of water before restoring power.
Periodically (At least twice a year)
Check around the water heater and related plumbing for leaks. If the
combination temperature and pressure relief valve discharges periodically, or
water is leaking from around the heating elements, there may be a problem with
your water system. DO NOT ATTEMPT TO REPAIR LEAKS YOURSELF! Contact a
qualified service contractor for assistance.
Check the area around the water heater for flammable liquids or combustible
materials. If any are found, remove from the area.
Vacation (Extended shut-off periods)
During extended mild or warm weather periods when hot water will not be in
use, shut off the electric power to the tank. When hot water is needed again,
restore power to the water heater.
During extended cold weather periods when hot water will not be in use and
prone to freezing conditions, shut off electric power to the tank, close the
supply line shut-off valve, open the drain valve and drain the water heater to
a safe drainage location (as detailed previously). Once drained, close the
drain valve. When hot water is needed again, restore the water supply to the
tank. Once the tank is full, restore power.
WARNING
Water drained from the water heater may be scalding hot. Take care to avoid
scalding. Wear gloves and safety glasses, and direct water to a safe drainage
location. It is recommended to turn power off to the water heater and run
water at a hot water faucet until it cools BEFORE draining water from the
heater. Failure to comply with this warning could result in property damage,
severe personal injury, or death.
The maintenance activities described below are only to be performed by the
Installer / Qualified Service Provider. These maintenance items should be
performed during recommended annual service and any service calls.
- Ask the owner / user if there have been any issues with the water heater. Diagnose any heater issues and repair / replace parts as necessary.
- Check the water heater and related plumbing for leaks. Repair any that are found.
- Check the area around the water heater for flammable liquids or combustible materials. If any are found, remove from the area.
- Check the heating elements while the heater is in operation. If the elements are hissing / singing excessively, they may need to be cleaned. Inspect the elements and clean if necessary.
- Inspect the Temperature and Pressure (T&P) Relief Valve. See instructions below.
- Turn power supply off to the water heater. Open the drain valve and drain a few gallons of water from the tank to clear any hard water deposits. Once complete, close the drain valve and restore power to the water heater.
WARNING
T &P Relief Valve Maintenance Instructions:
- Annually: Certain naturally occuring mineral deposits may adhere to the valve, blocking waterways and rendering the valve inoperative. The T&P Relief Valve lever must be operated to ensure the waterways are clear. If waterways are clear, hot water will discharge from the valve. Take precautions to avoid personal injury and property damage from contact with hot water. Before operating lever, check to see that a discharge line is connected to the valve, directing the flow of hot water from the valve to a proper place of disposal.
- Replacement of the valve is required if no water flows when the lever is operated. Turn the water heater off until the valve is replaced.
- If water flows from the valve, drain a few gallons from the tank to ensure the water flows freely.
- At least once every three years: To ensure that the T&P valve has not been affected by corrosive water conditions and that the valve and discharge line have not been altered or tampered with illegally, relief valves should be inspected, and replaced, if necessary, by a licensed plumbing contractor or qualified service technician.
Failure to comply with these guidelines could result in failure of relief valve operation, and possibly result in substantial property damage, severe personal injury, or death.
Part 8 – Troubleshooting
*Table 5 – Troubleshooting – See Scald / Electric Shock Warnings and
Caution Statements, this Table.
WARNING
The risk of scald injury increases as you increase water temperature. Use a
water tempering or mixing valve and extreme caution when using hot water to
avoid scald injury. Consult codes for conformance. Failure to follow the
instructions in this warning statement could result in serious personal injury
or death from scalds.
Be sure to disconnect electrical power before performing service. Failure to
do so could result in electrical shock, property damage, serious personal
injury, or death.
CAUTION**
If draining of the water heater is necessary, open the T&P valve or a hot
water tap to prevent vacuum buildup in the tank and piping.
Problem | Reason | Remedy |
---|---|---|
No Hot Water | Manual disconnect switch turned off | Turn switch on |
1. Blown fuse or circuit breaker tripped
2. Shorted or improper wiring
3. Circuit overloaded
4. Grounded element or thermostat| 1. Replace fuse or reset breaker
2. Replace, repair, or rewire per detail
3. Provide adequate circuit to reduce load
4. Replace
Manual Reset High Limit (ECO) open
1. Thermostat(s) defective or out of calibration
2. ECO(s) defective or out of calibration
3. Heat build-up due to loose wires| Refer to Part 6, this manual.
1. Replace thermostat(s)
2. Lower thermostat setting or replace
3. Tighten wire connections
Improper wiring| Check and rewire per Wiring Detail
Not Enough Hot
Water| Heater undersized| Reduce rate of heater use
Defective element(s)| Check amperage, replace element if low
Miswired or defective thermostat causing only one element to work| Check
wiring or replace thermostat
Water Too Hot or
Not Hot Enough| Thermostat setting too high or low| Change setting as required
Thermostat out of calibration| Replace thermostat
Thermostat access panel(s) and/or insulation not in place| Inspect and replace
as needed
Thermostat(s) not resting tightly against mounting plate| Ensure that
retaining spring(s) or mounting screwshold thermostat(s) tightly to mounting
plates
T&P Valve
Discharges| Improperly seated valve| Open and close the handle to try to
reseat valve
Thermal expansion in closed water system| Install a thermal expansion tank
Damaged / defective valve| Replace relief valve
NOTE: DO NOT plug T&P valve under any circumstances
Water Leaks| Loose connection between inlet / outlet piping, relief valve,
and/or hex nut union on tank fittings| Tighten fittings
Damaged seal ring washer| Replace seal rings as required
Gasket around heating element(s)| Inspect and replace gasket if necessary
Hot Water Odor| High sulfate or mineral content in water supply| Drain and
flush water heater. Refill.
Bacteria in water supply| Check with local water treatment specialist or
utility to identify and address this problem.
Noisy Operation| Hard water scale built up on element(s)| *Remove and clean
*Table 5 – Troubleshooting – See Scald / Electric Shock Warnings and
Caution Statements, this Table.
WARNING
The risk of scald injury increases as you increase water temperature.
Use a water tempering or mixing valve and extreme caution when using hot water
to avoid scald injury. Consult codes for conformance.
Failure to follow the instructions in this warning statement could result in
serious personal injury or death from scalds.
Be sure to disconnect electrical power before performing service. Failure to
do so could result in electrical shock, property damage, serious personal
injury, or death.
CAUTION**
If draining of the water heater is necessary, open the T&P valve or a hot
water tap to prevent vacuum buildup in the tank and piping.
Part 9 – Replacement Parts
Figure 8 – Replacement Parts – Staged Operation
ITEM# | DESCRIPTION | PART # |
---|---|---|
1 | JUNCTION BOX COVER (w/SCREWS) | 6060P-983 |
2 | THERMOSTAT – UPPER | 6060P-1008 |
THERMOSTAT – UPPER (“U” MODELS ONLY) | 6060P-001 | |
3 | THERMOSTAT – LOWER | 6060P-1009 |
THERMOSTAT LOWER (“U” MODELS ONLY) | 6060P-002 | |
4 | THERMOSTAT PROTECTIVE COVER -UPPER | 6060P-994 |
THERMOSTAT PROTECTIVE COVER -UPPER (U-MODELS ONLY) | 6060P-634 | |
5 | THERMOSTAT PROTECTIVE COVER-LOWER | 6060P-952 |
THERMOSTAT PROTECTIVE COVER-LOWER (U-MODELS ONLY) | 6060P-636 | |
6 | ACCESS PANEL | 6060P-187 |
7 | SCREWS – ACCESS PANEL | 6075P-006 |
8 | MOUNTING BRACKET | 6060P-955 |
MOUNTING BRACKET (“U” models only) | 6060P-956 | |
9 | ELECTRIC ELEMENT – 3000W | 6060P-939 |
ELECTRIC ELEMENT – 4500W | 6060P-938 | |
ELECTRIC ELEMENT – 5500W | 6060P-937 | |
10 | DRAIN VALVE | 6070P-009 |
11 | DIP TUBE – 40 GAL | |
DIP TUBE – 52 GAL. | 6060P-1034 |
6060P-1035
12| NIPPLE/HEAT TRAP| 6060P-1038
13| TEMP/PRESSURE RELIEF VALVE| TP1000
14| JUNCTION BOX COVER W/ KNOCKOUTS (W/SCREWS)| 6060P-982
15| PROTECTIVE INSULATION| 6060P-965
PARTS FOR UNITS WITH BOLT-ON T-STAT BRACKETS ONLY-NOT SHOWN
16 | THERMOSTAT MOUNTING BRACKET-BOLT-ON | 6060P-633 |
---|---|---|
17 | SPACER | 6060P-979 |
18 | NUTS | 6060P-935 |
19 | ELEMENT PROTECTIVE COVER | 6060P-070 |
Two Element Residential Electric Water Heater
Limited Warranty
For Residential Use
Ariston warrants each Residential stainless steel electric water heater and
its components to be free from defects in materials and workmanship according
to the following terms, conditions, and time periods. UNLESS OTHERWISE NOTED
THESE WARRANTIES COMMENCE ON THE DATE OF INSTALLATION. This limited warranty
is only available to the original consumer purchaser (hereinafter “Owner”) of
the water heater, and is non-transferable.
WARRANTY PERIODS
Standard Residential Use Warranty | Parts | Tank |
---|
Water heater is used in a leasing or rental program or registered to a
business entity or corporation, or| One (1) Year| Ten (10) Years
Water heater is not registered online within ninety (90) days of the
installation date.
Extended Residential Use Warranty| Parts| Tank
Water heater is used in a single installation location and registered online
within ninety (90) days of the installation date.| Six (6) Years| Lifetime
NOTE: Any water heater used in a leasing or rental program or registered to a
business entity
or corporation IS EXCLUDED from an Extended Warranty and will be covered by
the Standard Residential Use Warranty detailed above.
COVERAGE
A. Extended Warranty – During the first six (6) years after the original date
of installation in the installation location, Ariston warrants that it will
repair or replace, at its option, any defective or malfunctioning component of
the water heater. Replacement components will be warranted for ninety (90)
days.
Standard Warranty – During the first year after the original date of
installation in the installation location, Ariston warrants that it will
repair or replace, at its option, any defective or malfunctioning component of
the water heater. Replacement components will be warranted for ninety (90)
days.
B. Should a defect or malfunction result in a leakage of water from the water
heater within the above-stated warranty periods due to defective material or
workmanship, malfunction, or failure to comply with the above warranty, with
such defect or malfunction having been verified by an authorized Ariston
representative, Ariston will repair or replace, at its option, the defective
or malfunctioning water heater. Replacements will be of the nearest comparable
model available at the time of replacement. The replacement water heater will
be warranted for the unexpired portion of the applicable warranty period of
the original water heater.
C. In the event of a leakage of water of a replacement water heater due to
defective material or workmanship, malfunction, or failure to comply with the
above warranty, Ariston reserves the right to refund to the Owner the
published wholesale price available at the date of manufacture of the original
water heater.
D. If government regulations, industry certification, or similar standards
require the replacement water heater or component(s) to have features not
found in the defective water heater or component(s), the Owner will be charged
the difference in price represented by those required features. If the Owner
pays the price difference for those required features and/or to upgrade the
size and/or other features available on a new replacement water heater or
component(s), the Owner will also receive a complete new limited warranty for
that replacement water heater or component(s).
E. If at the time of a request for service the Owner cannot provide a copy of
the original sales receipt or the warranty registration, the warranty period
for the water heater shall then be deemed to have commenced on the date of
manufacture of the water heater and NOT the date of installation of the water
heater, and be covered by the unexpired portion of the Standard Residential
Use Warranty detailed above.
F. This warranty extends only to water heaters utilized in heating
applications that have been properly installed by qualified professionals
based upon the manufacturer’s installation instructions.
G. It is expressly agreed between Ariston and the Owner that repair,
replacement, or refund are the exclusive remedies of the Owner.
OWNER RESPONSIBILITIES
The Owner or Qualified Installer / Service Technician must:
- Have a relief valve bearing the listing marks of the American Society of Mechanical Engineers (ASME) installed with the water heater assembly in accordance with federal, state, and local codes.
- Have a vacuum relief valve certified to ANSI Z21.22 – Relief Valves for Hot Water Supply Systems – installed with the water heater assembly in accordance with federal, state, and local codes and in installations prone to vacuum related damages.
- Maintain the water heater in accordance with the maintenance procedure listed in the manufacturer’s provided instructions. Preventive maintenance can help avoid any unnecessary breakdown of the water heater and keep it running at optimum efficiency.
- Maintain all related system components in good operating condition.
- Use the water heater in an open system, or in a closed system with a properly sized and installed thermal expansion tank.
- Use the water heater at water pressures not exceeding the working pressure shown on the rating plate.
- Keep the water heater free of damaging scale deposits.
- Make provisions so if the water heater or any component or connection thereto should leak, the resulting flow of water will not cause damage to the area in which it is installed.
WARRANTY EXCLUSIONS
This limited warranty will not cover:
- Any water heater purchased from an unauthorized dealer.
- Any water heater not installed by a qualified heating installer / service technician, or installations that do not conform to ANSI, CSA, and/or UL standards, as well as any applicable national or local building codes.
- Service trips to teach the Owner how to install, use, maintain, or to bring the water heater installation into compliance with local building codes and regulations.
- The workmanship of any installer. The manufacturer disclaims and does not assume any liability of any nature caused by improper installation, repair, or maintenance.
- Electricity or fuel costs, or increased or unrealized savings for same, for any reason whatsoever.
- Any water damage arising, directly or indirectly, from any defect in the water heater or component part(s) or from its use.
- Any incidental, consequential, special, or contingent damages or expenses arising, directly or indirectly, from any defect in the water heater or the use of the water heater.
- Failure to locate the water heater in an area where leakage of the tank or water line connections and the relief valve will not result in damage to the area adjacent to the water heater or lower floors of the structure, as well as failure to install the water heater in or with a properly sized drain pan routed to an approved drainage location.
- Any failed components of the system not manufactured by Ariston as part of the water heater.
- Water heaters repaired or altered without the prior written approval of Ariston.
- Damages, malfunctions, or failures resulting from improper installation, or failure to install the water heater in accordance with applicable building codes/ordinances or good plumbing and electrical trade practices; or failure to operate and maintain the water heater in accordance with the manufacturer’s provided instructions.
- Damages, malfunctions, or failures resulting from failure to operate the water heater at pressures not exceeding the working pressure shown on the rating label.
- Failure to operate the water heater in an open system, or in a closed system with a properly sized and installed thermal expansion tank.
- Failure or performance problems caused by improper sizing of the water heater, expansion device, piping, electric service voltage, wiring or fusing.
- Damages, malfunctions, or failures caused by improper wiring conversion.
- Damages, malfunctions, or failures resulting from vacuum conditions.
- Damages, malfunctions, or failures caused by operating the water heater with modified, altered, or unapproved components, or any component / attachment not supplied by Ariston.
- Damages, malfunctions, or failures caused by abuse, accident, fire, flood, freeze, lightning, electrochemical reaction, acts of God and the like.
- Tank failures (leaks) caused by operating the water heater in a corrosive or contaminated atmosphere.
- Damages, malfunctions, or failures caused by operating the water heater with an empty or partially empty tank (“dry firing”), or failures caused by operating the water heater when it is not supplied with potable water, free to circulate at all times.
- Failure of the heater due to the accumulation of solid materials or lime deposits.
- Any damage or failure resulting from improper water chemistry, or heating anything other than potable water. WATER CHEMISTRY REQUIREMENTS – Water pH between 6.5 and 8.5. Operating temperatures not exceeding 140F. Hardness less than 12 grains (200 mg/L). Chloride concentration less than 100 ppm (mg/L). TDS less than 500 ppm (mg/L).
- Any damages, malfunctions, or failures resulting from the use of dielectric unions.
- Production of noise, taste, odors, discoloration, or rusty water.
- Water heaters replaced for cosmetic reasons.
- Components of the water heater that are not defective, but must be replaced during the warranty period as a result of reasonable wear and tear.
- Components of the water heater that are subject to warranties, if any, given by their manufacturers; Ariston does not adopt these warranties.
- Damages, malfunctions, or failures resulting from the use of any attachment(s) not supplied by Ariston.
- Water heaters installed outside the fifty states (and the District of Columbia) of the United States of America and Canada.
- Water heaters moved from the original installation location.
- Water heaters that have had their rating labels removed.
ONLINE EXTENDED LIMITED WARRANTY REGISTRATION
To register for the Extended Limited Warranty, complete the form located on
the Ariston website at https://htp.secure.force.com/warrantywizard/ within
90 days of installation. The form must be completed in full with owner name,
email address, and phone number, the address where the unit is installed and
installation date, and unit model and serial numbers. Proof of purchase is
required, and may be an invoice for the product, or a bill from an installing
contractor that clearly documents the installation of the unit. To be valid,
proof of purchase must also include the unit serial number. Proof of purchase
may be typed or hand written. Submit the proof of purchase to Ariston via the
directions provided on the website.
PROCEDURES FOR WARRANTY SERVICE REQUESTS
Any claim for warranty assistance must be made promptly. Determine if the
water heater is “in-warranty” (that is, within the applicable warranty period)
by reviewing a copy of the original sales receipt or warranty registration.
