GEBERIT 970.647.00.0 Preda And Tamina Instruction Manual

June 13, 2024
GEBERIT

GEBERIT-logo

GEBERIT 970.647.00.0 Preda And Tamina

Product Information

The product is a Geberit urinal with integrated control and operates on a power supply. It is available in three models: Selva, Preda, and Tamina. The urinal features a ceramic design and includes components such as a urinal siphon, pressure reducer, and a magnet valve with a basket filter.


Product Usage Instructions

  1. Installation:
    • Place the urinal in the desired location, ensuring it is securely fixed to the wall.
    • Connect the urinal to the water supply using the provided siphon and pressure reducer.
    • Install the magnet valve with the basket filter to regulate water flow.
  2. Power Supply:
    • Ensure that the urinal is connected to a stable power supply using the appropriate cable.
    • Check the voltage requirements specified in the user manual before connecting.
  3. Operation:
    • To activate the urinal, approach it within the designated range.
    • The integrated control system will detect movement and automatically initiate flushing.
    • The magnet valve with the basket filter regulates water flow to ensure efficient flushing.
  4. Maintenance:
    • Regularly clean the urinal using mild detergents and non-abrasive cleaning materials.
    • Periodically check and clean the basket filter in the magnet valve to prevent clogging.
    • If any issues arise, refer to the troubleshooting section of the user manual or contact customer support for assistance.

Note: For detailed instructions regarding specific models (Selva, Preda, Tamina), refer to the respective sections in the user manual.

Safety

About this document

  • This document is intended for operators of Geberit Selva, Preda and Tamina urinals with integrated flush control, mains operation.
  • This document applies for the models of these urinals with Bluetooth® interface. The specification plate of these urinals are labelled with “IRUR-15-A” and the Geberit Connect logo.

Intended use
Urinals allow for urinating while standing up. These urinals are designed to be operated using a flush. Use for any other purpose is deemed improper.

Alert levels and symbols in this manual

Alert levels and symbols

ATTENTION
Indicates a hazard which, if not avoided, can lead to material damage.
Refers to important information.

Safety notes

  • Operation, care and maintenance may only be performed by the operator as described in this operation manual.
  • Repairs, conversions and additional installations may only be carried out by trained experts in sanitation applications.
  • Only trained experts in sanitation applications may replace current-carrying parts.
  • Only Geberit spare parts may be used.

Product description

Structure

Figure 1: Geberit Selva, Preda and Tamina urinals with integrated flush control, mains operation

  1. Spray head
  2. Urinal ceramic appliance
  3. Urinal trap
  4. Water pressure reducing valve
  5. Solenoid valve with basket filter
  6. Urinal flush control with power supply unit
  7. IR sensor

Technical data

Nominal voltage 110–240 V AC
Mains frequency 50–60 Hz
Mains connection Direct connection via system plug
Operating voltage 4.5 V DC
Power consumption < 0.5 W
Power consumption standby < 0.1 W
Flow pressure range 100–800 kPa

1–8 bar
Ambient temperature| 5–40 °C
Storage temperature| -20 – +70 °C
Flow rate at 1 bar with flow limiter| 0.18 l/s
Flush time, factory setting| 7 s
Flush time, adjustment range| 1–15 s
Wireless technology| Bluetooth® Low Energy1)
Frequency range| 2400–2483.5 MHz
Maximum output power| 4 dBm

The Bluetooth® brand and its logos are the property of Bluetooth SIG, Inc. and are used under license by Geberit.

Simplified EU Declaration of Conformity

  • Geberit International AG hereby declares that the radio equipment type for Geberit Preda, Selva and Tamina urinals with integrated flush control, mains, battery or generator operation complies with Directive 2014/53/EU.
  • The full text of the EU declaration of conformity is available at the following Internet address: https://doc.geberit.com/970892000.pdf

Retrofitting to flush operation
Geberit Selva, Preda and Tamina urinals for integrated flush control (art. no. 116.075.00.1, 116.085.00.1 and 116.142.00.1) are supplied without a urinal flush control. It is possible to retrofit the urinals to flush operation by installing a urinal flush control. Installation of the urinal flush control is described in the following documents:

  • Installation manual for Geberit Selva urinals (art. no. 970.645.00.0)
  • Installation manual for Geberit Preda urinals (art. no. 970.644.00.0)
  • Installation manual for Geberit Tamina urinals (art. no. 970.646.00.0)

Operation

Geberit Apps

  • Various Geberit apps are available for operation, settings and maintenance. The apps commu-nicate with the device via a Bluetooth® interface.
  • The Geberit apps are available free of charge for Android and iOS smartphones in the respective App Stores.

Establishing connection with device
Scan the QR code and follow the instructions on the landing page.https://gbrt.io/dsvFE04

Actuating the flush
The electronic flush actuation has infrared leg detection. The leg detection range starts approx. 50 cm in front of the urinal.

  1. Enter the detection range and remain there for at least 10 seconds.
  2. Leave the detection range.
  3. The flush will actuate.
  4. For testing purposes, the flush can also be actuated with a Geberit app.

