ROGER Serie BE20 Swing Gates Automations Instruction Manual

June 13, 2024
ROGER

ROGER Serie BE20 Swing Gates Automations

Product Information

Product Name: Automazione per cancelli a battente (Swing gate automation)
Model: Serie BE20
Manufacturer: Roger Technology
Manufacturer Address: Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV)

Date of Declaration: 03-06-2015

Standards and Technical Requirements Applied: EN 61000-6-3, EN 61000-6-2, EN 60335-1, EN 60335-2-103

Product Usage Instructions

  1. Before installation, perform the following preliminary checks:
    • Ensure that the gate structure is robust.
    • Ensure that the hinges are well lubricated and the movement is smooth and regular throughout its range without friction.
    • Always provide a mechanical stop in both the open and closed positions, securely fixed to the ground. The stop should have an elastic element (e.g., rubber) to cushion the gate’s arrival at the stop.

Swing gates automation
INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

General safety precautions

Failure to respect the information given in this manual may cause personal injury or damage to the device.
This installation manual is intended for qualified personnel only.

ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other the intended usage indicated in this manual.
Installation, electrical connections and adjustments must be performed by qualified personnel,in accordance with best practices and in compliance with applicable regulations.
Read the instructions carefully before installing the product. Bad installation could be dangerous.
Before installing the product, make sure it is in perfect condition: if in doubt, do not use the equipment and contact qualified personnel only.
Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard.
Before installing the motorisation device, make all the necessary structural modifications to create safety clearance and to guard or isolate all the crushing,shearing, trapping and general hazardous areas.
Make sure the existing structure is up to standard in terms of strength and stability.

ROGER TECHNOLOGY is not responsible for failure to observe Good Working Methods when building the frames to be motorised, or for any deformation during use.

The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good Working
Methods, installation premises, system operating logic and the forces developed by the motorised door or gate.
The safety devices must protect against crushing, cutting, trapping and general danger areas of the motorised door or gate.
ROGER TECHNOLOGY declines all responsibility if component parts not compatible with safe and correct operation are fitted.
Display the signs required by law to identify hazardous areas.

Each installation must bear a visible indication of the data identifying the motorised door or gate.
An omnipolar disconnection switch with a contact opening distance of at least 3mm must be fitted on the mains supply.
Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A and overcurrent cutout
upstream of the electrical system in accordance with best practices and in compliance with applicable regulations.
When requested, connect the automation to an effective earthing system that complies with current safety standards.
During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts.
The electronic parts must be handled using earthed antistatic conductive arms.

Only use original spare parts for repairing or replacing products.
The installer must supply all information concerning the automatic, manual and emergency operation of the motorised door or gate, and must provide the user with the operating instructions.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as they are a potential source of danger.
Dispose of and recycle the packing components in accordance with the standards in force.
These instruction must be kept and forwarded to all possible future user of the system.

Declaration of Conformity
I the undersigned, as acting legal representative of the manufacturer:
Roger Technology – Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV) hereby DECLARE that the appliance described hereafter:
Description: Swing gate automation
Model: serie BE20

Is conformant with the legal requisites of the following directives:

  • Directive 2004/108/EC (EMC Directive) and subsequent amendments;
  • Directive 2006/95/EC (Low Voltage Directive) and subsequent amendments; and that all the standards and/or technical requirements indicated as follows have been applied:
    • EN 61000-6-3
    • EN 61000-6-2
    • EN 60335-1
    • EN 60335-2-103

Last two figures of year in which marking was applied 15.
Place: Mogliano V.to Date: 03-06-2015 Signature

STANDARD INSTALLATION BE20 RANGE

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(2\)

DESCRIPTION

1: Automatism BE20
2: Control unit
3: Key selector
4: Flashing light
5: Antenna
6: External photocell
7: Internal photocell
8: Gate open mechanical stop

DIMENSIONS

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(3\)

MODELS AND SPECIFICATIONS

BE20/200
Low voltage irreversible electromechanical Brushless gear motor for heavy duty use, with native encoder onboard and ideal for swing leaf gates with leaf lengths up to 2,8 m

BE20/200/HS
Low voltage irreversible electromechanical Brushless HIGH SPEED gear motor for heavy duty use, with native encoder onboard and ideal for swing leaf gates with leaf lengths up to 2,5 m.

BE20/400
Low voltage irreversible electromechanical Brushless gear motor for heavy duty use, with native encoder onboard and ideal for swing leaf gates with leaf lengths up to 4 m.

TECHNICAL DATA

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(14\)

WARNING
According to the legislation in force and for safety purposes, if the gate length exceeds 2.5 m with normal wings, 2 m with full wings and if its height exceeds 2 m, it is recommended to use an electric lock.

WORKING DIAGRAM

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(5\)

NOTE.  with blind door and installation in a suction cup area it is recommended not to exceed 2.5 m

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(7\)

PRELIMINARY CHECKS

Check that the structure of the gate is sturdy and in good condition, that the hinges are well greased and that the gate moves throughout its entire travel smoothly without impediment or friction.
Always install mechanical stops in the gate open and gate closed positions, anchored securely to the ground and with elastic damper elements (e.g. rubber buffer) to attenuate the impact of the gate leaf against the stop.
Depending on the model installed, on the available space and any obstacles existing in the installation site, and on the required angle of aperture, install the rear bracket on the pillar and the check that the installation measurements indicated in the table are correct.

The measurements [A] and [B] must always be compatible with the maximum effective travel of the piston. If the sum of the values [A]+[B] is greater than the maximum travel, shorten the rear bracket to reduce measurement [B] N.B: The end of the piston rod must meet the gate leaf.

BE20/200 BE20/200/HS

Corsa massima • Max run = 400 mm


A| B| C

(max)

| D (max)| E| α°
110| 180| 100| 770| 92| 100°
110| 210| 100| 770| 92| 95°
120| 150| 100| 770| 92| 105°
120| 200| 100| 770| 92| 100°
130| 130| 100| 770| 92| 105°
150| 130| 100| 770| 92| 120°
150| 150| 100| 770| 92| 110°
150| 200| 100| 770| 92| 100°
160| 150| 100| 770| 92| 105°
160| 160| 100| 770| 92| 100°
BE20/400

Corsa massima • Max run = 550 mm


A| B| C

(max)

| D (max)| E| α°
120| 180| 150| 922| 125| 100°
120| 200| 150| 922| 125| 95°
150| 180| 150| 922| 125| 105°
150| 220| 150| 922| 125| 100°
170| 200| 150| 922| 125| 105°
200| 200| 150| 922| 125| 110°
200| 240| 150| 922| 125| 100°
220| 180| 150| 922| 125| 110°
220| 200| 150| 922| 125| 100°
250| 190| 150| 922| 145| 115°

BRACKETS FASTENING

FASTENING BRACKETS

  1. Fasten the rear bracket in a perfectly level position and in accordance with the installation measurements indicated in paragraph 6.
    • For masonry/cement pillars, use the specific masonry brackets with suitable anchor bolts and screws.
    • With steel pillars, weld the bracket in place.
  2. With the gate completely closed, fit the front bracket to obtain the installation measurements [D] and [E], and fasten in a perfectly level position to the gate leaf as shown in the figure.

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(9\)

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(10\)

INSTALLATION BE20 DRIVE UNIT

  • The BE20 piston may be installed on the right or left hand side.
  • Fasten the piston to the rear bracket and to the front bracket, lubricating the pivot points.
  • Move the gate manually and check that it moves smoothly throughout its entire travel without impediment or friction.

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(11\)

MECHANICAL STOPS ADJUSTMENT

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(12\)

Use the internal mechanical stops in the piston as a supplementary safety measure in addition to the mechanical stops of the gate.

WARNING: the mechanical stops have become loose inside the piston. Even if not used, they must always be securely fastened.
Mechanical stops in the gate open and gate closed positions must always be used.

Adjust the mechanical stops from underneath, or:

  • Remove the cap [A], unscrew and remove the tie rod [B] and remove the drive screw cover [C].
  • Move the gate into the fully open position and adjust the gate open mechanical stop [D].
  • Perform the same procedure in the gate closed position to adjust the gate closed mechanical stop [E].

ELECTRICAL CONNECTIONS
The electrical connections and test procedure for BE20 gear motors are illustrated in the figure and in the installation manual of the B70/2ML or EDGE1 control unit.
N.B.: It is NOT necessary to perform the earth connection .

ROGER-Serie-BE20-Swing-Gates-Automations-FIG- \(13\)

ROGER TECHNOLOGY
Via S. Botticelli 8 • 31021 Bonisiolo di Mogliano Veneto (TV) • ITALIA
P.IVA 01612340263 • Tel. +39 041.5937023 • Fax. +39 041.5937024
info@rogertechnology.comwww.rogertechnology.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals