iGPSPORT HR70 Heart Rate Monitor Armband User Guide

June 13, 2024
iGPSPORT

iGPSPORT HR70 Heart Rate Monitor Armband

iGPSPORT-HR70-Heart-Rate-Monitor-Armband-product

Product Information

This product is a wireless device that operates on multiple frequencies including BLE (1M), BLE (2M), ANT+ (1M), and ANT+ (2M). It has an operating temperature range of -10°C to 50°C. The operation frequency is 2457MHz, and the maximum RF output power is -3.56dBm for BLE (1M), -3.47dBm for BLE (2M), -3.23dBm for ANT+ (1M), and -3.47dBm for ANT+ (2M). The RF output power limit for all frequencies is 20 dBm.

Product Usage Instructions

  1. Ensure that the operating temperature is within the specified range of -10°C to 50°C.
  2. Choose the desired operation frequency based on your requirements:
    • If you want to use BLE with a transmission rate of 1M, make sure the device is set to BLE(1M) mode.
    • If you want to use BLE with a transmission rate of 2M, make sure the device is set to BLE(2M) mode.
    • If you want to use ANT+ with a transmission rate of 1M, make sure the device is set to ANT+(1M) mode.
    • If you want to use ANT+ with a transmission rate of 2M, make sure the device is set to ANT+(2M) mode.
  3. Make sure the device is set to the operation frequency of 2457MHz.
  4. Ensure that the RF output power does not exceed the limit of 20 dBm for any frequency.

Following these usage instructions will help you effectively operate the wireless device and avoid any potential issues.

POWER ON AND POWER OFF

  • Power on: short press for 1s, the blue light flashes 3 times quickly and vibrates.
  • Power off: long press for 2s, the red light flashes 3 times quickly and vibrates.

TO WEAR

You can wear the heart rate monitor on the inside or outside of your upper arm or forearm as shown in the image 2. Please adjust the length of the strap so that it fits snugly on the arm, and ensure that the arm strap does not shift during exercise to ensure the accuracy of heart rate measurement.

MAIN FUNCTIONS

Functions/ State or action

  • Turn On: The blue light flashes 3 times quickly and vibrates
  • Turn Off: The red light flashes 3 times quickly and vibrates
  • Charging: Blue light flashes slowly
  • Finished charging: Steady green light
  • Heart rate zone indication: The color corresponding to the heart rate zone flashes slowly
  • Heart rate zone indication: The color corresponding to the heart rate zone flashes slowly
  • Low Heart Rate Alert: The blue light flashes 3 times quickly and vibrates
  • High Heart Rate Alert: The red light flashes 3 times quickly and vibrates
  • Mode switch: Double-click the button in the power-on state
  • Low battery warning (below 9%, 5%): The red light flashes 3 times quickly and vibrates
  • Firmware upgrade: Steady bule light

The functions marked with * need to be set in the iGPSPORT APP.

HEART RATE ZONE INDICATION

The default maximum heart rate is 195 bpm, and the heart rate zones are calculated using the maximum heart rate method.

Heart rate zone/ State

  • Zone 1 (50-60%): Blue light flashes slowly
  • Zone 2 (60-70%): Green light flashes slowly
  • Zone 3 (70-80%): Yellow light flashes slowly
  • Zone 4 (80-90%): Red light flashes slowly
  • Zone 5 (90-100%): Purple light flashes slowly

You can set the maximum heart rate and heart rate zone calculation method in the iGPSPORT APP settings.

CHARGING

  • This product is a magnetic charging method. When charging, please insert one end of the magnetic charging cable into the USB port, and attach the other end to the heart rate armband.
  • During charging, the indicator light flashes blue, and when fully charged, the indicator light will turn green.

PRODUCT ACCESSORIES

  • HR70 main unit X 1
  • Armband × 1
  • Magnetic charging cable × 1
  • HR70 User Quick Guide × 1

CONTACT US

  • www.igpsport.com
  • Wuhan Qiwu Technology Co., Ltd.
  • 3/F Creative Workshop, No. 04 District D Creative World, No. 16 West Yezhihu Road, Hongshan District, Wuhan, Hubei, China.
  • (86)027-87835568
  • service@ignsport.com

Statement

This manual is for user reference only, if there is any difference with the device, please refer to the device. We reserve the right to change or improve our products and the content of this manual, but have no obligation to notify any person or organization of such changes or improvements.

Copyright Wuhan Qiwu Technology Co., Ltd. All rights reserved.

USER MANUAL

Please log in to the official website to view the details of the manual.

Website and QR code

WARNING: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliancecould void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction

FCC ID: 2AU4M-HR70

SPECIFICATION

  • Operating Temperature: -10℃-50℃
  • Product Name: Heart Rate
    Model number: HR70,HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO

WARNING

  • Manufacturer’s Name: Wuhan Qiwu Technology Co.,Ltd.
  • Address: 3 / F, Creative workshop, No.04, District D, Creative world, No.16 Yezhihu West Road, Hongshan District, Wuhan City, Hubei Province, China.
  • This product can be used across all EU member states.
  • Hereby, Wuhan Qiwu Technology Co.,Ltd. declares that this BIKE SMART COMPUTER product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the Declaration of Conformity can be found at Website: www.igpsport.cn

CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS

Care for the environment! Must not be discarded with household waste!

For RF Specification

iGPSPORT-HR70-Heart-Rate-Monitor-Armband-fig-5

Documents / Resources

| iGPSPORT HR70 Heart Rate Monitor Armband [pdf] User Guide
HR70, HR70S, HR70P, HR70C, HR70 PLUS, HR70 PRO, HR70 Heart Rate Monitor Armband, Heart Rate Monitor Armband, Monitor Armband, Armband
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals