STAUDATE HIRSCH SH-3.170 Battery Charger Instruction Manual
- June 13, 2024
- STAUDATE HIRSCH
Table of Contents
- Intended use
- Delivery content
- Safety instructions
- Operation and display elements
- Description of the operating modes
- Charging the battery
- Charging curves
- Technical data
- Environmental protection note
- Dimensioning SH-3.170
- Customers Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
STAUDATE HIRSCH SH-3.170 Battery Charger
Intended use
The Battery Charger SH-3.170 is suitable for charging 6 V and 12 V lead batteries as well as 12 V lithium batteries (LiFePO4) with integrated battery management system (BMS). It was optimised for maintaining car and motorcycle batteries. Any other use than described before may damage this product. In addition, improper use may result in serious hazards, such as short-circuit, fire, electrical shock etc.
Delivery content
- Battery Charger SH-3.170
- Adapter cable with battery clamps
- Adapter cable with eyelet rings
- Instruction manual in DE, GB
Safety instructions
The following safety notes and hazard warnings serve for the protection of both the device and your health. So please read the following points thoroughly.
General
- For safety and technical approval reasons (CE), any unauthorized conversion and/or modification of the product is inadmissible.
- The charger may only be operated on mains voltage of 100 – 240 V AC at 50/60 Hz.
- The product is no toy. It should be kept away of children.
- The product must only be set up, operated and stored in a place which is out of the reach of children. Danger of life!
- The product is only suitable for charging 6 V and 12 V lead batteries as well as 12 V lithium batteries (LiFePO4) with integrated BMS. Never try to charge other rechargeable or non-rechargeable batteries (e.g. NiCd, NiMH, LiPo)! Fire and explosion hazard!
- Maintenance, installation or repair works may only be performed by an expert/qualified workshop. Use only original spare parts for repair work. The use of any other spare parts may lead to serious damage to property and personal injury!
- Do not leave packing materials unattended. It could become a hazardous toy for children!
- If you recognise damages, stop using the charger. Bring the product to a qualified workshop or dispose of it in an environmentally compatible manner.
Operation
- The use of the product under unfavourable environmental conditions must be avoided under all circumstances. Unfavourable environmental conditions include: ambient temperatures above 40 °C, flammable gases, solvents, vapours, dust and relative humidity in excess of 80 %.
- The charger may not be operated in the presence of flammable materials or gases.
- Ensure proper ventilation during the operational phase, never cover the charger.
- Never charge lead-acid batteries in containers or in poorly ventilated rooms. Charging lead-acid batteries may lead to the production of explosive gases!
- Keep charger and rechargeable battery away from ignition sources or open fire, do not smoke while using charger and rechargeable battery! Explosion hazard!
- Never start the device immediately after having taken it from a cold into a warm room. Condensation water may be generated leading not only to malfunctioning, but there is also a risk of perilous electric shock!
Notes on the rechargeable battery
-
Please observe all safety and charging information of the battery manufacturer.
-
Please remember to always disconnect the ground connection from the rechargeable battery first and only then the positive terminal.
-
Observe correct polarity when connecting a rechargeable battery to the charger (red terminal = plus/+, black terminal = minus/-).
-
Lead-acid batteries contain aggressive corrosive acids. Avoid eye and skin contact with liquids from the lead-acid battery! Wash the parts of the skin affected thoroughly with water and soap. If acid enters the eye, immediately flood the eye with running, clear and cool water!
Then seek medical help immediately! -
Never short-circuit rechargeable batteries or toss them into fire.
Fire and explosion hazard! -
Never disassemble your battery!
In case of improper handling or non-observance of these operating instructions or the safety notes stated herein, the warrant/guarantee shall lapse. We do not assume liability for any personal injury, damage to property or subsequent damage that can be attributed to this.
Operation and display elements
The Battery Charger SH-3.170 is equipped with a clear operation and display panel. The LEDs inform you about the chosen operating mode, the charging status of the rechargeable battery as well as a defective, short-circuited or reverse-poled rechargeable battery at any time.
-
Fault indicator (battery defective, short circuit, voltage reversal)
-
6 V Lead mode
-
Mode selection
-
12 V Lead mode
12 V Lithium mode -
Charging status indicator
Description of the operating modes
6 V Lead mode
The 6 V Lead mode is suitable for charging rechargeable 6 V lead batteries (please observe the information of the manufacturer of the battery). Continue to press the MODE button (3) until LED (2) flashes. After approx. 2 seconds the LED is constantly on and the charging procedure starts. The charging current is 2 A. The final charge voltage is 7.2 V. The charging status is indicated by LED (5). If the battery is full, the LED is constantly on and the battery charger automatically switches into Floating phase.
12 V Lead mode
The 12 V Lead mode is suitable for charging rechargeable 12 V lead batteries (please observe the information of the manufacturer of the battery). Continue to press the MODE button (3) until LED (4) flashes. After approx. 2 seconds the LED is constantly on and the charging procedure starts. The charging current is 2 A. The final charge voltage is 14.4 V. The charging status is indicated by LED (5). If the battery is full, the LED is constantly on and the battery charger automatically switches into Floating phase.
12 V Lithium mode
The 12 V Lithium mode is suitable for charging rechargeable 12 V LiFePO4 batteries with integrated battery management system (please observe the information of the manufacturer of the battery). Continue to press the MODE button (3) until LEDs (2) and (4) flash. After approx. 2 seconds, the LEDs are constantly on and the charging procedure starts. The charging current is 2 A. The final charging voltage is 14.4 V. The charging status is indicated by LED (5). If the battery is full, the LED is constantly on and the battery charger automatically switches into Floating phase.
Regeneration mode
If a deep discharged rechargeable battery is connected to the charger, the regeneration mode is the first mode to start. Low charging currents are used to try and bring the deep discharged rechargeable battery to a normal battery voltage again. When the battery reaches a normal voltage, the charger will continue charging using the regular process.
Defective, short-circuited or reverse-poled rechargeable batteries
The charger recognises defective rechargeable batteries, a short circuit or a battery which has been connected with wrong polarity automatically. In this case the selected charging programme will not be started. LED (1) is on.
The battery charger has an Auto-Memory-Function. Following a supply voltage failure, it ensures that the device will automatically return to the previously selected mode after power is restarted.
Charging the battery
-
First ensure that it is a lead battery with a voltage of 6 V resp. 12 V or a lithium battery (LiFePO4) with BMS with a voltage of 12 V. Rechargeable batteries with other voltages cannot be charged!
-
Disconnect all consumers from the rechargeable battery.
-
If the rechargeable battery is built into a vehicle, switch off the ignition and all consumers.
Please strictly observe any and all information and safety instructions of the vehicle on how the rechargeable vehicle battery needs to be charged. Modern vehicles are equipped with sensitive electronic components and control units which will be damaged when handled improperly! -
First, connect the charger to the power supply (100 – 240 V AC, 50/60 Hz).
-
Then, you may select from various functions by pressing the MODE button (3). Please strictly observe the information of the manufacturer of the rechargeable battery concerning permissible final charging voltage and maximum charging current when selecting the correct operating mode.
-
Connect the charger to the rechargeable battery observing correct polarity. Short-circuited, reverse-poled and defective rechargeable batteries are indicated by LED (1).
-
After charging, disconnect the battery charger from the power supply.
-
Then remove the terminal from the minus pole of the rechargeable battery and then from the plus pole.
Charging curves
Technical data
Input
Operation voltage| 100 – 240 V AC / 50/60 Hz
Input current| max. 0.62 A
Power consumption| max. 45 VA
Output
Suitable battery voltage| 6 V, 12 V
Charging current| max. 2.0 A ± 10 %
Rechargeable battery type| 6 V and 12 V lead batteries Acid, Gel, AGM 12 V
LiFePO4 batteries
Cut-off voltage| 7.2 V ± 0.25 V 6 V Lead mode 14.4 V ± 0.25 V 12 V Lead mode
14.4 V ± 0.25 V 12 V Li mode
General
Reverse current| < 0.5 mA
Protection type| IP 20
Cable length| 1.70 m (mains cable) 1.60 m (connection cable incl. adapter)
Dimensions| 110 x 70 x 40 mm
Weight| 280 g (without accessories) 380 g (with accessories
Environmental protection note
At the end of its useful life, this product may not be disposed of together with normal household waste, but has to be dropped off at a collection center for the recycling of electrical and electronic devices. This is indicated by the symbol on the product, on the instruction manual or on the packaging.
The materials of which this product is made are recyclable pursuant to their labelling. With the reuse, the recycling of the materials or other forms of scrap usage, you are making an important contribution to the protection of the environment. Please ask your local authorities for the appropriate disposal center.
Technical specifications subject to change. We assume no liability for
typographical errors.
V02_03/2022.
You can request the declaration of conformity for this product from the IVT
service-team.
IVT Innovative Versorgungstechnik GmbH, Dienhof 14, D-92242 Hirschau
Tel. +49 9622-719910, Fax +49 9622-7199120, info@ivt-hirschau.de, www.ivt-hirschau.de
Dimensioning SH-3.170
The adapter cables may also be ordered separately:
-
Adapter cable with battery clamps (Order no. 911000.K)
-
Adapter cable with eyelet rings (Order no. 911000.O)
-
Adapter cable with 12 V plug (Order no. 911000.Kfz)
-
3-piece Adapter Cable Set (Order no. 911000.A)
Customers Support
Staudte Hirsch
Designed in Germany.
Powered by IVT.
IVT Innovative Versorgungstechnik GmbH
Dienhof 14
D-92242 Hirschau
fon +49 (0) 9622 71991-0
fax +49 (0) 9622 71991-20
info@ivt-hirschau.de
www.ivt-hirschau.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>