Svan SVTE100A3 Wall Mounted Water Heater Instruction Manual

June 13, 2024
Svan

Svan SVTE100A3 Wall Mounted Water Heater

IMPORTANT RULES

  1. The replacement of the power cord should be done by professionals.
  2. The use of the appliance by children and vulnerable people must be done under supervision.
  3. The drain pipe should be in a frost protected area. Users must protect inlet and outlet drain lines from freezing.
  4. The electric water heater meets the requirements of EN-60335-1, EN-60335-2-21.

Special advise

  • Before installing this water heater, check and confirm the earth electrode on the socket is reliably grounded, without electricity. Otherwise, the electrical water heater can not be installed and used.
  • No use of mobile sockets.
  • Incorrect installation and use of this electrical water heater may result in serious injuries to human bodies and losses of property.

Performance characteristics

  1. Completely automatic control: automatic addition of cold water, automatic heating.
  2. Four-fold safety protection: multiple safety protection devices, such as dry heating protection, extra-temperature protection, electric leakage protection, high hydraulic pressure protection, etc., safe and reliable.
  3. Sapphire enamel inner container: manufactured by using advanced electrostatic dry method enamel technique, anti rust, corrosion-proof, incrustation-resistant, leak-prevention, with longer lifetime.
  4. Heating pipes designed with low thermal load: safe and reliable, with longer lifetime.
  5. Equipped with corrosion-proof and incrustation-retardant equipment: durable products.
  6. Thickened urethane integral foaming: good thermal insulation effect, energy efficient and electricity saving.
  7. Imported temperature controller: accurate and reliable control of temperature.
  8. Adjustable range of water temperature from 30 to 75°C.
  9. Simple operation and easy use

Specifications

Model| Volume (L)| Rated powerl (W)| Rated voltagel (ACV)| Pated pressure (MPa)| Max of water temperature (     )| Electric type| Waterproof grade
---|---|---|---|---|---|---|---
ST3000| 28| 1500| 220-240| 0.75| 75| Type I| IPX4
ST5000| 47| 1500| 220-240| 0.75| 75| Type I| IPX4
ST8000| 73| 1500| 220-240| 0.75| 75| Type I| IPX4
ST10000| 92| 1500| 220-240| 0.75| 75| Type I| IPX4

Brief introduction of product structure

Methods of installation

Note: Please be sure to use the accessories provided by our company to install this electrical water heater. This electrical water heater can not be hung on the support until it has been confirmed to be firm and reliable. Otherwise, the electrical water heater may drop off from the wall, resulting in damage of the heater, even serious accidents of injury. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electrical heater, to convenient the maintenance of the heater, if necessary

Installation of the main machine

This electrical water heater shall be installed in the solid wall. If the strength of the wall can not bear the load equal to two times of the total weight of the heater filled fully with water, it is necessary to install a special support

After selecting a proper location, determine the positions of the two install holes used for expansion bolts with hook (200mm). Make two holes in the wall with the corresponding depth by using a chopping bit with the size matching the expansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electrical water heater on it (see Fig.2)

Volume (L) 28 47 73 92
Distance between holes (mm) 200

Install the supply socket in the wall. The requirements for the socket are as follows: 250V/1 0A, single phase, three electrodes. It is recommended to place the socket on the right above the heater. The height of the socket to the ground shall not be less than 1.8m (see Fig.3).
If the bathroom is too small, the heater can be installed at another place without sun-scorched and rain-drenched. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location for use of water as near as possible.

Connection of pipelines

The dimension of each pipe part is G1/2.
Connection of one-way safety valve: install the one-way safety valve attached with the machine at the water inlet of the main machine. (Pay attention to keep the installed drainage flexible pipes of the safety valve sloping downward and connected with the atmosphere.)
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the machine must be added at the end of the threads (see Fig.3)

If the users want to realize a multi-way supply system, refer to the method shown in Fig.4 for connection of the pipelines.

Methods of use

  1. First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet valve. The electrical water heater begins to be filled with water. When there is water coming out of the outlet valve normally, it implies that the heater has been filled fully with water, and the outlet valve can be closed.
    Note: During normal operation, the inlet valve shall be set in the status of “open”.

  2. Insert the supply plug into the socket, the two indicator lights are on at this time.

  3. This machine can automatically control the temperature. When the water temperature inside the machine has reached the set temperature (It is set to 75°C), it will be turned off automatically, and step into the status of thermal insulation; when the water temperature is decreased to a certain point, it will be turned on automatically to restore the heating, and the use of hot water will not be interrupted. When the heater is switched off automatically, the heating indicator will turn off.

Cautions

  1. The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 1 OA. The socket and plug shall be kept dry to prevent electrical leakage. Inspect frequently whether the plugs contact well with the socket. Inspect method is as follows: insert the power supply plug into socket, after using for half an hour, shut down the unit and pull the plug out, and inspect the plug whether it scalds hand. If it scalds ( over 50 °C ), please change another well-contacted socket to avoid the plug being damaged, fire or other personnel accidents result from bad-contacting.

  2. For the places or the wall where the water may splash, the installation height of the socket shall not be lower than 1.8m.

  3. The wall in which the electrical water heater is installed shall be able to bear the load more than two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures shall be adopted.

  4. The one-way safety valve attached with the machine must be installed  at the cold water inlet of this machine (see Fig.5). and make sure it is safety valve, so the outflow pipe must open wide in the air; The one-way safety valve need to be checked and cleaned regularly, so as to make sure it will not be blocked.

  5. For the use of the first time (or the first use after maintenance or clean), the heater can not be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water.

  6. During heating, there may be drops of water dripping from the pressure release hole of the one-way safety valve. This is a normal phenomenon. If there is a large amount of water leaked, please contact with the professional maintenance personnel for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the pressure release hole heater may be damaged, even resulting in safety accidents.

  7. The drainage pipe connected to the pressure release hole must be kept sloping downwards.

  8. Since the water temperature inside the heater can reach up to 75°C, the hot water must not be exposed to human bodies when it is initially used. Adjust the water temperature to a proper point to avoid scald.

  9. In order to drain away the water inside the inner container, it can be drained away from the exit port (Twist the thread screw of the exit port off), and it also can be drained away from the one-way safety valve (Twist the thread screw off the one-way safety valve, and lift the drain handle upwards). (See Fig. 7)

  10. If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected, and replaced by the professional maintenance personnel.

  11. If any parts and components of this electrical water heater are damaged, please contact with the professional maintenance personnel for repair, and use the special spare parts and components provided by our company

Maintenance

  1. Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheat phenomenon.
  2. If the heater will not be used for a long time, especially in the regions with low atmospheric temperature (lower than Q°C), in order to prevent the heater to be damaged due to freeze of the water in the inner container, the water inside the heater shall be drained away (refer to Item 9, Cautions of this manual for the method to drain away the water inside the inner container).
  3. In order to ensure that the water heater can operate efficiently for long term, it is recommended to clean periodically the inner container and the deposits on the electrical heating components of the electrical water heater.
  4. Suggest to examine the anode protection materials every half a year or so. If all the materials have been consumed, please replace with the new materials.
  5. Temperature limiter cut off electricity if water heater is overheated or thermostat damages. Manual resetting is needed. Resetting knob is as follows (see Fig.7).

WARNING
Non-professionals are not allowed to disassemble temperature limiter to reset . Please contact professionals to maintain. Otherwise our company will not take responsibility if any quality accident happens because of this

Failures and treatment

Failures Reasons Treatment
The heating indicator light is off. Failures of the temperature controller.

Contact with the professional personnel for repair.
No water coming out of the hot water outlet.|

  1. The running water supply is off.
  2. The hydraulic pressure is too low.
  3. The inlet valve of running water is not open.

|

  1. Wait for restoration of running water supply.

  2. Use the heater again when the hydraulic pressure is increased.
    Open the inlet valve

  3. Open the inlet valve of running water.

The water temperature is too high.|

  1. Failures of the temperature control system.

| Contact with the professional personnel for repair.
Water leak| Seal problem of the joint of each pipe.| each Seal up the joints.

Wiring Diagram

Produce information with EU regulation

The electrical storage water heater ST3000 of the company SVAN Ltd. was tested with a declared load profile of the size “S” that correspond to the water heating efficiency class The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency ηwh =33% of that correspond to the water heating efficiency class “C” In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec, water heating energy efficiency ηwh and mixed water at 40℃(V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Qcor -0.323 kWh
Referenct energy Qref 2.1 kWh
Useful energy content QH2O 2.791 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.753 kWh
Daily electricity consumption (measured) Qtest_elec 3.562 kWh
Water temperature at the beginning of the 24h measurement cycle T3 75.3
Water temperature at the end of the 24h measurement cycle T5 76
Storage volume Mact 28.6 kg
Storage volume Cact 28.6 L
Daily electricity consumption (corrected) Qelec 2.663 kWh
Water heating energy efficiency ηwh 33.2 %
Annual Electricity Consumption AEC 556 kWh
Water heating energy efficiency class C
Water temperature without tapping Tset 75.5
Average water temperature of outlet warm water θ’p 66.3
Average water temperature of inlet cold water θc 10.5
Normalised value of the average temperature θp 66.2
Volume that delivered water of at least 40℃ V40exp 25.7 L
Calculated volume that delivered hot water of at least 40℃ V40 48 L

