dyson Gen1 Hot and Cool Purifier User Manual
- June 13, 2024
- dyson
Table of Contents
- Gen1 Hot and Cool Purifier
- Assembling your machine
- Getting started
- Power and continuous monitoring
- Information menu
- Auto mode
- Airflow speed
- Oscillation
- Night mode and Sleep timer
- Heating and Cooling modes
- Changing your HEPA+Carbon filter
- Resetting your HEPA+Carbon filter life
- Looking after your machine
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Gen1 Hot and Cool Purifier
User Manual User manual
SV12 JN.00000 PN.000000-00-00
00.00.00 VERSION NO.01
Gen1 Hot and Cool Purifier
Oscillation
Night mode and Sleep timer
Heating and Cooling modes
Changing your HEPA+Carbon filter
Resetting your HEPA+Carbon filter life
Looking after your machine
Assembling your machine
Use both hands to lift your machine out of the box, by its base.
Do not lift out by the loop amplifier.
Dyson Purifier Hot+Cool Gen1
Supplied with a combined glass HEPA+Carbon filter.
Getting started
Place the remote control on top of the machine with the buttons facing down.
Plug in and switch on.
Power and continuous monitoring
Stand-by on/off
Press the Standby on/off button on your Dyson purifying fan heater or remote
control to stop your machine. It will continue to monitor the air quality.
Continuous monitoring
Continuous monitoring is turned off by default. Once turned on, it will always
be active until you turn it off again.
With continuous monitoring turned on, your Dyson purifying fan heater will
gather particulate matter and temperature information, which is displayed on
the LCD screen.
Continuous monitoring
Press and hold the Auto mode button on the remote control for 5 seconds to
turn it on. The LCD screen will indicate when continuous monitoring is on or
off.
Information menu
Press this button to scroll through the information being monitored by your
Dyson purifying fan heater.
Information about particulate matter, temperature and filter levels is shown
on the LCD screen.
When a particular type of pollutant causes air quality to decrease, a symbol
for the pollutant will show on the LCD screen.
Indoor particulate matter – 12 seconds
Monitors the current particulate matter with a graph showing the last 12
seconds of data.
Particulate matter (PM10)
Microscopic particles up to 2.5 microns in size, suspended in the air we
breathe. These include smoke, bacteria and allergens.
Particulate matter (PM2.5)
Larger microscopic particles up to 10 microns in size, suspended in the air
we breathe. These include dust, mould and pollen.
Indoor temperature
Monitor the ambient temperature to helpmaintain a comfortable environment.
Filters
The remaining filter life is shown on the LCD screen and will indicate when
your filters need replacing.
Auto mode
Set your Dyson purifying fan heater to Auto mode and the on-board sensors will
intelligently adjust the settings of the machine according to the air quality.
Air quality: your machine will pause when the target air quality
has been reached, switching on again when the air quality levels drop.
Airflow speed: the airflow speed will increase until the target air quality
and temperature have been reached.
Airflow speed
Press the Airflow speed button to increase and decrease the airflow speed.
Oscillation
Press the Oscillation button to circulate the air around the room and scroll through the oscillation settings from 0° to 350°.
Night mode and Sleep timer
In Night mode, your Dyson purifying fan heater will continue to monitor and
respond to changes, but only using its quietest settings – and with its LCD
screen dimmed.
Press the Night mode and Sleep timer button to scroll through the timer
options.
Heating and Cooling modes
Press the button to set the required room temperature.
Your machine will pause when the temperature set has been reached.
Press the Cooling mode button to switch your machine from Heating mode to
Cooling mode.
Changing your HEPA+Carbon filter
Before changing your filter, switch off and unplug your Dyson purifier fan
heater.
The remaining filter life is displayed on the screen and will indicate when
your non-washable filters need replacing. Press the Information button on your
remote.
You’ll need to reset the filter life on your machine.
Dyson Purifier Hot+Cool Gen1
Supplied with a HEPA+Carbon filter.
To change your HEPA+Carbon filter, push down on the buttons either side of
your machine to release the outer cover. Push down on the tabs to remove the
filter.
Push the replacement filter into the outer cover and make sure the tabs click
into place.
Put the outer covers into position on your machine and push firmly until they
both click securely into position.
Plug in and switch your machine, and reset your filter life.
Resetting your HEPA+Carbon filter life
It’s important to reset your filter life after you have replaced your filter.
Resetting your HEPA+Carbon filter life
Press and hold the Night mode button on your remote control.
The display on your machine will countdown from five, the filter
life will be reset and your machine is ready to use.
Looking after your machine
To always get the best performance from your Dyson purifying fan heater, it’s
important to regularly clean it and check for blockages.
Cleaning your machine
If your machine is dusty, wipe with a damp lint-free cloth.
Look for blockages in the air inlet holes on the filter and the small aperture
inside the loop amplifier.
Use a soft brush to remove dust and debris.
Don’t use detergents or polishes to clean your machine.
Error codes
If your machine shows an error code, try turning it off and then on again.
If this doesn’t clear the error code contact Dyson Customer Care.