Product Information

The Supreme Delta Series Sensor Taps are automatic taps designed for basin mounting. They come in three different models: DL1051DC, DL1051AC, DL3100DC, DL3100AC, DL2251DC, and DL2251AC. These taps feature several useful functions:

  • Low power usage: The taps are powered by 4 x AA batteries, which can last up to 2 years based on 300 cycles per day.
  • Time out protection: If there is continuous washing for over 1 minute, the tap will automatically reset after 10 seconds once the obstruction is removed.
  • Simple maintenance: The taps have a built-in water strainer to prevent dirt and debris from clogging the system.
  • Low power warning: The tap’s sensor has a flashing indicator LED that alerts users when the batteries need to be replaced.
  • 240v connection available: The taps can also be connected to a 240v power supply.

When installing the tap, please note the following:

  • For single-hole basins, the hole diameter should be between 30-32mm.
  • For tri-hole basins, the center hole diameter should be 28mm, and the outside hole diameters should be 102mm.
  • If you are installing the 240V version of the tap, it is recommended to consult with an electrician.
  • Do not use corrosive or abrasive compounds to clean the faucet or detection lens.

ITEMS LIST

SPL-Washrooms-DL3100-Supreme-Delta-Basin-Mounted-Automatic-
Tap-1

FEATURES

  • Low power usage: 4 x AA batteries can last 2 years based on 300 cycles per day
  • Time out protection: 60 seconds, reset 10 seconds after obstruction is removed
  • Simple maintenance: Built in water strainer
  • Low power warning: Flashing indicator LED on sensor
  • 240v connection available

NOTE:

  • Single hole basin:  Hole diameter 30-32mm
  • Tri-hole basin: Centre hole diameter 28mm and outside hole diameters 102mm
  • When installing 240V version please consult your electrician
  • Do not use corrosive or abrasive compounds to clean the faucet or detection lens.

SPECIFICATIONS

  • Control Box Dimensions (WxHxD) 110mm x 110mm x 57mm
  • Faucet Dimensions 42mm Ø x 277mm high
  • Power DC —4 x 1.5V or 240v AC
  • Battery Type 4 x AA Alkaline
  • Static Power Consumption 0.5mW (DC)
  • Faucet Material Chrome-plated Brass
  • Faucet Weight 732g
  • Detection Range 190mm ± 15%
  • Water Pressure 0.05—0.6 MPa
  • Working Temperature 0-55°C

TYPICAL INSTALLATION

SPL-Washrooms-DL3100-Supreme-Delta-Basin-Mounted-Automatic-
Tap-2

INSTALLATION

SPL-Washrooms-DL3100-Supreme-Delta-Basin-Mounted-Automatic-
Tap-3

  1. Fit braided outlet pipe into faucet body then draw this and the sensor flex through the center hole in the basin.
  2. Use the fitted washer and fixing nut to fasten the faucet body.
  3. Drill two holes in the wall in relation to the holes in the control box mounting bracket. Insert the plastic expansion plugs into the holes and fix the bracket to the wall using the self-tapping screws.
  4. Mount the control box onto the bracket and fasten the screws.
  5. Insert the sensor plug into the sensor socket of the control box. Fasten the fixing nut.
  6. Mount the other end of the braided outlet pipe into the outlet on the control box.
  7. Connect the control box to the main water supply pipe with a braided pipe to the inlet on the control box.

POWER CONNECTION

NOTE: 240v Version ready to plug into power supply.SPL-Washrooms-DL3100
-Supreme-Delta-Basin-Mounted-Automatic-Tap-4

  1. Open the control box and take out the battery box.
  2. Insert 4 x AA batteries and close. If the box is difficult to close, squeeze the rubber sides to remove air.
  3. Place the battery box back into the control box.
  4. Connect the battery box and solenoid valve and do up the wires.
  5. Close the control box.

CHECKING POWER:
When the indicator light flashes every 2-3 seconds the batteries are running low and will need replacing. See Power Installation for more details. If the tap will not be used for a long period of time, remove the batteries to prevent corrosion.

FILTER CLEANING: Clean the filter after the first month of use, followed by a clean every six months. A reduced flow rate may also be a sign of a dirty filter.SPL-Washrooms-DL3100-Supreme-Delta-Basin-Mounted-Automatic-
Tap-6
To clean the filter:

  1. Close off the water supply
  2. Unscrew the nut at the end of the inlet pipe and take out the filter.
  3. Clean the filter with water and remount, then refasten the nut.

TROUBLESHOOTING

Issue Possible Reason Solution
No Water Flow Batteries run out Replace batteries
Dirt on sensor eye Clean sensor
Water stopped Reconnect water
Filter dirty Clean filter
Continuous washing over 1 minute Reuse after 10 seconds
Water Doesn’t Stop Flowing Dirt on sensor eye Clean sensor
Obstruction in detection zone Remove obstruction
Water drops on sensor eye Clean sensor
Reduced Flow Rate Filter dirty Clean filter

NOTE: For tempered water an additional mixing valve will be required.

WARRANTY

Your Supreme Delta Tap is fully guaranteed against defective materials and faulty workmanship commencing from the date of sale (according to SPL’s records), subject to it being installed and maintained in accordance with the manufacturer’s instructions. SPL (2021) Limited warrants that should any part of the tap fail within the given warranty period (12 – 24 months product dependant), it will be remedied by SPL. The tap should be returned to SPL (2021) Limited for all warranty claims. The cost of cartage will be payable by the customer. This warranty excludes:

  • Incorrect installation, or installation that does not specifically follow the installation guidelines supplied.
  • Failure to follow manufacturer’s maintenance instructions.
  • Damage/Failure resulting from:
    • the use of non-authorised parts
    • authorised parts not installed in accordance with the manufacturer’s instructions
    • accidental damage, negligent use, misuse, vandalism, neglect
    • damage caused either directly or indirectly by external sources – power outages, power surges, incorrect power supply, natural disaster, or insect infestation
    • water ingress caused by property maintenance or flooding
    • negligent cleaning practices (water ingress, harmful chemical etc)

The above includes consequential damage to any other goods, furnishings, or property.

  • Normal wear and tear and consumable parts (batteries).
  • This warranty does not displace any statutory warranty in relation to the tap but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the tap or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited.

Note: Our Warranty only extends to products purchased and installed in New Zealand. Batteries are covered by a 90 day, parts only, warranty.

SPL Limited
26 Gillies Street, Cambridge 3450
Ph: 07 823 5790
Fax: 07 823 5792
[email protected] | www.splwashrooms.co.nz

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SPL Washrooms User Manuals

Related Manuals