The electrical storage water heater ST5000 of the company SVAN Ltd. was tested with a declared load profile of the size “M” that correspond to the water heating efficiency class The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of  ηwh =37%   that correspond to the water heating efficiency class “C” In accordance with AnnexⅡ Energy Efficiency Classes  article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water   at 40℃(V40)
The electrical storage water heater ST5000 of the company SVAN Ltd. was tested with a declared load profile of the size that correspond to the water heating efficiency class The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Qcor -0.392 kWh
Referenct energy Qref 5.845 kWh
Useful energy content QH2O 7.143 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.818 kWh
Daily electricity consumption (measured) Qtest_elec 8.068 kWh
Water temperature at the beginning of the 24h measurement cycle T3 69.7
Water temperature at the end of the 24h measurement cycle T5 71.4
Storage volume Mact 46.6 kg
Storage volume Cact 46.6 L
Daily electricity consumption (corrected) Qelec 6.527 kWh
Water heating energy efficiency ηwh 36.7 %
Annual Electricity Consumption AEC 1399 kWh
Water heating energy efficiency class C
Water temperature without tapping Tset 70
Average water temperature of outlet warm water θ’p 67.2
Average water temperature of inlet cold water θc 10.5
Normalised value of the average temperature θp 67.1
Volume that delivered water of at least 40℃ V40exp 36.8 L
Calculated volume that delivered hot water of at least 40℃ V40 70 L

The electrical storage water heater ST8000 of the company SVAN Ltd. was tested with a declared load profile of the size “M” that correspond to the water heating efficiency class The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=37% that correspond to the water heating efficiency class   “C” In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Qcor -0.351 kWh
Referenct energy Qref 5.845 kWh
Useful energy content QH2O 7.480 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.781 kWh
Daily electricity consumption (measured) Qtest_elec 8.420 kWh
Water temperature at the beginning of the 24h measurement cycle T3 57.4
Water temperature at the end of the 24h measurement cycle T5 57.8
Storage volume Mact 81 kg
Storage volume Cact 81 L
Daily electricity consumption (corrected) Qelec 6.550 kWh
Water heating energy efficiency ηwh 36.6 %
Annual Electricity Consumption AEC 1403 kWh
Water heating energy efficiency class C
Water temperature without tapping Tset 57.8
Average water temperature of outlet warm water θ’p 54.9
Average water temperature of inlet cold water θc 10.4
Normalised value of the average temperature θp 54.8
Volume that delivered water of at least 40℃ V40exp 61 L
Calculated volume that delivered hot water of at least 40℃ V40 91 L

The electrical storage water heater ST10000 of the company SVAN Ltd. was tested with a declared load profile of the size “M” that correspond to the water heating efficiency class  The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=36% that correspond to the water heating efficiency class  “C” In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec、water heating energy efficiency ηwh and mixed water at 40℃(V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Qcor -0.472 kWh
Referenct energy Qref 5.845 kWh
Useful energy content QH2O 7.107 kWh
Correction ratio of reference and useful energy Qref/QH2O 0.822 kWh
Daily electricity consumption (measured) Qtest_elec 7.918 kWh
Water temperature at the beginning of the 24h measurement cycle T3 58.1
Water temperature at the end of the 24h measurement cycle T5 56.5
Storage volume Mact 101 kg
Storage volume Cact 101 L
Daily electricity consumption (corrected) Qelec 6.667 kWh
Water heating energy efficiency ηwh 36.1 %
Annual Electricity Consumption AEC 1422 kWh
Water heating energy efficiency class C
Water temperature without tapping Tset 56.4
Average water temperature of outlet warm water θ’p 55.3
Average water temperature of inlet cold water θc 10.4
Normalised value of the average temperature θp 55.3
Volume that delivered water of at least 40℃ V40exp 74 L
Calculated volume that delivered hot water of at least 40℃ V40 112 L

Description to ANNEX I

DESCRIPTION TO ANNEX I

(1) supplier’s name or trade mark
(2) supplier’s model identifier
(3) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of Annex VII
(4) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II
(5) the water heating energy efficiency in %, rounded to the nearest integer
(6) the annual electricity consumption in KWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII
(7) the thermostat temperature settings of the water heater, as placed on the market
(8) the daily electricity consumption Q elec in KWh, rounded to three decimal places
(9) the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex
(10) the mixed water at 40℃ V40 in litres, rounded to the nearest integer
(11) maximum temperature of the thermostat
(12) ‘out of the box-mode’ is the standard operating condition, setting or mode set by the manufacturer at factory level, to be active immediately after the appliance installation, suitable for normal use by the end-user according to the water tapping pattern for which the product has been designed and placed on the market
(13) the water heating energy efficiency in %, rounded to one decimal place
(14) All specific precautions for assembly, installation and maintenance are described in the operating and installation instructions. Read and follow the operating and installation instructions.
(15) All of the data that is included in the product information was determined by applying the specifications of the relevant European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid.

Customer Service

SVAN TRADING S.L.
Imported by B73737553
Av. Altos Hornos S/N. Pto. Sagunto (46520). Valencia, España.
info@svanelectro.com
96060003
Svan Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals