UNI-T UTi260E Professional Thermal Imager User Manual
- June 13, 2024
- UNI-T
Table of Contents
- UNI-T UTi260E Professional Thermal Imager
- PREFACE
- LIMITED WARRANTY AND LIABILITY
- Technical Specifications
- Product Structure
- LCD Indicators/Icons
- Power on/off
- Menus
- Markup
- Image
- Palette
- Measure
- Isotherm
- System
- Maintenance
- Safety Instructions
- FCC Compliance statement
- Common Emissivity
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UNI-T UTi260E Professional Thermal Imager
PREFACE
Thank you for purchasing the new UTi260E Professional Thermal Imager. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly. This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by any reason or speculation. As some areas or countries do not allow limitations on implied warranties and incidental or subsequent damage, the above limitation of liability and stipulation may not apply to you.
Technical Specifications
Product Structure
LCD Indicators/Icons
- Display size: 640×480
- Display resolution: 256 (vertical) × 192 (horizontal)
Power on/off
Long press the power button for 5s to turn on/off the thermal imager (it needs 30 minutes warm-up time when the device is just turned on or not used for a long time, or the measurement environment changes). When the battery is low, a low battery indicator will show on the LCD, which means the thermal imager should be turned off and the battery should be charged. When the thermal imager is in low battery status for a long time, the device will automatically shut down.
Menus
Main Menu Configuration Options
In the main interface:
- Press the SET button to open the main menu.
- Press the left/right button to step through submenus.
- Press the SET button to open the selected submenu.
- Press the left/right button to step through setting items in the submenu.
- Press the SET button to confirm the selected setting item.
- Press the return button to return to the previous interface and save the setting.
- Press the return button again to return to the main interface.
Main Menu
Submenu
Markup
In the main interface, press the SET button to open the main menu. Press the left/right button to select “Markup”. Press the SET button again to open the submenu of “Markup”. In the submenu, press the left/right button to select a submenu option. (For example: press the SET button to perform the selected function “Center”, and a center point marker will show on the middle of the screen. Press the button again to exit.)
Image
In the main interface, press the SET button to open the main menu. Press the left/right button to select “Image”. Press the SET button again to open the submenu of “Image”. In the submenu, press the left/right button to select a submenu option. (For example: press the SET button to perform the selected function “Fusion” and the image will switch to the fusion mode.) In the fusion mode, press the left/right button to adjust the mix proportion, and up/down button to adjust the mix distance. In the PIP mode, press the left/right button to move the position or stretch the size of PIP. As for the QR function, users can manually input the QR code or scan the QR code. Select “cancel” to return to the main interface.
Palette
In the main interface, press the SET button to open the main menu. Press the left/right button to select “Palette. Press the SET button again to open the submenu of “Palette”. Press the left/right button to step through seven optional palettes: iron, Rainbow, whitehot, redhot, blackhot, lava, Rain.HC.
Measure
In the main interface, press the SET button to open the main menu. Press the left/right button to select “Measure”. Press the SET button again to open the submenu of “Measure”. In the submenu, press the left/right button to select an analysis object (Point, Line, Rect., Circle). Press the SET button to add the selected object. The submenu also includes three other functions: choose (this function can only be used if an analysis object is added), clear. preset.
After adding an analysis object, a submenu will appear. The optional functions in the submenu are choose, move, stretch (this function cannot be applied to point objects), diff (point objects can only be compared with point objects; the comparison information will be displayed on the right side), delete (delete the selected object). The temperature information of the added object will be displayed on the left. When a line object is selected, its temperature change graph will be displayed in the lower left corner.
Press the “SET” button to perform the “clear” function, and all the analysis objects in the current interface will be cleared. When there is an analysis object, press the “SET button”to perform the “preset” function, and a box “Save tool” will pop up. Select “OK” to save the analysis object. The preset tool can be used directly next time. If there is no temperature measurement and analysis object on the main page, press the “SET” button to select a preset tool, and a prompt box of “Read tool” will pop up. Select Confirm, and the preset tool saved last time will be added to the main page. When there is no analysis object in the main interface, press the “SET” button to perform the “preset” function, and a box “Read tool” will pop up. Select “OK” and the preset tool will be added to the interface.
Note: The maximum number of point objects that can be added is 5 (line: 1; Rect.: 3; circle: 3). The total number of analysis objects added cannot exceed 6. When it exceeds 6, a box “Outnumber” will pop up.
Isotherm
In the main interface, press the SET button to open the main menu. Press the left/right button to select “Isotherm”. Press the SET button again to open the submenu of “Isotherm”. The options in the submenu are: Auto, Ratio, Below, Above, Section, Manual.
System
Press the SET button to enter the submenu. Press the up/down button to select a setting item, and press the SET button to enter the interface of this item.
Camera Model
In the setting interface, select “camera model” and press the SET button to
enter the submenu. Press the up/down button to select Single Shot/Time-lapse.
In the Time-lapse mode, press the up/down button to adjust the Time-lapse
interval (10s-1000s).
Units
In the setting interface, select *units” and press the SET button to enter the
submenu. Press the up/down button to select temperature/distance. When
selecting temperature, press the up/down button to change the units (F /K/°C).
The distance unit cannot be changed.
Parameter
- In the setting interface, select “parameter” and press the SET button to enter the submenu.
- Press the up/down button to select Emissivity/Ambient Temp./Reflected Temp./Relative
- Humidity/ObjectDistance/Temperature Scale.Press the SET button to select the parameter to be modified, and press the up/down button to adjust the parameter value.
- When setting the object distance, press the SET button to enter its submenu, and then press the SET button and the up/down button to modify the parameter.
- Low temperature:- 20°C~150°C
- High temperature: 0°C-550°C
- Note: lt takes about 20S to switch mode.
- Please wait until it is stable and take the next action.
- Please refer to emissivity table on page 40;
- If you are not sure which value to use, use the following default values
- Emissivity 0.95
- Ambient Temp. 25°C
- Reflected Temp. 25°C
- Relative Humiditv 55%RH
- ObjectDistance 0.25m
Note: Emissivity and reflection temperature are the two most important
parameters to set correctly. If in doubt, use the default values.
HI/LO Alert
In the setting interface, select “HI/LO Alert ” and press the SET button to
enter the submenu. Press the up/down button to select HI/LO/LED Alert. When
setting HI/LO, press the up/down button to select H_ value O value press the
SET button to modifv and press the undown button to select HI value/LO value,
press the SET button to modify, and press the up/down button to adjust the
value (-20°C 550°C).
When the measured temperature exceeds the HI value, a red triangle will pop up. When the measured temperature is lower than the LO value, a green inverted triangle will pop up.
QR CODE
In the setting interface, select “QR code and press the SET button to enter
the submenu.Press the up/down button to select a QR code. Press the SET button
to change the code name or reset the code.
Language
In the setting interface, select “Language” and press the up/down button to
select Simplified Chinese/English
Date & Time
In the setting interface, select “Date & Time” and press the SET button to
enter the submenu.Press the SET button to modify Time format/Date/Time, and
press the up/down button to adjust the value.
Wi-Fi
In the setting interface, select “Wi-Fi” and press the SET button to enter the
submenu. Pressthe SET button to turn on the LionScripts, press the down button
to select the ID and password, and press the SET button to confirm.
USB mode
In the setting interface, select “USB mode and press the SET button to enter
the submenu. Press the up/down button to select USB storage/USB projection,
and press the SET button to confirm.
Brightness
In the setting interface, select “Brightness” and press the up/down button to
adjust the brightness (1-100).
Auto power off
In the setting interface, select “Auto power off” and press the up/down button
to select Off/5min/10min/20min/30min/45min/60min/90min.
Factory Reset
In the setting interface, select “Factory reset” and press the SET button. A
box “Factory reset?” will pop up. Select “Yes”, the device will automatically
shut down. After turning on again, the device will restore the factory
settings.
About
In the setting interface, select “About” and press the SET button to enter the
submenu. The product information including product, Thermal Resolution, HWV,
SYSV and SD can beViewed
Image Viewing
- In the main interface, press the image viewing button to enter the multimedia browsing interface. Press the up/down button to select all photos or other folders, and press the
- SET button to open the selected folder. Press the up/down/left/right button to select the image to be viewed, and press the SET button to view this image. Press the left/right button to switch between images.
- When viewing an image, press the SET button to open the submenu of this image. The functions in this submenu are:
- Message: create date, ModifiedDate, Emissivity, HVGA, Ambient Temp., Relative Humidity,
- ReflectiveDistance, QR code, remarks.
- Notes: The added notes will show in the photo message.
- Redact: markup, image, palette, measure, Isotherm.
- QR code : Users can add an existing QR code for image classification, or can delete the QR code of the current image or add a new QR code Delete.
- Note: In the redact interface, after editing a photo, press the SET button and then the up button to select “restore”. Press the SET button again to restore the photo to its original state. Press the return button after editing, and a box “save/exit/esc” will pop up. Select Exit to exit the editing interface. Select Save and a box “Cover?” will pop up. Select Cover, the original image will be changed and saved. Select New, the original image will not be changed and a new image will be saved
After adding the QR code, press the return button, and a prompt “Save and
exit” will pop up. Choose Confirm to save the added QR code. Choose Cancel to
exit the QR code editing page without saving. The QR code added here will not
be saved to the existing QR code category. If users want to modify the
existing QR code, they need to change it in the settings
Buttons
In the main interface, press the up button to zoom in. The magnification is
displayed in the upper right corner of the screen, and it will step through
1X, 2X, 4X, and 1X. In the main interface, press the left/right button to
adjust the degree of fusion. The optional degrees are 0%, 25%, 50%, 75%, and
100%.
SD Card
This device supports Micro SD card to store images. To avoid affecting the
operating speed of the device, please copy the backup data regularly and clean
up the SD card in time. To avoid causing abnormal data on the SD card, do not
insert or remove the SD card repeatedly. If the SD card is removed in the
image viewing interface, a box “SD lost” will pop up
Maintenance
Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the outer shell, lens or window.
Safety Instructions
- In order to ensure the accuracy, please read the instructions carefully. Please use this product in accordance with the manual; otherwise the free warranty will not be carried out if the product is damaged. Please do not use this device in flammable, explosive, steamy, humid or corrosive environments. Please do not continue to use the device when it is damaged, broken or corrected, so as to avoid incorrect test results. Please refer to the emissivity information to confirm the actual temperature; otherwise the measured temperature will be inaccurate.
- Do not aim the lens at a strong or hot light source, such as the sun and other high-temperature objects, so as to avoid damage to the lens or thermal imaging detector.
- Do not use the product in extremely hot, cold, dusty or high humidity environments. For detailed temperature and humidity requirements, please refer to the parameter table.
- The product can be charged with a USB cable. However, in order to improve the charging efficiency, it is recommended to pull out the battery pack and charge the battery pack separately.
FCC Compliance statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Common Emissivity
CONTACT