ABB NS53E-25 Contactor Relay User Manual

June 13, 2024
ABB

ABB NS53E-25 Contactor Relay

Product Details

  • Product Name: NS53E-25 220V50/60HZ Contactor Relay
  • Extended Product Type: NS53E-25
  • Product ID: 1SBH101001R2553
  • EAN: 3471523006256
  • Catalog Description: NS53E-25 220V50/60HZ Contactor Relay
  • Long Description: Contactor relays are used for switching auxiliary circuits and control circuits. The contactor relay has 8 poles with mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. The control circuit is AC operated with a laminated magnet circuit. It comes with a wide range of accessories.
  • Ordering: Minimum order quantity is 32 pieces
  • Customs Tariff Number: 85364900

Product Usage Instructions

  1. Dimensions:

    • Net Width: 45 mm
    • Net Depth / Length: 100.2 mm
    • Net Height: 68 mm
    • Net Weight: 0.26 kg
  2. Technical:

    • Number of Auxiliary Contacts NO: 2

    • Number of Auxiliary Contacts NC: 3

    • Standards: Rated Operational Voltage – Auxiliary Circuit: 690 V, Main Circuit: 690 V

    • Rated Frequency (f): Auxiliary Circuit – 50 / 60 Hz

    • Conventional Free-air Thermal Current (Ith): 2 A (690 V)

    • Rated Operational Current AC-15 (Ie): Auxiliary Circuit – 6 A
      (24 / 127 V), 4 A (220 / 240 V), 3 A (400 / 440 V)

    • Rated Short-time Withstand Current Low Voltage (Icw): for 0.1 s
      – 140 A, for 1 s – 100 A

    • Maximum Electrical Switching Frequency: Rated Operational
      Current DC-13 (Ie) – 1200 cycles per hour

    • Rated Insulation Voltage (Ui): Auxiliary Circuit – 690 V, Rated
      Impulse Withstand Voltage (Uimp): Auxiliary Circuit – 6 kV

    • Maximum Mechanical Switching Frequency: 3600 cycles per hour

    • Rated Control Circuit Voltage (Uc): 50 Hz – 220 V, 60 Hz – 220 V

    • Operate Time: Between Coil De-energization and NC Contact
      Closing – 7 to 22 ms, Between Coil De-energization and NO Contact
      Opening – 5 to 19 ms, Between Coil Energization and NC Contact
      Opening – 6 to 18 ms, Between Coil Energization and NO Contact
      Closing – 9 to 24 ms

    • Connecting Capacity Auxiliary Circuit: (24 V) – 6 A / 144 W, (48 V) – 2.8 A / 134 W, (72 V) – 1 A / 72 W, (110 V) – 0.55 A / 60 W, (125 V) – 0.55 A / 69 W, (220 V) – 0.27 A / 60 W, (250 V) – 0.27 A / 68 W

    • Connecting Capacity Control Circuit: Auxiliary Circuit – 9 mm,
      Control Circuit – 9 mm

    • Wire Stripping Length: Not specified

    • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 IP20

    • Terminal Type: Screw Terminals

  3. Environmental:

    • Ambient Air Temperature: Not specified

    • Climatic Withstand: Not specified

    • Maximum Operating Altitude: Not specified

    • Permissible Resistance to Vibrations: acc. to IEC
      60068-2-6

    • Resistance to Shock: acc. to IEC 60068-2-27

    • RoHS Status: Not specified

  4. Certificates and Declarations:

    • CB Certificate: Not specified
    • CCC Certificate: Not specified
    • CQC Certificate: Not specified
    • Declaration of Conformity – CCC: Not specified
    • Declaration of Conformity – CE: Not specified
    • Declaration of Conformity – UKCA: Not specified
    • GOST Certificate: Not specified
    • UL Certificate: Not specified
    • UL Listing Card: Not specified
  5. Container Information:

    • Package Level 1 Units: Not specified
    • Package Level 1 Width: Not specified
    • Package Level 1 Depth / Length: Not specified
    • Package Level 1 Height: Not specified
    • Package Level 1 Gross Weight: Not specified
    • Package Level 1 EAN: Not specified
    • Package Level 2 Units: Not specified
    • Package Level 2 Width: Not specified
    • Package Level 2 Depth / Length: Not specified
    • Package Level 2 Height: Not specified
    • Package Level 2 Gross Weight: Not specified
    • Package Level 3 Units: Not specified

General Information

  • Extended Product Type NS53E-25
  • Product ID 1SBH101001R2553
  • EAN 3471523006256
  • Catalog Description NS53E-25 220V50/60HZ Contactor Relay
    Long Description NS… contactor relays are used for switching auxiliary circuits and control circuits. – Poles: 8-pole contactor relays (mechanically- linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the “Mechanically Linked” symbol on the contactor relay side) – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.

Ordering

  • Minimum Order Quantity 32 piece
  • Customs Tariff Number 85364900

Popular Downloads

  • Instructions and Manuals 1SBC101020M9701
  • CAD Dimensional Drawing 2CDC001079B0201

Dimensions

  • Product Net Width 45 mm
  • Product Net Depth /Length 100.2 mm
  • Product Net Height 68 mm
  • Product Net Weight 0.26 kg

Technical

  • Number of Auxiliary Contacts NO 5

  • Number of Auxiliary Contacts NC 3

  • Standards IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14

  • Rated Operational Voltage Auxiliary Circuit 690 V Main Circuit 690 V

  • Rated Frequency (f) Auxiliary Circuit 50 / 60 Hz

  • Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-5-1, Θ = 40 °C 10 A

  • Rated Operational Current AC-15 (Ie) (500 V) NC 2
    (500 V) 2 A
    (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (400 / 440 V) 3 A

  • Rated Short-time for 0.1 s 140 A

  • Withstand Current Low Voltage (Icw) for 1 s 100 A

  • Maximum Electrical (AC-15) 1200 cycles per hour

  • Switching Frequency (DC-13) 900 cycles per hour

  • Rated Operational Current (24 V) 6 A / 144 W
    DC-13 (Ie) (48 V) 2.8 A / 134 W
    (72 V) 1 A / 72 W
    (110 V) 0.55 A / 60 W
    (125 V) 0.55 A / 69 W
    (220 V) 0.27 A / 60 W
    (250 V) 0.27 A / 68 W

  • Rated Insulation Voltage acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V

  • (Ui) acc. to UL/CSA 600 V

  • Rated Impulse Withstand Voltage (Uimp) Auxiliary Circuit 6 kV

  • Maximum Mechanical Switching Frequency 3600 cycles per hour

  • Rated Control Circuit 50 Hz 220 V

  • Voltage (Uc) 60 Hz 220 V

  • Operate Time Between Coil De-energization and NC Contact Closing 7 … 22 ms

  • Between Coil De-energization and NO Contact Opening 5 … 19 ms

  • Between Coil Energization and NC Contact Opening 6 … 18 ms

  • Between Coil Energization and NO Contact Closing 9 … 24 ms

  • Connecting Capacity Flexible with Ferrule 1/2x 0.75 … 2.5 mm²

  • Auxiliary Circuit Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²

  • Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²

  • Rigid 1/2x 0.75 … 2.5 mm²

  • Connecting Capacity Flexible with Ferrule 1/2x 0.75 … 2.5 mm²

  • Control Circuit Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²

  • Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²

  • Rigid 1/2x 0.75 … 2.5 mm²

  • Wire Stripping Length Auxiliary Circuit 9 mm

  • Control Circuit 9 mm

  • Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20

  • acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

  • Terminal Type Screw Terminals

Technical UL/CSA

  • Tightening Torque Auxiliary Circuit 9 in·lb
  • UL/CSA Control Circuit 9 in·lb

Environmental

  • Ambient Air Temperature Close to Contactor for Storage -60 … +80 °C

  • Near Contactor for Operation in Free Air -40 … 70 °C

  • Climatic Withstand Category B according to IEC 60947-1 Annex Q

  • Maximum Operating Altitude Permissible Without Derating 3000 m

  • Resistance to Vibrations acc. to IEC 60068-2-6 5 … 300 Hz 3 g Closed position / 2 g Open position

  • Resistance to Shock acc. to IEC 60068-2-27 Closed, Shock Direction: C1 19 g
    Closed, Shock Direction: C2 16 g
    Open, Shock Direction: C1 8 g
    Open, Shock Direction: C2 13 g
    Shock Direction: A 20 g
    Shock Direction: B1 5 g
    Shock Direction: B2 15 g

  • RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations

  • CB Certificate CB_CN_32453
  • CCC Certificate CCC_2007010305248106
  • CQC Certificate CQC2007010305248106
  • Declaration of Conformity – CCC 2020980304001219
  • Declaration of Conformity- CE 1SBD250016U1000
  • Declaration of Conformity – UKCA 1SBD250051U1000
  • GOST Certificate GOST_POCCCNME77B07821.pdf
  • UL Certificate UL_220108-E312527A
  • UL Listing Card NOA_E312527.pdf

Container Information

  • Package Level 1 Units 1 piece
  • Package Level 1 Width 72 mm
  • Package Level 1 Depth /Length 115 mm
  • Package Level 1 Height 48 mm
  • Package Level 1 Gross Weight 0.26 kg
  • Package Level 1 EAN 3471523006256
  • Package Level 2 Units 32 piece
  • Package Level 2 Width 250 mm
  • Package Level 2 Depth /Length 315 mm
  • Package Level 2 Height 195 mm
  • Package Level 2 Gross Weight 8.32 kg
  • Package Level 3 Units 768 piece

Classifications

  • Object Classification Code K
  • ETIM 4 EC000196 – Contactor relay
  • ETIM 5 EC000196 – Contactor relay
  • ETIM 6 EC000196 – Contactor relay
  • ETIM 7 EC000196 – Contactor relay
  • ETIM 8 EC000196 – Contactor relay
  • eClass V11.0 : 27371001
  • UNSPSC 39121529
  • IDEA Granular Category Code (IGCC) 4761 >> Magnet contactor, AC-switching