Protoss PW11 RS485 To Wi-fi Converter User Manual
- June 13, 2024
- Protoss
Table of Contents
Protoss
-PW11 User Manual
Protoss-
PW11
RS485 to Wi-Fi
V 1.1
Overview of Characteristic
-
Support 802.11bgn Wireless Standard
-
Support STA/AP/AP+STA Mode
-
Support SmartLink V8 Smart Config (Provide APP)
-
Support TCP/UDP/MQTT/HTTP/WebSocket Protocol
-
Support Modbus TCP to RTU, Modbus Master Function
-
Support RS485 To WiFi Conversion
-
Support Webpage Easy Configuration or PC IOTService Tool
-
Support Security Protocol Such As TLS/AES/DES3
-
Support Heartbeat and Resister Packet Function
-
Support Webpage OTA Wireless Upgrade
-
Support Industrial Temperature: -40 to +70˚ C
-
Multiple Type of Different Power Input:
Protoss-PW11-H:100~240VAC@50~60Hz
Protoss-PW11-M:9~48VDC@1A -
Size: 102.03 x 64.95 x 27.50 mm (L x W x H) ,C45 rail installation
HISTORY
Ed. V1.0 02-10-2020 First Version
Ed. V1.1 03-18-2020 Update RS485 interfac
PRODUCT OVERVIEW
1.1. General Description
The Protoss-PW11 provides a RS485 interface to TCP/IP data transfer product.
The Protoss-PW11 integrate TCP/IP controller, memory, Wi-Fi transceiver, RS485
and integrates a fully developed TCP/IP network stack. Protoss-PW11 also
includes an embedded web server used to configure device.
The Protoss-PW11 using highly integrated hardware and software platform, it
has been optimized for all kinds of applications in the industrial control,
smart grid, personal medical application and remote control that have lower
data rates, and transmit or receive data on an infrequent basis.
1.2. Device Paremeters
Table1. Protoss-PW11 Technical Specifications
Item | Parameters |
---|
System Information
Processor/Frequency| 160MHz
Flash/SDRAM| 2MB/352KB
Operating System| mbed
Network Protocol
Network Protocol
| IP,TCP,UDP,DHCP,DNS,HTTP Server/Client,ARP, BOOTP, AutoIP, ICMP,Web socket,
Telnet, uPNP, NTP, Modbus TCP
Security Protocol| TLS v1.2 AES 128Bit DES3
Wi-Fi Interface
Standard| 802.11 b/g/n
Frequency| 2.412GHz-2.484GHz
Network Mode| STA/AP/STA+AP
Security| WEP/WPAPSK/WPA2PSK
Encryption| WEP64/WEP128/TKIP/ AES
Tx Power
| 802.11b: +18dBm (Max.)
802.11g: +16dBm (Max.)
802.11n: +15dBm (Max.)
Rx Sensitive
| 802.11b: -89dBm
802.11g: -81dBm
802.11n: -71dBm
Antenna| SMA Interface Antenna
Serial Port
Port Number| RS485
Data Bits| 7,8
Stop Bit| 1,2
---|---
Check Bit| None, Even, Odd
Baud Rate| TTL: 300 bps~230400 bps
Flow Control| No Flow Control
Software Xon/ Xoff flow control
Software
Web Pages| Http Web Configuration Customization of HTTP Web Pages
Configuration| Web CLI
XML import Telnet
IOTService PC Software
Basic Parameter
Size| 102.03 x 64.95 x 27.50 mm
Operating Temp.| -40 ~ 70°C
Storage Temp.| -40 ~ 85°C, 5 ~ 95% RH(no condensation)
Input Voltage| Protoss-PW11-H:100~240VAC@50~60Hz
Protoss-PW11-M:9~48VDC@1A
Working Current| ~200mA
Power| <700mW
1.3. Key Application
The Protoss-PW11 device connects serial device to Ethernet networks using the TCP/IP protocol:
- Remote equipment monitoring
- Asset tracking and telemetry
- Security Application
- Industrial sensors and controls
- Medical devices
- ATM machines
- Data collection devices
- Universal Power Supply (UPS) management units
- Telecommunications equipment
- Data display devices
- Handheld instruments
- Modems
- Time/attendance clocks and terminals
HARDWARE INTRODUCTION
The Protoss-PW11 unit is a complete solution for serial port device connecting
to network. This powerful device supports a reliable and proven operating
system stored in flash memory, an embedded web server, a full TCP/IP protocol
stack, and standards-based (AES) encryption.
Through Ethernet cable connect router with Protoss-PW11 serial server for data
transfer, which makes the data transformation very simple. 2.1. Interface Definition
Table2. Protoss-PW11-H Interface Definition
Pin | Description | Net Name | Signal Type | Comment |
---|---|---|---|---|
1 | AC Power Input | L | Power | 100~240VAC Input |
2 | AC Power Input | N | Power | |
5 | RS485_B- | IO | RS485 B- | |
6 | Signal GND | GND | Power | Used for RS485 GND, usually leave it unconnected |
7 | RS485_A+ | IO | RS485 A+ | |
ANT | Antenna | ANT | Wi-Fi 2.4G SMA Antenna | |
Reload | Restore to factory setting button | Reload | I | **Detailed functions |
see
Reset| Reset button| Reset| I| Hardware reset button
Net
|
Network status LED
|
Net
|
O
| Boot On: Boot OK.
0.1s Off -> 0.1s On: SmartLink Config Mode 0.3s Off -> 3s On: STA mode connect to router or AP mode being connected by other STA.
