TempPro B65S Indoor Outdoor Thermometer Wireless Digital Hygrometer Sensor User Manual
- June 13, 2024
- TempPro
Table of Contents
- Introduction
- Hints and tips
- Specifications
- Components
- Indoor base station (receiver) features
- Outdoor remote sensor (transmitter) features
- Low battery Warning
- Power Management
- Synchronize Remote Sensors with The Base Station
- Place the Base Station and Remote Sensor
- Maximum & Minimum Recorded Temperature & Humidity
- FCC STATEMENT OF COMPLIANCE
- Declaration of Conformity
- Limited two-year warranty
- Purchasing additional remote sensors
- Customer service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**TempPro B65S Indoor Outdoor Thermometer Wireless Digital Hygrometer Sensor User Manual
**
Introduction
Congratulations on your purchase of the wireless Indoor/outdoor humidity and temperature monitor. You will now be able to know the outdoor/indoor temperature and humidity while sitting inside.
Hints and tips
If the receiver can’t connect to the transmitter, try as following:
- Repeat the synchronization process as described below.
- Relocate the base station or the remote unit until connection is established again.
- Signals from other electronic devices may cause interference. Place the base station and receiver away from these devices.
- If the base station is attached to a refrigerator or a metal object by magnet, the transmission may be shorter. Remove the base station from the refrigerator or the metal object or place the base station and remote sensor as close as possible.
Warnings
- Do not subject the unit to excessive force, shock, g\ dust, temperature or humidity.
- Do not immerse the unit in water. Do not remove any screws.
- Do not dispose this unit in a fire. IT MAY EXPLODE
- Keep unit away from children. The unit or parts of the unit might be a choking hazard.
- Dispose of the unit legally and recycle when possible.
Specifications
- Transmission frequency: 433 Mhz.
- Maximum transmit power: 8 mW.
- Transmission range up to 200 feet in open area. (range maybe shorter based on interference present).
- Indoor Temperature range: -4 °F ~ 158°F (-20 °C ~ 70°C).
- Outdoor Temperature range: -22°F ~ 158°F (-30 °C ~ 70°C).
- Humidity range: 10% ~ 9%
- Temperature tolerance: +/- 2.0 °F (+/- 1.1 °C).
- Humidity tolerance: +2% from 30% to 80%; 3% below 30% and above 80%.
- Power: 2 X AAA batteries 1.5V for base unit and 18650 lithium battery 3.7V for remote sensor.
Components
- One base station unit (Receiver).
- One remote sensor (Transmitter).
- USB charging cable.
# Although the remote sensor is designed to be rain- proof, it still must be always put in a dry place to avoid direct rainfall.
Indoor base station (receiver) features
-
Large LCD display
-
Remote Low Battery Icon
-
Outdoor temperature
-
Base Station Low Battery Icon
-
Indoor temperature
-
Four Touch Buttons
-
Indoor humidity
-
Magnet
-
Wall Mount
-
Stand
-
Battery compartment
-
LCD display: Displays the current outdoor temperature and indoor humidity/temperature.
-
Battery Compartment: Holds 2 AAA batteries to power the unit.
-
Tabletop and wall-mounted design.
-
Indoor Temperature range: -4°F~158°F (-20°C~70°C).
-
Humidity range: 10% ~ 99%.
-
Temperature display unit: °C and °F selectable.
-
Temperature Resolution: 0.1 °C/°F.
-
Humidity Resolution:1%.
-
Low battery indication.
-
Four touch buttons.
-
Back light.
Touch buttons
CHANNEL/SYNC: Press once to display the temperature readings from up to 3
outdoor remote sensors; Press and hold this button to enter the
synchronization mode.
MAX/MIN/CLEAR: Touch once to display the maximumor minimum temperature and humidity; Press and hold to clear the data history.
°F/°C/History: Press to select the temperature display in °C or °F; When the display shows the maximurm or minimum temperature and humidity. Touch this button once to set the maximum and minimum data record time interval between ALL TIME or 24 hours.
Note: Both ALL TIME and 24 hours keep records based on the last time you manually cleared the data history orinstalled a new battery.
: Touch once to turn on/off backlight. The backlight will automatically turn off after 15 seconds after the last button press.
Temperature & humidity trend
- indicates the temperature & humidity is in an increasing trend
- indicates the temperature & humidity is in a nochange trend.
- indicates the temperature & humidity is in a decreasing trend.
Outdoor remote sensor (transmitter) features
‘
-
LED
-
Reset
-
Wall Mount
-
Temperature Sensor
-
ON/OFF
-
Charging Socket
-
Channel
-
Built-in rechargeable lithium battery: Type 18650
-
Rain-proof and wall-mounted design
-
Outdoor Temperature range: -22°F~158°F(-30°C ~ 70°0)
-
Adapter input: AC100-240V 50/60Hz; Adapter output: DC5.0V 300mA
Buttons
To access CHANNEL SELECTOR and RESET buttons, you need to unscrew the cover.
CHANNEL Selector (1,2,3): Slide to set Channel 1,2 or 3.
RESET: Press once to reset the remote sensor.
:Press and hold for 2 seconds to turn ON/OFF the unit. (ON: Flash 1 time,
OFF: Flash
Low battery Warning
If the battery power for the base station or remote sensoris low, there will be low battery icon showing on the upper half area o the lower half area of the base station display. If the low battery icon for base station is displayed, please replace the batteries with new onesIf the low battery icon for remote sensor is displayed, please charge the remote sensor as soon as you can.
Power Management
Base station: open the battery compartment of the base station and insert two “AAA” batteries with correct polarity.
Remote sensor : A built-in rechargeable lithium battery is installed in the remote sensor. Although there could be some power in the rechargeable battery before the unit leaves the manufacturing facility, it is always advised to fully recharge the remote sensor before use by following the steps below:
- Note, the package does not INCLUDE a wall adapter. simply use any cellphone wall charger with USB socket to charge the battery. Connect the charging cable (provided in the package contents) into your wall adapter and take the other end of the plug and insert into the charging socket located on the back of the remote sensor;
- Plug the charger into a standard AC outlet;
- The red light on the remote sensor will light up;
- Charge it for at least 4 hours until the light changes from red to green which indicates charging is complete.
Synchronize Remote Sensors with The Base Station
- Place the remote sensor near the base station;
- Once the batteries are installed in the base station, the RF indicator (located on the upper left of the base station display) will flash for 3 minutes, indicating that the base station is in synchronization mode: waiting for remote sensors to be registered.
- Press and hold ON/OFF button on the back of the remote sensor for 2 seconds to turn on the remotesensor. Then wait for a moment until thetemperature of the remote sensor displays on thebase station which indicates that synchronizationis complete.
- If the synchronization is not successful after 3 minutes when the batteries are installed in the basestation and the RF indicator % no longer flashes,press and hold the CHANNEL/SYNC button on the left bottom of the base station LCD display for 3-4 seconds until the RF indicator flashes again indicating it’s back in synchronization mode;
- Set the CHANNEL selector (on the back of the remote sensor unit) to p]oosmon 1or2or3. The unit iis preset on Channel 1 and you can always leave it unchanged unless you have purchased more than 1 g remote sensor.
- If you have additional remote sensors, repeat the above steps to synchronize the additional remot\sensors z(up to 3 remote sensors can be registered with one base station). Please note the additionalsensors should be set to a different channel.
- If you have registered more than one sensor, press the CHANNEL/SYNC button on the base station to select the remote channel you want displayed permanently on the base station. Press CHANNEL/ SYNC button until you observe a circular arrow on the base station LCD display under the channel number, then the unit will auto-scroll, changing from channel to channel every 5 seconds.
Place the Base Station and Remote Sensor
- The indoor base station (receiver) should always be placed in a well ventilated indoor area and located away from vents, heating or cooling elements, direct sunlight, windows, doors, or any other openings.
- The remote sensor (transmitter) can be placed on a flat surface either indoors or outdoors. Make sure the sensor is within the wireless distance from the base station and with minimal obstructions. Although the remote sensor is designed to be rainproof, it still must be always put in a dry place to avoid direct rainfall.
- The base station and remote sensor can both be wall mounted.
Maximum & Minimum Recorded Temperature & Humidity
- Press MAX/MIN/Clear button once to display the highest indoor temperatures/humidity and outdoor temperatures recorded. MAX is shown on the display.
- Press MAX/MIN/Clear button again to display the lowest indoor temperatures/humidity and outdoor\ temperatures recorded. MIN is shown on the display.
- To clear and reset the max/min records, press and hold MAX/MIN/Clear for 3 seconds.
- When the MAX or MIN records are shown on the LCDdisplay, press ALL-TIME/24 button once to selectthe data record time interval between ALL TIME or 24 hours.
Note: Both ALL TIME and 24 hours keep records based on the last time you manually cleared the data history gy orinstalled a new battery.
FCC STATEMENT OF COMPLIANCE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation
Warning: Changes or modifications to this unit notexpressly approved by the party responsible forcompliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are residential installation. This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no@uarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio of television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/ TV technician for help.
Declaration of Conformity
Hereby, the manufacturer declares that this product complies with the basic requirements and applicablregulations of the Radio Equipment Directive 2014/53/EU, the EMC Directive 2014/30/EU. The complete declaration of conformity can be found at: https://itronicsmall.com/eu-declaration-of- conformity/
Disposal
Meaning of the “ Dustbin ” Symbol
- Protect our environment: do not dispose of electrical equipment in the domestic waste.
- Please return any electrical equipment that you will no longer use to the collection points provided for their disposal This helps avoid the potential effects of incorrect disposal on the environment and human health.
- This will contribute to the recycling and other forms of reutilisation of electrical and electronic equipment.
- Information concerning where the equipment can be disposed of can be obtained from your local authority.
CAUTION: Batteries/rechargeable batteries must not be disposed of with household waste!
- Take spent batteries to the appropriate collection point or to a dealer.
- Your town or local authority can provide information about public collection points.
This symbol can be found on batteries/rechargeable batteries which contain hazardous.
- Pb = contains lead
- Cd = contains cadmium
- Hg = contains mercury
- Li=contains lithium
Limited two-year warranty
TempPro warrants this product to be free of defects in parts, materials and workmanship for a period of two years, from date of purchase.
Should any repairs or servicing under this warranty be required, contact Customer Service by phone or email for instructions on how to pack and ship the product to TempPro.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Purchasing additional remote sensors
The model number of the remote sensor for this unit is jf ™*3.Additional sensors may be ordered directly from Amazon or TempPro by contacting our customer service listed below.
Customer service
Call or Text: +1(877)230-0040
Email: service@temppro.com
Hours: Weekdays 8:00 AM- 8:00 PM EST(USA)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>