The Owner must present a copy of the original sales receipt or warranty
registration for a warranty service request. If the water heater is “in-
warranty”, contact the retailer from whom the water heater was purchased (or
the installer) for assistance. Be prepared to provide the retailer or
installer with a copy of the original receipt, complete model and serial
numbers, and the date of installation of the water heater, in addition to an
explanation of the water heater problem. Warranty coverage is subject to
validation of “in-warranty” coverage by Ariston claims department personnel.
All alleged defective or malfunctioning components must be returned to Ariston
via the local distribution channels where the original purchase was made.
NOTE: Any components or water heaters returned to Ariston for warranty
analysis will become the property of Ariston and will not be returned, even if
credit is denied.
If all warranty conditions are satisfied, Ariston will provide replacement
components to the retailer.
For questions about the coverage of this warranty, please contact Ariston at
the following phone number:
1-774-417-6000.
SERVICE, LABOR AND SHIPPING COSTS
Except when specifically prohibited by the applicable state law, the Owner,
and not the Manufacturer, shall be liable for and shall pay for all charges
for labor or other expenses incurred in the removal, repair, or replacement of
the appliance or any component part(s) claimed to be defective or any expense
incurred to remedy any defect in the product. Such charges include, but are
not necessarily limited to:
- All freight, shipping, handling, and delivery costs of forwarding a new appliance or replacement part(s) to the owner.
- All costs necessary or incidental in removing the defective appliance or component part(s) and installing a new appliance or replacement part(s).
- All administrative fees incurred by the Owner, as well as material required to complete, and/or permits required for, installation of a new appliance or replacement part(s), and
- All costs necessary or incidental in returning the defective water heater or component part(s) to a location designated by the manufacturer.
LIMITATIONS OF YOUR Ariston WARRANTY AND REMEDIES THE FOREGOING WARRANTIES ARE
EXCLUSIVE AND ARE GIVEN AND ACCEPTED TO THE FURTHEST EXTENT UNDER APPLICABLE
LAW IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE AND ANY OBLIGATION, LIABILITY, RIGHT, CLAIM OR REMEDY IN
CONTRACT OR TORT, WHETHER OR NOT ARISING FROM Ariston’S NEGLIGENCE, ACTUAL OR
IMPUTED. THE REMEDIES OF THE OWNER SHALL BE LIMITED TO THOSE PROVIDED HEREIN
TO THE EXCLUSION OF ANY OTHER REMEDIES INCLUDING WITHOUT LIMITATION,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SAID INCIDENTAL AND CONSEQUENTIAL DAMAGES
INCLUDING, BUT NOT LIMITED TO, PROPERTY DAMAGE, LOST PROFIT OR DAMAGES ALLEGED
TO HAVE BEEN CAUSED BY ANY FAILURE OF Ariston TO MEET ANY OBLIGATION UNDER
THIS AGREEMENT INCLUDING THE OBLIGATION TO REPAIR AND REPLACE SET FORTH ABOVE.
NO AGREEMENT VARYING OR EXTENDING THE FOREGOING WARRANTIES, REMEDIES OR THIS
LIMITATION WILL BE BINDING UPON Ariston. UNLESS IN WRITING AND SIGNED BY A
DULY AUTHORIZED OFFICER OF Ariston. THE WARRANTIES STATED HEREIN ARE NOT
TRANSFERABLE AND SHALL BE FOR THE BENEFIT OF THE OWNER ONLY.
NO OTHER WARRANTIES
This warranty gives the Owner specific legal rights. The Owner may also have
other rights that vary from state to state. Some states do not allow the
exclusion or limitation of incidental or consequential damages so this
limitation or exclusion may not apply to the Owner.
These are the only written warranties applicable to the water heater
manufactured and sold by Ariston. Ariston neither assumes nor authorizes
anyone to assume for it any other obligation or liability in connection with
said water heaters.
Ariston reserves the right to change specifications or discontinue models
without notice.
Customer Installation Record Form
The following form should be completed by the qualified installer / service
technician for you to keep as a record of the installation in case of a
warranty claim. After reading the important notes at the bottom of the page,
please also sign this document.
Customer’s Name|
---|---
Date of Installation|
Installation Address|
Product Name / Serial Number(s)|
Comments|
Installer’s Code / Name|
Installers Phone Number|
Signed by Installer|
Signed by Customer|
Installation Notes|
IMPORTANT
Customer: Please only sign after the qualified installer / service technician
has fully reviewed the installation, safety, proper operation, and maintenance
of the system. If the system has any problems please call the qualified
installer / service technician. If you are unable to make contact, please
call your sales representative.