di-soric LI 104-12.5-1288-1340 I Measuring Light Grids Owner’s Manual
- June 13, 2024
- di-soric
Table of Contents
LI 104-12.5-1288-1340 I Measuring Light Grids
- With evaluation electronics LVE … / LVX … measuring and switching
- With evaluation electronics LVB … switching
- Beam evaluation horizontal or diagonal
- Compact design
- Aluminum housing
- Easy to install
- Transmitter
- Receiver
- Monitoring height H
- Profile length L
- Evaluation electronics
- Profile cross section
To be used with evaluation electronics LVE … / LVX … / LVB …
BN: brown
GN: green
GY: grey
WH: white
YE: yellow
Function
|
---|---
****|
Technical data (typ.)| +20°C, 24 V DC
---|---
Service voltage| 20 … 26 V DC (see evaluation electronics)
Assembly| Threaded bolt (3)
Profile cross section| 12 x 24 mm
Dimension| ■ A: 70 mm
■ B: 600 mm
■ X: 13,5 mm
■ Y: 38,5 mm
Profile length| 1.340 mm
Housing material| Aluminum (natural)
Protection class| III, operation on protective low voltage
Evaluation| absolute, percentage, Configurable via evaluation electronics
Evaluation electronics| external
Output function| Configurable via evaluation electronics
Switching output| Configurable via evaluation electronics, NO, NC
Light source| LED
Color| Infrared
Wavelength| 880 nm
Beam evaluation| via external evaluation electronics
Beam separation| 12,5 mm
Number of beams| 104
Monitoring height| 1.288 mm
Range| 250 … 6.000 mm (adjustable via evaluation electronics)
Measuring range| 1.288 mm
Ambient temperature during operation| -20 … +40 °C
Protection type| IP 54 (IP 65 optional)
Connection| Cable, 4,0 m (with plug connector, additional variants on request)
More information / accessories| https://www.di-soric.com/209593
https://di-soric.com/int-de/PM/209593
209593
LI 104-12.5-1288-1340 I
Light grids
di-soric GmbH & Co. KG . Steinbeisstraße 6 . DE-73660 Urbach . www.di-
soric.com
© di-soric . Right to change reserved . 13.08.2022 .
References