LG LSN090HSV5 Multi F Wall Mounted High Efficiency Indoor Unit Instruction Manual
- June 13, 2024
- LG
Table of Contents
Multi F Wall Mounted High Efficiency Indoor Unit
LSN090HSV5
9,000 Btu/h
Performance:
Nominal Cooling Capacity (Btu/h) | 9,000 |
---|---|
Nominal Heating Capacity (Btu/h) | 10,900 |
Cooling Nominal Test Conditions: | Heating Nominal Test Conditions: |
--- | --- |
Indoor: 80°F DB / 67°F WB | Indoor: 70°F DB / 60°F WB |
Outdoor: 95°F DB / 75°F WB | Outdoor: 47°F DB / 43°F WB |
Electrical:
Power Supply (V¹/Hz/Ø) | 208-230/60/1 |
---|---|
Rated Amps (A) | 0.4 |
Piping:
Installed Liquid Pipe (in., O.D.) | 27/32 , 5/8 |
---|---|
Installed Vapor Pipe (in., O.D.) | Thermistor |
Liquid Connection (in., O.D.) | ø3/8 |
Vapor Connection (in., O.D.) | ø1/4 |
Drain (in., O.D. / I.D.) | ø3/8 |
Temperature Sensor | ø1/4 |
Controls Features:
- 4-Way auto swing
- 24-Hour on/off timer
- Auto operation
- Auto restart
- Chaos wind
- Inverter (variable speed fan)
- Compatible with Single Zone HSV5 Outdoor Units
- Jet cool/Jet heat
- 3M Micro Dust Filter
- Self-cleaning indoor coil
- Sleep mode
- Condensate sensor connection
- Built-in Wi-Fi via Smart ThinQ app
Included Accessories:
- Wireless Remote Controller — AKB74955602
Optional Accessories:
- MultiSITE™ CRC1 – PREMTBVC0
- MultiSITE CRC1+ – PREMTBVC1
- Dry Contact – PDRYCB300
Entering Mixed Air:
Cooling (°F WB) | 57 ~ 77 |
---|---|
Heating (°F DB) | 59 ~ 81 |
Unit Data:
Refrigerant Type | R410A |
---|---|
Refrigerant Control | EEV |
Sound Pressure (H/M/L) (±3 dB[A]) | Washable Pre-filter |
Primary Filter | 3M Micro Dust |
Secondary Filter | 18.3 |
Net Weight (lbs.) | 36 / 32 / 27 |
Shipping Weight (lbs.) | 23.4 |
Fan:
Type | Cross Flow |
---|---|
Quantity | 1 |
Motor/Drive | Brushless Digitally Controlled/Direct |
Air Flow H/M/L (CFM) | 268 / 218 / 169 |
Notes:
- Acceptable operating voltage: 187V-253V.
- Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
- See Engineering Manual for sensible and latent capacities.
- All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
- Power wiring cable size must comply with the applicable local and national code.
- The indoor unit comes with a dry helium charge.
- Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 – 105%.
- Must follow installation instructions in the applicable LG installation manual.
For a complete list of available accessories, contact your LG representative.
For continual product development, LG reserves the right to change
specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG
Life’s Good” is a registered trademark of LG Corp. /
www.lghvac.com
Job Name/Location:……………
Date:………………………………….
PO No.:………………………………
Architect:…………………………….
Engr:…………………………………
Rep (Company): …………………
For:
File……………………………………
Resubmit…………………………..
Approval……………………………
Other………………………………..
GC:…………………………………..
Mech:……………………………….
(Project Manager)
www.ahridirectory.org
SB_MultiF_WallMount_HiEffIDU
LSN090HSV5_2022_11_09_122831