KONNER SOHNEN KS 3300i Inverter Generator Owner’s Manual
- June 13, 2024
- KONNER SOHNEN
Table of Contents
- KONNER SOHNEN KS 3300i Inverter Generator
- Product Information
- Product Usage Instructions
- INTRODUCTION
- MAIN OVERVIEW
- SPECIFICATIONS
- TERMS OF USE OF INVERTER GENERATOR
- GENERATOR OPERATION
- CHECK BEFORE GETTING STARTED
- GETTING STARTED
- CONNECTION OF GENERATOR WITH BUILT-IN ATS
- FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
- PARALLEL FUNCTION
- MAINTENANCE
- RECOMMENDED OILS
KONNER SOHNEN KS 3300i Inverter Generator
Product Information
The Inverter Generator is a portable power generator designed for various
applications. It comes in different models, including the KS 3300i, KS 4100iE,
KS 4100iEG, KS 8100iEG, KS 8100iE ATSR, KS 2000i S, KS 2000iG S, KS 4000iE S,
KS 4000iEG S, KS 4000iE S ATS, KS 6000iE S, and KS 6000iE S ATS. The generator
is equipped with a soundproof housing to minimize noise during operation.
It is important to note that the manufacturer reserves the right to make
alterations to the generators, which may not be reflected in the user manual.
The actual appearance of the product may vary from the pictures and photos
provided. Contact information for any issues can be found at the end of the
manual.
All data specified in the operation manual is up to date at the time of
publishing. For the current list of service centers, please refer to the
website of the official importer: uk.koenner-soehnen.com.
Failure to follow the recommendations marked with a warning sign may result in
serious injury or death of the operator or third parties.
Product Usage Instructions
Working Area:
- When installing the generator, pay attention to the capacity of electrical appliances and their starting current. The generator cannot run in overload conditions when starting consumers with an inrush current higher than the generator’s maximum output.
- Do not install the generator in residential buildings, premises connected to residential buildings by a common ventilation system, or other rooms from which exhaust gases may enter living premises. Exhaust gases contain poisonous carbon dioxide (CO2) and carbon monoxide (CO) gases, which are dangerous for life.
- Do not use the generator in rainy, snowy, or high humidity conditions. Avoid touching the generator with wet hands. Do not leave it in direct sunlight for a long time. It is recommended to store and use the generator under a canopy or in a well-ventilated area.
- Place the generator on a flat, hard surface away from flammable liquids/gases, maintaining a minimum distance of 1 meter. Install the generator at a distance of not less than 1 meter from the front control panel and not less than 50 cm on each side, including the upper part of the generator. The generator is equipped with dampers to reduce vibration and prevent damage to the installation surface.
- Avoid using the generator near flammable gases, liquids, or dust. The exhaust system of the generator gets very hot and may cause fire or explosion.
- Maintain cleanliness and good lighting in the work area to prevent injuries. Clutter and poor lighting can be hazardous.
- Ensure that unauthorized persons, children, or animals are not present in the working area. If necessary, fence off the working area. Use safety shoes and protective gloves when working with the generator.
Electrical Safety:
The generator generates electricity, so it is important to follow safety precautions to avoid electric shock. The specific safety measures depend on the application and system used:
- The generator should be used as an IT or TN system based on the application.
- Earthing and additional protective measures, such as insulation monitoring or protection against accidental contact (residual current device), must be provided based on the application and system used.
Please, read this manual carefully before use!
Inverter Generator
- KS 3300i
- KS 4100iE
- KS 4100iEG
- KS 8100iEG
- KS 8100iE ATSR
Inverter Generator in Soundproof Housing
- KS 2000i S
- KS 2000iG S
- KS 4000iE S
- KS 4000iEG S
- KS 4000iE S ATS
- KS 6000iE S
- KS 6000iE S ATS
INTRODUCTION
Thank you for your purchase of Könner & Söhnen® products. This manual contains
a brief descrip-tion of safety, use and debugging. We care about the
environment, therefore, we consider it expedient to save paper and leave in
print a short description of the most important sections. Please, read full
and the latest version of manual of the web-site of official importer of
Könner & Söhnen® products: uk.koenner-soehnen.com
Be sure to read the full version of the manual before getting started!
Manufacturer reserves the right to make alterations into the generators, which
may not be reflected in this manual. Pictures and photos of the product may
vary from its actual appearance. At the end of this manual, You may find
contact information which you are free to use in case of any issues
occurrence.
All data, specified in this operation manual is the most up to date for the
moment of its publishing. The current list of service centers you can find at
the website of official importer: uk.koenner-soehnen.com
ATTENTION – DANGER!
Failure to follow the recommendations marked with this sign may lead to serious injury or death of the operator or third parties.
IMPORTANT!
Useful information while operating the machine.
WORKING AREAWORKING AREA
- When installing the generator, pay attention to the ca-pacity of electrical appliances and their starting current, which may be several times higher than the rated cur-rent. The generator cannot run in overload conditions when starting consumers with an inrush current higher than the generator’s maximum output.
- As exhaust gases contain poisonous carbon dioxide (CO2) and carbon monoxide (CO) gases which are dangerous for life, it is strictly forbidden to install the generator in residential buildings, premises connected to residential buildings by a common ventilation system, other rooms from which exhaust gases may enter living premises.
- Do not use generator in the rain, snow and high humidity conditions, do not touch the generator with wet hands. It’s prohibited to leave it in direct sunlight in summer for a long time. It is recommended to store and use the generator under a canopy or in a well ventilated area.
- Place the generator on a flat, hard surface, away from flammable liquids/gases (at a minimum distance of 1 m). Install the generator at a distance of not less than 1 m from the front control panel and not less than 50 cm on each side, including the upper part of the generator. To reduce vibration during operation and to avoid damage to the surface, where the generator is installed, it is equipped with dampers.
- Please don’t use the generator near flammable gases, liquids or dust. When using the generator exhaust system gets very hot. This may cause fire or explosion of these materials.
- Be sure to follow cleanliness and good lighting in the work area. Clutter and poor lighting may cause an injury.
- Do not let the presence of unauthorized persons, children or animals when working with generator. If necessary, make sure to fencing the working area.
- Please use safety shoes and protective gloves when working with generator.
ELECTRICAL SAFETYELECTRICAL SAFETY
- The device generates electricity. Follow safety precautions to avoid electric shock.
- The generator should be used as an IT or TN system based on the application. Earthing and additional pro-tective measures such as insulation monitoring or pro-tection against accidental contact (residual current de-vice) must be provided based on the application and the system used.
- The generator produces electricity that may lead to an electric shock while neglecting compliance regu-lations.
- Könner & Söhnen generators were initially designed as an IT system with basic protection by insulation of hazardous live parts according to DIN VDE 0100-410. The generator housing is insulated from the cur-rent-carrying L and N conductors. The generator must be grounded in all cases, except for an IT system with an insulated neutral wire and bonding. A grounded IT system requires the use of an insulation monitoring device. Further details regarding the use of the generator in IT and TN systems can be found on our website or requested from our technical support.
- All connecting the generator to the network must be made by certified electrician in accordance with all electrical rules and regulations.
- It is not allowed to supply current from the electrical network to the generator when the power supply is restored.
- Do not allow moisture in the generator. The water inside the device increases the risk of an electric shock.
- In the high humidity level conditions generator exploit is prohibited. Keep the generator in a dry place only.
- Avoid direct contact with grounded surfaces (pipes, radiators, etc.).
- Be careful when working with power cables. Immediately replace it in case of damage, as damaged wire increases the risk of electric shock.
- Network connection should only be carried out by a qualified technician
- Connect the generator to the protective ground before operation.
- Do not connect or disconnect a generator to electricity consumers, which are placed in water on a wet or damp soil.
- Do not touch parts of the generator under voltage.
- Connect the generator to those customers only which meet the electrical characteristics and the rated power of the generator.
- Store all electrical equipment dry and clean. Wires with damaged or spoiled insulation should be re-placed. You should also replace worn, damaged or rusty contacts.
IMPORTANT!
It is forbidden to connect to the generator devices which can generate current pulses and direct energy towards the generator (voltage stabilizers, devices with electronic brakes, on-grid and hybrid inverters, etc.).
The generator and power consumers form a closed system, with elements affecting each other. This system is physically different from the public network since it is significantly affected by factors such as unbalanced phase load and non-linear current consumption by power consumers that can cause damage to the gener-ator and power consumers connected to it.
IMPORTANT!
Using device for other purposes deprives the right for free warranty.
PERSONAL SAFETYPERSONAL SAFETY
- Be careful. Do not operate the generator, if you are tired, under the influence of drugs or alcohol. Inatten-tion may cause a serious injury.
- Avoid inadvertent start. Make sure to set the switch to Off when you turn off the generator.
Non compliance to these requirements may result in generator combustion or explosion, as well as in electric wiring ignition inside the structure.
- To avoid inhaling exhaust gas, the generator does not have to work in conditions of poor ventilation. Exhaust gas contains poisonous carbon monoxide.
- Make sure no outsider objects are on the generator when it is turned on. Using device for other purposes deprives the right for free warranty. It is not allowed to sit or stand on the generator.
- Always keep a stable position and balance when starting the generator.
- Do not overload the generator, use it only for the purpose.
PRECAUTIONS WHEN WORKING WITH PETROL GENERATORPRECAUTIONS WHEN WORKING WITH PETROL GENERATOR
- Do not start the generator operation upon presence of electric load. Disconnect the load before you stop the engine.
- Generator installation is to be performed at minimum 1 meter safety distance from flammable objects. All explosive and flammable materials or substances are to be kept away from the generator, for its engine produces heat during operation.
- Do not refuel the running generator.
- It is forbidden to smoke during generator refuelling operations.
- Only unleaded petrol is recommended for the generator. After filling the tank, all excessive fuel spillage are to be removed from the surface. It is forbidden to use kerosene or other fuel types.
- Observe the fuel tank refilling. Do not allow overfilling.
- It is forbidden to touch the exhaust system during the generator start and in process of its running.
- It is forbidden to run the generator in cases when its exposure to rain, snow and possibility of soakage exist.
- Before running the generator, it is necessary to define the place and means of its emergency stop.
- Fuel contaminates the land and groundwater. Do not allow the leaking petrol from the tank!
PRECAUTIONS WHEN WORKING WITH HYBRID GENERATORPRECAUTIONS WHEN WORKING WITH HYBRID GENERATOR
- Könner & Söhnen® duel fuel generators can use the fol-lowing types of gas as fuel when working on gas: pro-pane, propane-butane and butane (butane can be used only in the warm season. When the ambient temperature is above +10 0C).
- Do not start the generator operation upon presence of electric load! Disconnect the load before you stop the engine.
- You are allowed to connect all the power consuming supplies only after generator got warmed up. If you start generator with appliances being connected the engine may work unstable due to the fuel remains in the carburetor.
- Disconnect the load before you stop the engine, disconnect all the connected devices first, then close the gas valve, then turn off the engine. After that set the starter switch to OFF position and turn off the gas supply valve.
- Before usage make sure, that all the hoses are connected properly.
- In case of gas leakage, stop the gas flow from the source to generator and switch off all the electric appli-ances connected as soon as possible.
- For stopping gas powered engine: disconnect all the connected devices first, then close the gas valve, then turn off the engine. After that set the starter switch to OFF position and turn off the gas supply valve.
ATTENTION – DANGER!
- Do not allow sparks near gas powered generator during its work.
- The gas cylinder valve must not be closed when the gen-erator is not running. The generator must not be operat-ed on gas in basements.
- Pay attention! Usage of petrol together with liquefied gas is forbidden! When you operate using petrol, you must stop LPG supply. When you operate generator using LPG – you must stop petrol supply.
MAIN OVERVIEW
- Manual starter
- Frame
- Fuel tank cap
- Control panel
- Oil-depth gage
- LED display
- 12V DC fuse
- Reset button
- Oil level indicator
- Voltage indicator
- Overload indicator
- Earthing bolt
- 2×13А AC outlets
- 12V/8.3A DC outlet
- Economy mode switch (ЕCОN)
- Engine switch
ММODELS ODELS KS 4100KS 4100iiE, KS 4100E, KS 4100iiEG, KS 8100EG, KS 8100iiEG,EG, KS 8100 KS 8100iiE ATSRE ATSR
- Fuel tank cap
- Fuel level indicator
- Control panel
- Carrying handles
- Manual starter (only for models KS 4100iE, KS 4100iEG)
- Transport wheels
- Oil-depth gage
- Multifunctional engine switch
- Oil level indicator
- Overload indicator
- Voltage indicator
- Fuel indicator (for DUAL-FUEL models)
- Reset button
- 12V DC fuse
- Economy mode switch (ЕCОN)
- LED display
- Generator parallel outputs (except for KS 8100 model modifications)
- Earthing bolt
- 2×16А AC outlets (for KS 8100 model modifications, sockets 113A, 132A)
- 12V/8.3A DC outlet
- 2 USB-Outputs
- Model KS 8100iE ATSR use a control panel with an ATS (Automatic Transfer Switch) output.
MODELS KS 2000i S, KS 2000iG S
- Fuel tank cap air vent
- Carrying handles
- Control panel
- Manual starter
- Air choke (for model KS 2000i S). Fuel switch for model KS 2000iG S. Model KS 2000iG S has an air choke located on its control panel.
- Maintenance cover (on the other side of the generator)
- 2 USB-Outputs (for model KS 2000i S)
- Economy mode switch (ЕCОN)
- LED display
- 1×13А AC outlet
- Earthing bolt
- Reset button
- Generator parallel outputs
- For KS 2000iG S, the control panel has an air choke and a fuel switch. Use the start button instead of the multifunction engine switch.
MODELS KS 4000iE S, KS 4000iEG S, KS 4000iE S ATS
- Fuel tank cap
- Carrying handles
- Control panel
- Manual starter
- Transport wheels
- Maintenance cover
- Engine switch (multifunction engine switch for model KS 4000iEG S)
MODELS KS 4000iE S, KS 4000iEG S
- 2 USB-Outputs (for model KS 4000iEG S)
- Economy mode switch (ЕCОN)
- LED display (multifunctional LED display for model KS 4000iE S)
- 12V DC fuse
- 2×13А AC outlets
- Earthing bolt
- Generator parallel outputs
- Reset button
- 12V/8A DC outlet10. ATS input button
- Oil level indicator, overload indicator, voltage indicator, ATS operation indicator, ATS operation errors
- Circuit breaker
- Mains input AC 230V
MODELS KS 6000iE S, KS 6000iE S ATS
- Carrying handle
- Fuel tank cap air vent
- Control panel
- Manual starter
- Transport wheels
- Maintenance cover
- Multifunction engine switch
MODELS KS 6000iE S /MODELS KS 6000iE S ATS
- 12V DC fuse
- Multifunctional LED display
- 2 USB-Outputs
- 1×13А AC outlet
- Economy mode switch (ЕCОN)
- Reset button
- Generator parallel outputs
- 1×32А AC outlet
- Earthing bolt
- 16V AC fuse
- ATS input
- 12V/8.3A DC outlet
- ATS input button
- Oil level indicator, overload indicator, voltage indicator, ATS operation indicator, ATS operation errors
- Circuit breaker
- LED display
- Mains input AC 230V
IMPORTANT!
Manufacturer reserves the right to make changes and/or improvements in design,
components set and technical attributes without notice and without incurring
obligation. The pictures in this manual are schematical and may not match the
parameters of original product.
In addition to the components shown in the figure of a petrol generator, a
generator with a hybrid system (LPG/ petrol) is equipped with a hose for
supplying LPG to the generator.
- Built-in reducer.
- Gas cylinder connection hose (1.5 m).
Connect the LPG hose to the LPG input
SPECIFICATIONS
Model | KS 2000i S | KS 2000iG S |
---|---|---|
Voltage, V | 230 | |
Maximum power, W | 2000 | 2000* |
Nominal power, W | 1800 | 1800* |
Frequency, Hz | 50 | |
Current, A (max.) | 8.7 | 8.7 |
Outlets | 1*13A | 1*13A |
Engine start | manual | manual |
Fuel tank volume, l | 5 | 5 |
Working time at 50% load (petrol fuel), h** | 6.25 | 6.25 |
LED display | voltage, frequency, working hours | |
Noise level Lpa (7m)/Lwa, dB | 62/87 | 63/88 |
Output 12V, A | – | – |
USB- Outputs | 5V/1A, 5V/2.1A | – |
Engine model | KS 100i | KS 100i |
Engine volume, cm 3 | 79.7 | 79.7 |
Engine type | petrol, 4 stroke cycle engine | LPG/petrol 4 stroke |
cycle engine
Engine power, hp| 2.5| 2.5
Generator parallel socket| +| +
Crankcase volume, l| 0,4| 0,4
Power factor, cos φ| 1| 1
ATS input| –| –
Dimensions (LxWxH), mm| 555х335х540| 700х335х540
Lithium battery, Ah| –| –
Net weight, kg| 19| 19
Protection class| IP23M
Nominal voltage tolerance – max. 5%
- LPG operation reduces generator power by 10%.
- Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con-dition of the generator.
- To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.
- The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications.
- In the event of deviations from these environmental indicators, the generator performance may vary.
- Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to extend its service life.
Model | KS 4000iE S | KS 4000iEG S | KS 4000iE S ATS |
---|---|---|---|
Voltage, V | 230 | ||
Maximum power, W | 4000 | 4000* | 4000 |
Nominal power, W | 3500 | 3500* | 3500 |
Frequency, Hz | 50 | ||
Current, A (max.) | 17.4 | 17.4 | 17.4 |
Outlets | 2*13A | 2*13A | 2*13A |
Engine start | manual/electric | manual/electric | manual/electric/auto |
Fuel tank volume, l | 12 | 12 | 12 |
Working time at 50% load (petrol fuel), h** | 7.8 | 7.8 | 7.8 |
LED display | multifunctional*** | voltage, frequency, working hours | |
Noise level Lpa (7m)/Lwa, dB | 70/95 | 71/96 | 66/91 |
Output 12V, A | 12V/8.3A | 12V/8.3A | – |
USB- Outputs | – | 5V/1A, 5V/2.1A | – |
Engine model | KS 240i | KS 240i | KS 240i |
Engine volume, cm 3 | 223 | 223 | 223 |
Engine type | petrol, 4 stroke cycle engine | LPG/petrol 4 stroke |
cycle engine
| petrol, 4 stroke cycle engine
Engine power, hp| 7.5| 7.5| 7.5
Generator parallel socket| +| +| –
Crankcase volume, l| 0.6| 0.6| 0.6
Power factor, cos φ| 1| 1| 1
ATS input| +| –| Built-in ATS
Dimensions (LxWxH), mm| 630х475х570| 775х475х570| 630х475х570
Lithium battery, Ah| 1.6| 1.6| 1.6
Net weight, kg| 40| 40| 40
Protection class| IP23M
Nominal voltage tolerance – max. 5%
- LPG operation reduces generator power by 10%.
- Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con-dition of the generator.
- Multifunctional LED-display: load, fuel level, voltage, frequency, working hours; overload indicator, voltage indicator, oil level indicator.
- To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.
- The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications.
- In the event of deviations from these environmental indicators, the generator performance may vary.
- Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to extend its service life.
Model | KS 6000iE S | KS 6000iE S ATS |
---|---|---|
Voltage, V | 230 | |
Maximum power, W | 5500 | 5500 |
Nominal power, W | 5000 | 5000 |
Frequency, Hz | 50 | |
Current, A (max.) | 23.9 | 23.9 |
Outlets | 113A, 132A | 1*32A |
Engine start | manual/electric | manual/electric/auto |
Fuel tank volume, l | 11 | 11 |
Working time at 50% load (petrol fuel), h** | 7 | 7 |
LED display | multifunctional*** | voltage, frequency, working hours |
Noise level Lpa (7m)/Lwa, dB | 70/95 | 70/95 |
Output 12V, A | 12V/8.3A | – |
USB- Outputs | 5V/1A, 5V/2.1A | – |
Engine model | KS 240i | KS 240i |
Engine volume, cm 3 | 223 | 223 |
Engine type | petrol, 4 stroke cycle engine | petrol, 4 stroke cycle |
engine
Engine power, hp| 7.5| 7.5
Generator parallel socket| +| –
Crankcase volume, l| 0,7| 0,7
Power factor, cos φ| 1| 1
ATS input| +| Built-in ATS
Dimensions (LxWxH), mm| 640х425х600
Lithium battery, Ah| 1.6| 1.6
Net weight, kg| 39.5| 40
Protection class| IP23M
Nominal voltage tolerance – max. 5%
- LPG operation reduces generator power by 10%.
- Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con-dition of the generator.
- Multifunctional LED-display: load, fuel level, voltage, frequency, working hours; overload indicator, voltage indicator, oil level indicator.
- To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.
- The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications.
- In the event of deviations from these environmental indicators, the generator performance may vary.
- Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to extend its service life.
Model | KS 3300i | KS 4100iE | KS 4100iEG |
---|---|---|---|
Voltage, V | 230 | ||
Maximum power, W | 3300 | 4000 | 4000* |
Nominal power, W | 3000 | 3600 | 3600* |
Frequency, Hz | 50 | ||
Current, A (max.) | 14.4 | 17.4 | 17.4 |
Outlets | 2*13A | 2*13A | 2*13A |
Engine start | manual | manual/electric | manual/electric |
Fuel tank volume, l | 7 | 12.5 | 12.5 |
Working time at 50% load (petrol fuel), h** | 7 | 8.1 | 8.1 |
LED display | voltage, frequency, working hours | ||
Noise level Lpa (7m)/Lwa, dB | 71/96 | 70/95 | 71/96 |
Output 12V, A | 12V/8.3A | – | – |
USB- Outputs | – | 5V/1A, 5V/2.1A | 5V/1A, 5V/2.1A |
Engine model | KS 210i | KS 240i | KS 240i |
Engine volume, cm 3 | 208 | 223 | 223 |
Engine type | petrol, 4 stroke cycle engine | LPG/petrol 4 stroke |
cycle engine
Engine power, hp| 5.5| 7.5| 7.5
Generator parallel socket| –| –| +
Crankcase volume, l| 0.6| 0.6| 0.6
Power factor, cos φ| 1| 1| 1
ATS input| –| +| –
Dimensions (LxWxH), mm| 450x380x460| 605х420х425| 685х420х430
Lithium battery, Ah| –| 1.6| 1.6
Net weight, kg| 25.5| 36.7| 38
Protection class| IP23M
Nominal voltage tolerance – max. 5%
- LPG operation reduces generator power by 10%.
- Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con-dition of the generator.
- To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.
- The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications.
- In the event of deviations from these environmental indicators, the generator performance may vary.
- Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to extend its service life.
Model | KS 8100iEG | KS 8100iE ATSR |
---|---|---|
Voltage, V | 230 | |
Maximum power, W | 8500* | 8500 |
Nominal power, W | 8000* | 8000 |
Frequency, Hz | 50 | |
Current, A (max.) | 36.9 | 36.9 |
Outlets | 113A, 132A | 113A, 132A |
Engine start | electric | electric |
Fuel tank volume, l | 20 | 20 |
Working time at 50% load (petrol fuel), h** | 6 | 6 |
LED display | voltage, frequency, working hours | |
Noise level Lpa (7m)/Lwa, dB | 70/95 | 70/95 |
Output 12V, A | 12V/8.3A | 12V/8.3A |
USB- Outputs | 5V/1A, 5V/2.1A | 5V/1A, 5V/2.1A |
Engine model | KS 480i | KS 480i |
Engine volume, cm 3 | 458 | 458 |
Engine type | LPG/petrol 4 stroke |
cycle engine
| petrol, 4 stroke cycle engine
Engine power, hp| 16| 16
Generator parallel socket| –| –
Crankcase volume, l| 1.1| 1.1
Power factor, cos φ| 1| 1
ATS input| –| +
Dimensions (LxWxH), mm| 740х520х580| 725х505х555
Lithium battery, Ah| 1.6| 1.6
Net weight, kg| 68| 68
Protection class| IP23M
Nominal voltage tolerance – max. 5%
- LPG operation reduces generator power by 10%.
- Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical con-dition of the generator.
- To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.
- The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications.
- In the event of deviations from these environmental indicators, the generator performance may vary.
- Please note that continuous loads exceeding 80% of the generator’s rated power are not recommended in order to extend its service life.
TERMS OF USE OF INVERTER GENERATOR
It is recommended to ground the generator before operating it for the first time. Before starting the device, remember that the total power of the connected power consumers should not exceed the nominal power of the generator.
- Könner & Söhnen generators were initially designed as an IT system with basic protection by insulation of hazardous live parts according to DIN VDE 0100-410. The generator housing is insulated from the current-carrying L and N conductors. The generator must be grounded in all cases, except for an IT system with an insulated neutral wire and bonding. A grounded IT system requires the use of an insulation monitoring device.
- Make sure that the control panel, the blinds and the underside of the inverter are well cooled and protected against the ingress of small solids, dirt, and water. Im-proper operation of the cooler can cause damage to the motor, inverter or alternator.
GENERATOR OPERATION
-
OIL LEVEL INDICATOROIL LEVEL INDICATOR
When the oil level falls below the level required for operation, the oil level indicator lights up, and then the engine stops automatically. The engine will not start until oil is added. -
AC INDICATORAC INDICATOR
When the generator is running and producing electricity, the AC indicator light is on. -
DC FUSEDC FUSE
The DC protector automatically switches to “OFF” when the current of the operating electrical device is higher than the rated current. To use this equipment again, turn on the DC fuse again by pressing the “ON” button.
If the DC fuse turns off, reduce the load of the connected electrical device. If the DC protector turns off again, stop operation and contact your nearest Könner & Söhnen service center.
OVERLOAD INDICATOROVERLOAD INDICATOR
The overload indicator lights up when the generator is overloaded, the
inverter control unit overheats or the AC output voltage rises.
If the overload indicator goes on, the engine will continue to operate, but
the generator will no longer produce electricity. In this case, you must
perform the following steps:
- Turn off all connected electrical appliances and stop the engine.
- Reduce the total power of the connected devices until the nominal power of the generator is reached.
- Check if the vent grid is clogged. Remove excess dirt or debris, if any.
- After checking, start the engine.
IMPORTANT!
The overload indicator may light up within several sec-onds after start-up or when connecting electrical devices requiring a high starting current, such as a compressor or voltage indicator. However, this is not a malfunction.
FUEL TANK CAP AIR VENT (FOR MODEL KS 2000FUEL TANK CAP AIR VENT (FOR MODEL
KS 2000ii S) S)
The fuel cap is equipped with a vent for air supply to the fuel tank. When the
engine is running, the vent must be in the “ON” position (OPEN). This will
allow fuel to enter the carburetor for engine operation. After the generator
stops, allow it to cool down and close the air vent on the fuel cap. When the
generator is not in use, close the vent to the “OFF” position.
EARTHING BOLTEARTHING BOLT
In all cases, except for an IT system with an insulated neutral wire and
bonding, the generator earthing bolt must be connected to the grounding
circuit with a flexible copper conductor with a cross-sectional area of at
least 6 mm2.
CHECK BEFORE GETTING STARTED
CHECKING THE FUEL LEVEL
- Unscrew the fuel cap and check the fuel level in the tank.
- Fill the fuel tank to the fuel filter level.
- Tighten the fuel cap securely.
- For models in a housing of inverter generator, open the air intake vent on the fuel cap. Recommended fuel: Recommended fuel: unleaded fuel.
Fuel tank volume:Fuel tank volume: see specifications table.
Wipe up spilled fuel immediately with a clean, dry, soft cloth, as the fuel
may harm painted surfaces or plastic parts.
Use only unleaded petrol. Using leaded petrol can cause serious damage to the
inside of the engine.
CHECKING THE OIL LEVELCHECKING THE OIL LEVEL
The generator is transported free of motor oil. Do not start the engine until
it is filled with sufficient amount of motor oil.
- Open the service cover (fig.1).
- Unscrew the oil dipstick (fig. 2) and wipe it out with a clean cloth.
- Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification chart.
- Insert the dipstick without screwing it in.
- Check the oil level by a mark on the oil dipstick.
- Add oil if its level is below the mark on the oil dipstick.
- Screw on the dipstick.
Recommended motor oil: Recommended motor oil: SAE 10W30, SAE 10W40. Recommended motor oil grade: Recommended motor oil grade: API Service SG type or higher. Motor oil quantity: Motor oil quantity: see specifications table.
GETTING STARTED
- Before starting the engine, Before starting the engine, make sure that the rated power of power consumers matches with the power of generator. Do not exceed the nominal power of the generator. Do not connect any devices before Do not connect any devices before youyou start the engine!start the engine!
- Do not change the controller settings in terms of the amount of fuel or speed governor (this adjustment was made at the factory). Otherwise, this may result in changes in the engine operation or its failure.
- In the power supply mode, the generator should operate no longer than 1 minute in the range from nominal to maximum power.
- Standby generators should not run continuously (e.g. by adding fuel to the tank or connecting a large fuel tank) or longer than recommended: 4-6 hours for LPG/petrol or petrol generators (depending on load).
This material is for informational purposes only and does not constitute a manual for installing the equipment or connecting it to the mains, but we strongly recommend that you read the instructions below. Equipment connection must always be carried out by a certified electrician responsible for the installation and electrical connection of the equipment according to local laws and regulations. The manufacturer assumes no lia-bility for improper connection of the equipment or for any material or physical damage that may result from improper installation, connection or operation of the equipment.
COMMISSIONING
- Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification chart.
- Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
- Check fuel level.
- Check the air filter for correct installation
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
- During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal (operating) power of the device.
- After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after operation to ensure quick and complete oil draining.
- Check and clean the air filter, fuel filter and spark plug.
Before starting the generator, connect the ground wire to the ground terminal.
