ABB NS62ES-26 Contactor Relay User Manual

June 13, 2024
ABB

ABB NS62ES-26 Contactor Relay

Product Details

Product Name: NS62ES-26 Contactor Relay
Extended Product Type: NS62ES-26 1SBH101004R2662
EAN: 2CDC001079B0201
Catalog Description: NS62ES-26 230V50/60HZ Contactor Relay
Long Description: The NS62ES-26 Contactor Relay is a high-quality electrical component designed for reliable switching of electrical circuits.
Minimum Order Quantity: 32 pieces
Customs Tariff Number: 85364900

Product Usage Instructions

Dimensions:

  • Product Net Width: 45 mm
  • Product Net Depth / Length: 110.7 mm
  • Product Net Height: 68 mm
  • Product Net Weight: 0.26 kg

Technical Specifications:

  • Number of Auxiliary Contacts NO: 2

  • Number of Auxiliary Contacts NC: 2

  • Standards: Rated Operational Voltage (Auxiliary Circuit): 690
    V, Rated Operational Voltage (Main Circuit): 690 V

  • Rated Frequency (f): Auxiliary Circuit – 50 / 60 Hz

  • Conventional Free-air Thermal Current (Ith): 2 A (690 V)

  • Rated Operational Current AC-15 (Ie): Auxiliary Circuit – 6 A
    (220 / 240 V), Main Circuit – 3 A (400 / 440 V)

  • Rated Short-time Withstand Current Low Voltage (Icw): for 0.1 s
    – 140 A, for 1 s – 100 A

  • Maximum Electrical Switching Frequency: (AC-15) 1200 cycles per
    hour, (DC-13) 900 cycles per hour

  • Rated Operational Current DC-13 (Ie): Auxiliary Circuit – 6 A /
    144 W (24 V), Main Circuit – 2.8 A / 134 W (48 V)

  • Rated Insulation Voltage (Ui): Auxiliary Circuit – 690 V, Main
    Circuit – 690 V

  • Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit – 6
    kV

  • Maximum Mechanical Switching Frequency: 3600 cycles per
    hour

  • Rated Control Circuit Voltage (Uc): Auxiliary Circuit – 50 Hz
    230 V, Main Circuit – 60 Hz 230 V

  • Operate Time: Between Coil De-energization and NC Contact
    Closing – 7 … 22 ms, Between Coil De-energization and NO Contact
    Opening – 5 … 19 ms, Between Coil Energization and NC Contact
    Opening – 6 … 18 ms, Between Coil Energization and NO Contact
    Closing – 9 … 24 ms

  • Connecting Capacity Auxiliary Circuit: 10 mm

  • Connecting Capacity Control Circuit: 10 mm

  • Wire Stripping Length: Not specified

  • Degree of Protection: IP20

  • Terminal Type: Spring Terminals

Environmental Specifications:

  • Ambient Air Temperature: Not specified
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q Without Derating
  • Maximum Operating Altitude: 3000 m
  • Permissible Resistance to Vibrations acc. to IEC 60068-2-6: 5 … 300 Hz 3 g Closed position / 2 g Open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock
  • Direction: C1 19 g Closed, Shock Direction: C2 16 g

Certificates and Declarations:

  • RoHS Status: Not specified
  • CB Certificate: Available
  • CCC Certificate: Available
  • CQC Certificate: Available
  • Declaration of Conformity – CCC: Available
  • Declaration of Conformity – CE: Available
  • Declaration of Conformity – UKCA: Available
  • GOST Certificate: Available
  • UL Certificate: Available

Package Information:

  • Package Level 1 Units: Not specified
  • Package Level 1 Width: Not specified
  • Package Level 1 Depth / Length: Not specified
  • Package Level 1 Height: Not specified
  • Package Level 1 Gross Weight: Not specified
  • Package Level 1 EAN: Not specified
  • Package Level 2 Units: Not specified
  • Package Level 2 Width: Not specified
  • Package Level 2 Depth / Length: Not specified
  • Package Level 2 Height: Not specified
  • Package Level 2 Gross Weight: Not specified
  • Package Level 3 Units: Not specified

Classifications:

  • Object Classification Code ETIM 4: Not specified
  • Object Classification Code ETIM 5: Not specified
  • Object Classification Code ETIM 6: Not specified

General Information

  • Extended Product Type NS62ES-26
  • Product ID 1SBH101004R2662
  • EAN 3471523013261
  • Catalog Description NS62ES-26 230V50/60HZ Contactor Relay
    Long Description NS… contactor relays are used for switching auxiliary circuits and control circuits. The NS..S contactor relays are the spring terminal version of the NS… range. – Poles: 8-pole contactor
    relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the “Mechanically Linked” symbol on the contactor relay side) – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.