Troubleshooting

Malfunction Cause Action
Incorrect flushes (too soon, too late, unwanted) Detection distance not set
correctly Optimise the detection distance. → See “Optimising the detection

distance”, page 18.
IR window is dirty or wet| Clean or dry the IR window.
IR window scratched| Contact a skilled person.
Water is running continuously into the urinal ceramic.| Software fault| Restart the urinal flush control. → See “Restarting the urinal flush control”, page 18.
Technical fault| Contact a skilled person.
Flushing out of the urinal ceramic is inadequate.| Flush time set incorrectly| Set flush time. → See “Setting the flush time”, page 18.
Flush volume is inadequate.| Basket filter in solenoid valve clogged| Clean the basket filter. → See “Cleaning or replacing the basket filter”, page 18.
No flush actuation| Network failure| Check the power supply.

Maintenance

Structure of Maintenance chapter
The accompanying illustration sequences must be followed while carrying out the instructions provided in this chapter. Each set of instructions refers to the accom-panying  illustration sequence.

Caring for and cleaning smooth surfaces
All smooth surfaces can be cleaned hygienically with water and a mild, liquid cleaning agent that is kind to the skin.

ATTENTION
Surface damage caused by aggressive and scouring cleaning agents

  • Never use cleaning agents that contain chlorine or which are acidic, abrasive or corrosive.

Activating cleaning mode
To clean the urinal ceramic and to clean or replace the urinal trap, the flush actuation can be suppressed for a few minutes.

  • Activate cleaning mode with the Geberit app, Geberit Service Handy or Geberit Clean Handy.

Result

  • ✓ The flush actuation is suppressed for 10 minutes.
  • ✓ Once these 10 minutes have elapsed, a flush is actuated.

Notes:

  • You can only activate cleaning mode 30 minutes after activating the power supply or setting the flush time.
  • The cleaning time of 10 minutes can be changed with a Geberit app (1–20 minutes).

Cleaning or replacing the spray head

  • Clean the cover for the spray head and the nozzle with a mild, liquid cleaning agent at least once a year.
  • Descale the nozzle with a commercially available descaling agent if necessary.
  • Replace the nozzle if it can no longer be completely cleaned and descaled.

Prerequisite
– Refer to figure sequence 3 , page 241 while carrying out the instructions.

  1. Demount the urinal flush control to disconnect the water supply. → See figure sequence 1 , page 239.

  2. Demount the cover for the spray head.

  3. Demount the nozzle.

  4. Clean the nozzle and rinse with water, or replace the nozzle (art. no. 243.333.00.1).

  5. Mount the nozzle.

  6. Mount the cover for the spray head.

  7. Mount the urinal flush control. → See figure sequence 2 , page 240.
    GEBERIT-970.647 \(10\)

Result
The urinal is ready for operation.

Replacing the urinal trap

For hygiene reasons, replace the urinal trap at least once a year.

Prerequisite

  • Cleaning mode is activated.
  • Refer to figure sequence 4 , page 242 while carrying out the instructions.
  1. Demount the cover for the urinal trap.
  2. Demount the urinal trap.
  3. Replace the urinal trap (art. no. 243.312.00.1) and the cover for the urinal trap (art. no. 243.314.00.1).
  4. Mount the urinal trap.
  5. Mount the cover for the urinal trap.

GEBERIT-970.647 \(11\)

Cleaning or replacing the basket filter

  • Clean the basket filter in the solenoid valve at least every 2 years or if the flush volume decreases.
  • Descale the basket filter with a commercially available descaling agent if necessary.
  • Replace the basket filter if it can no longer be completely cleaned and descaled.

Prerequisite
– Refer to figure sequence 5 , page 243 while carrying out the instructions.

  1. Demount the urinal flush control. → See figure sequence 1 , page 239.
  2. Demount the securing clamp.
  3. Demount the coupling.
  4. Remove the basket filter.
  5. Clean, descale or replace the basket filter.
  6. Install the basket filter.
  7. Mount the coupling and snap in the solenoid valve.
  8. Mount the securing clamp.
  9. Mount the urinal flush control. → See figure sequence 2 , page 240.

GEBERIT-970.647 \(12\)

Result
The urinal is ready for operation.

Setting the flush time
The flush time can be adjusted to suit the user’s needs using a Geberit app.

Optimising the detection distance

If flushes are actuated too soon, too late or unintentionally, you can optimise the detection distance of the IR sensor with a Geberit app.

Restarting the urinal flush control

  • Disconnect the mains voltage for approximately 30 seconds.
  • ✓ If necessary, switch the fuse in the electrical distributor off and on again.

Result
The urinal flush control restarts.

Disposal

Constituents
This product meets the requirements of Directive 2011/65/EU (RoHS) (restriction of the use of certain hazardous substances in electrical and electronic equipment).

Disposal of waste electrical and electronic equipment

  • The symbol of the crossed-out wheeled bin means that waste electrical and electronic equipment (WEEE) must be disposed of separately and not with other non-recyclable waste.
  • End users are legally obliged to return old equipment to public waste disposal authorities, distributors, or Geberit for proper disposal. Many distributors of electrical and electronic equipment are obliged to take back WEEE free of charge. Contact the responsible sales or service company to return the WEEE to Geberit.
  • Used batteries and accumulators that are not enclosed within the old equipment, as well as lamps that can be removed from the old equipment in a non-destructive manner, must be separated from the old equipment before being handed over to a disposal point.
  • If personal data is stored on the old equipment, end users themselves are responsible for deleting it before handing it over to a disposal point.

Geberit International AG Schachenstrasse 77, CH-8645 Jona documentation@geberit.com www.geberit.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GEBERIT User Manuals

Related Manuals