TECNOWARE 800 Era Plus Strip Instructions
- June 13, 2024
- TECNOWARE
Table of Contents
800 Era Plus Strip
Instructions UPS ERA PLUS STRIP
LINE INTERACTIVE
800
800 Era Plus Strip
- On/Off switch
- Led line/battery/fault
- Power cable
- Input thermal protection
- Output sockets with child protection and blackout protection
- Filtered output socket with child protetiction
- USB Port
Main Specifications
- Personal Computer, Modem/Router, Cash Register, Pos
- Automatic Voltage Regulation circuit (AVR)
- Easy replacement batteries
- Rear slots for wall mounting
- Output sockets with child protection for blackout protection
- Output sockets with child protection for overvoltage protection
- USB port
- UPS Management Software TecnoManager compatible with Windows, Mac OS X, Unix, Linux, etc.
Specifications
UPS Model | ERA PLUS STRIP 800 |
---|---|
Code | FGCERAPLST800 |
Nominal power | 800 VA |
Max Computer Power Application | 560 W |
Technology | Line Interactive with stabilizer |
Cooling | Natural |
Audible noise | < 40 dBA to 1 m |
Input connection | Fixed cable with Schuko plug |
Outlets | 3 UPS outputs Schuko/Italian +3 only filtered outputs Schuko/Italian |
Dimension (UPS) WxHxD | 16×9,5×30,5 cm |
Dimension (with packing) WxHxD | 22x14x32,4 cm |
Weight | 2,5 Kg |
Input | |
Number of phases | 1Ph+N |
Nominal voltage | Single-phase 230Vac |
Input voltage range | +20%/-25% |
Nominal frequency | 50/60 Hz (automatic selection) |
Input frequency range | +/-5% |
Output | |
Number of phases | 1Ph+N |
Nominal voltage | Single-phase 230Vac |
Active Power | 240 W |
Voltage regulation (Line mode) | AVR (Automatic Voltage Regulation) |
Voltage regulation (Battery mode) | +/-5% |
Frequency | 50/60 Hz (automatic selection) |
Inverter waveform | Modified sinewave |
Overload capability | < 130% |
Transfer time | 2 ms (typical) |
Battery | |
Type | Lead acid, sealed, maintenance free |
Backup time (typical) | 10-40 min |
Environmental specification | |
Working temperature | From 0 to 40 °C (recommended from 20 to 25 °C) |
Humidity | < 95% without condensation |
Maximum altitude | 3000 m |
IP protection | IP20 |
Certifications | CE (Standards: Low Voltage Directive IEC EN 62040-1; EMC |
Directive IEC EN 62040-2; classification IEC EN 62040-3)
Available on request with input/output nominal voltage 110Vac or 120Vac and
with input plug and output sockets for specific country.
© 2023 Tecnoware Power Systems. The technical data may change without prior