Ordering

  • Minimum Order Quantity 32 piece
  • Customs Tariff Number 85364900

Popular Downloads

  • Instructions and Manuals 1SBC101020M9701
  • CAD Dimensional Drawing 2CDC001079B0201

Dimensions

  • Product Net Width 45 mm
  • Product Net Depth /Length 110.7 mm
  • Product Net Height 68 mm
  • Product Net Weight 0.26 kg

Technical

  • Number of Auxiliary Contacts NO 6

  • Number of Auxiliary Contacts NC 2

  • Standards IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14

  • Rated Operational Voltage Auxiliary Circuit 690 V Main Circuit 690 V

  • Rated Frequency (f) Auxiliary Circuit 50 / 60 Hz

  • Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-5-1, Θ = 40 °C 10 A

  • Rated Operational Current (500 V) NC 2
    AC-15 (Ie) (500 V) 2 A (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (400 / 440 V) 3 A

  • Rated Short-time for 0.1 s 140 A

  • Withstand Current Low

  • Voltage (Icw) for 1 s 100 A

  • Maximum Electrical (AC-15) 1200 cycles per hour

  • Switching Frequency (DC-13) 900 cycles per hour

  • Rated Operational Current (24 V) 6 A / 144 W
    DC-13 (Ie) (48 V) 2.8 A / 134 W
    72 V) 1 A / 72 W
    (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W

  • Rated Insulation Voltage acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
    (Ui) acc. to UL/CSA 600 V

  • Rated Impulse Withstand Voltage (Uimp) Auxiliary Circuit 6 kV
    Maximum Mechanical Switching Frequency 3600 cycles per hour

  • Rated Control Circuit 50 Hz 230 V

  • Voltage (Uc) 60 Hz 230 V

  • Operate Time Between Coil De-energization and NC Contact Closing 7 … 22 ms

  • Between Coil De-energization and NO Contact Opening 5 … 19 ms

  • Between Coil Energization and NC Contact Opening 6 … 18 ms

  • Between Coil Energization and NO Contact Closing 9 … 24 ms

  • Connecting Capacity Flexible with Ferrule 1/2x 0.75 … 2.5 mm²

  • Auxiliary Circuit Flexible with Insulated Ferrule 1/2x 0.75 … 1.5 mm²
    Rigid 1/2x 0.75 … 2.5 mm²

  • Connecting Capacity Flexible with Ferrule 1/2x 0.75 … 2.5 mm²

  • Control Circuit Flexible with Insulated Ferrule 1/2x 0.75 … 1.5 mm²
    Rigid 1/2x 0.75 … 2.5 mm²

  • Wire Stripping Length Auxiliary Circuit 10 mm

  • Control Circuit 10 mm

  • Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

  • Terminal Type Spring Terminals

Environmental

  • Ambient Air Temperature Close to Contactor for Storage -60 … +80 °C
  • Near Contactor for Operation in Free Air -40 … 70 °C
  • Climatic Withstand Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible Without Derating 3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6 5 … 300 Hz 3 g Closed position / 2 g Open position
  • Resistance to Shock acc. to IEC 60068-2-27 Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 16 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 13 g Shock Direction: A 20 g
  • Shock Direction: B1 5 g
  • Shock Direction: B2 15 g
  • RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations

  • CB Certificate CB_CN_32453
  • CCC Certificate CCC_2007010305248106
  • CQC Certificate CQC2007010305248106
  • Declaration of Conformity – CCC 2020980304001219
  • Declaration of Conformity – CE 1SBD250016U1000
  • Declaration of Conformity – UKCA 1SBD250051U1000
  • GOST Certificate GOST_POCCCNME77B07821.pdf
  • UL Certificate UL_220108-E312527A

Container Information

  • Package Level 1 Units  1 piece
  • Package Level 1 Width 72 mm
  • Package Level 1 Depth /Length 115 mm
  • Package Level 1 Height 48 mm
  • Package Level 1 Gross Weight 0.26 kg
  • Package Level 1 EAN 3471523013261
  • Package Level 2 Width 250 mm
  • Package Level 2 Depth /Length 315 mm
  • Package Level 2 Height 195 mm
  • Package Level 2 Gross Weight 8.32 kg
  • Package Level 3 Units 768 piece

Classifications

  • Object Classification Code K
  • ETIM 4 EC000196 – Contactor relay
  • ETIM 5 EC000196 – Contactor relay
  • ETIM 6 EC000196 – Contactor relay
  • ETIM 7 EC000196 – Contactor relay
  • ETIM 8 EC000196 – Contactor relay
  • eClass V11.0 : 27371001
  • UNSPSC 39121529
  • IDEA Granular Category Code (IGCC) 4761 >> Magnet contactor, AC-switching

Categories

  • Low Voltage Products and Systems → Control Products → Contactors → Block Contactors

© 2023 ABB. All rights reserved.
Subject to change without notice

Read User Manual Online (PDF format)