0.3s Off ->0.3s On: No Wi-Fi Connection
Active
|
UART Data Transfer
|
Active
|
O
| Off: No data transfer
0.3s Off -> 0.9s On: UART TX Output 0.3s Off -> 0.3s On: UART RX Receive
On: UART bidirection.
Power| Power LED| Power| O| On: Power input OK Off: Power input NG.
Link| Server connection LED| Link| O| On: netp Socket connection OK. Off: no
netp Socket connection.
Table3. Protoss-PW11-M Interface Definition
Pin | Description | Net Name | Signal Type | Comment |
---|---|---|---|---|
1 | DC Power Input | VCC+ | Power | 9~48VDC@1A Input |
2 | DC Power Input | GND- | Power | |
5 | RS485_B- | IO | RS485 B- | |
6 | Signal GND | GND | Power | Used for RS485 GND, usually leave it unconnected |
7 | RS485_A+ | IO | RS485 A+ | |
ANT | Antenna | ANT | Wi-Fi 2.4G SMA Antenna | |
Reload | Restore to factory setting button | Reload | I | **Detailed functions |
see
Reset| Reset button| Reset| I| Hardware reset button
Net
|
Network status LED
|
Net
|
O
| Boot On: Boot OK.
0.1s Off -> 0.1s On: SmartLink Config Mode 0.3s Off -> 3s On: STA mode connect to router or AP mode being connected by other STA.
0.3s Off ->0.3s On: No Wi-Fi Connection
Active
|
UART Data Transfer
|
Active
|
O
| Off: No data transfer
0.3s Off -> 0.9s On: UART TX Output 0.3s Off -> 0.3s On: UART RX Receive
On: UART bidirection.
Power| Power LED| Power| O| On: Power input OK Off: Power input NG.
Link| Server connection LED| Link| O| On: netp Socket connection OK. Off: no
netp Socket connection.
< Notes>
I — Input; O — Output; I/O: Digital I/O; Power—Power Supply nReload Pin (Button) function:
-
After module is powered up, short press this button (0.2< “Low” <1.5s) and loose to make the module go into “SmartLink“ config mode, waiting for APP to set password and other information. Download SmartLink V8 APP as following link:
http://www.hi-flying.com/download-center-1/applications-1/download-item- smartlink-v8 -
After module is powered up, long press this button (“Low” > 4s) and loose to make the module recover to factory setting.
2.2. RS485 Interface
RS485 use two wire links, A(DATA+), B(DATA-). Connect A(+) to A(+), B(-) to
B(-) for communication.
Suggest to connect GND together when interference is very severe.
The RS485 interface support maximum 32 RS485 device. The cable maximum length
is 1200 meters.
Need to add 120Ohm terminal resistor for over 300 meters.
2.3. Mechanical Size
The dimensions of Protoss-PW11 are defined as following picture (mm):
2.4. Product Installation
2.5. Order Information
Base on customer detailed requirement, Protoss-PW11 provide different
configuration version, Details as below:
NETWORK STRUCTURE
3.1. Wireless Network
Product can be set as a wireless STA and AP as well. And logically, it
supports two wireless interfaces, one is used as STA and the other is AP.
Other STA devices can join into the wireless network through AP interface. So
it can provide flexible networking method and network topology.
AP: Wireless access point which is the central joint. Usually, wireless router
is a AP, other STA devices can connect with AP to join the network.
STA: Wireless station which is terminal of a wireless network. Such as laptop
and pad etc.
3.1.1. AP Network
All the STA devices connect to the device AP transfer data to PLC device. Note
the STA devices can not communicate to each other due to PW11 does not support
router function, if need this function, use PW21/HF2211/HF2221
3.1.2. STA Wireless Network
Take the following picture as example. When router works in AP mode, product
connects to the user’ s devices by RS485 interface. In this topology, the
whole wireless network can be easily stretched.
3.1.3. AP+STA Wireless Network
Product can support AP+STA method. It can support AP and STA interface at the
same time.Shown as follow:
In this picture, open the AP+STA function and the STA interface can be
connected to the remote server by the router. Similarly, the AP interface can
also be used. Phone/PAD can be connected to the AP interface and to control
the serial devices or set itself.
Through AP+STA function, it is convenient to use Phone/PAD to monitor the
user’s devices and not change its original settings.
Notes that:
When the AP+STA function is opened, the STA interface needs to connect to
other router. Otherwise, STA interface will endlessly scan the router
information nearby. When it is scanning, it will bring bad effects to the AP
interface, like losing data etc.
AP and STA parts must set to the different sub-network for the product working
as APSTA mode.
Does not support Wi-Fi repeater function that means device works in AP+STA(STA
connects to router), PC connects to device AP, but can not access to internet
(If need this router function, use PW21/HF2211/HF2221)
3.1.4. IOTService Software
Open the IOTService after PC connect to the AP hotspot generated by product,
then config the parameter.
3.1.5. Webpage Configuration
Use PC to connect with product’s AP. Input the default IP(10.10.100.254,
default username and password: admin/admin) to login the webpage to configure
the parameter.
FUNCTION DESCRIPTION
Refer to “IOT_Device_Series_Software_Funtion” document for more detailed function.
APPENDIX A: CONTACT INFORMATION
Address: Room 1002,Building 1,No.3000,Longdong Avenue,Pudong New
Area,Shanghai,China,201203
Web: www.iotworkshop.com or www.hi-
flying.com
Contact:
Sales: sales@iotworkshop.com
Support: support@iotworkshop.com
Service: service@iotworkshop.com
Business: business@iotworkshop.com
For more information about IOTworkshop modules, applications, and solutions,
please visit our web site www.iotworkshop.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>