The generator is shipped with terminals disconnected to prevent battery self- discharge during storage. To connect the battery terminals of the KS 4000iE S generator, proceed as follows:
- Open the service cover
- Connect the terminals ensuring the correct polarity (“+” to “+”, “-” to “-”).
ENGINE START
Useful tip: If the engine stalls or does not start, turn the engine switch to the “ON” position, and then pull the manual starter. If the oil level indicator flickers for several seconds, add oil and restart the engine.
Each time you start the generator, be sure to check oil and fuel level
FOR MODELS KS 3300i, KS 4100iE, KS 4000iE S, KS 6000iE S, KS 8100iE ATSR, KS 6000iE S ATS
-
Check oil level.
-
Check fuel level.
-
Turn the Multifunctional engine switch to the “START” position (fоr Model KS 4000iE S, KS 6000iE S to the “RUN” position).
-
Open the vent on the fuel cap to the “ON” position (for model KS 6000iE S, KS 6000iE S ATS, KS 4000iE S).
-
For manual start (models KS 3300i, KS 4100iE, KS 4000iE S, KS 6000iE S, KS 6000iE S ATS), pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the manual starter by hand, do not release it abruptly.
For electric start, press the red button on the multifunctional engine switch (fig. 3) -
After starting the engine, turn the Multifunctional engine switch to the “RUN” position (fig. 3).
FOR MODEL KS 2000I S
- Check oil level.
- Check fuel level.
- Open the vent on the fuel cap to the “ON” position (fig. 4).
- Turn the air choke control knob to the “START” position (fig. 5).
- Pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the manual starter by hand, do not release it abruptly.
- Turn the air choke control knob to the “RUN” position
Useful tip: to ensure long-term operation of the generator engine, it is important to observe the following tips:
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator immediately. Allow the generator to run idle for 1-2 minutes so that it cools down.
- Do not connect two or more devices at a time. The start-up of many devices requires high power. Devices should be connected one at a time according to their power rating. Do not connect any power consumers within the first 2 minutes after the generator has been started.
RUNNING GENERATOR ON LPG (KS 4100iEG, KS 8100iEG, KS 2000iG S, KS 4000iEG S)
- Check oil level.
- The inverter generators KS 4100iEG, KS 8100iEG, KS 4000iEG S use smart fuel switching system. In order to use LPG as fuel you need to connect a hose to the corresponding connector and open the valve on the gas cylinder. The solenoid valve will automatically shut off the petrol supply from the petrol tank
- Connect the LPG hose to the LPG input (connect hose end A to the LPG input, as shown in Fig. 6).
- Connect the hose end with the reducer to the gas cylinder (connect hose end B to the gas cylinder, as shown in Fig. 6).
- Open the gas valve on the cylinder, making sure that no gas is leaking.
- Press the pressure relief valve on the reducer 2-3 times (only for model KS 2000i S).
- Turn the Multifunctional engine switch to the “START” position.
- For manual start, pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the manual starter by hand, do not release it abruptly. For electric start, press the red button on the multifunctional engine switch (fig. 3)
- After starting the engine, turn the Multifunctional engine switch to the “RUN” position (fig. 3). 10. When using for the first time, fill the gas line with gas by turning the key (pressing start button) to the “OFF” position and slowly pull the starter handle to the full cord length 2 to 3 times (except for models KS 8100, which do not have a manual start).
For model KS 2000iG S: Close the air choke (pull the air choke handle) if the generator is not warmed up. Set the PETROL FUEL SWITCH to the “OFF” position, set the engine start to the “ON” position, grasp the starter handle and slowly pull it until resistance is felt. Pull the starter cord to the full length with a sharp movement. The generator will start. If this is not the case, repeat this action. Slowly turn the manual starter by hand, do not release it abruptly. Open the air choke by pushing the air choke handle.
IMPORTANT!
- Disconnect the load from the generator before changing fuel. The ECONOMY MODE switch must be in the “OFF” position.
- For model KS 2000iG S: It is recommended to stop the generator before switching from petrol to LPG! Petrol remains in the carburetor make it difficult to start the engine on LPG. Let the generator run out of petrol until it stops. To do this, close the fuel valve with the generator running and wait until the generator stops completely. Then start the generator on LPG. You can also drain the remaining petrol from the carburetor before starting the generator on LPG.
To drain petrol from the carburetor, turn off the fuel valve and wait until the generator has cooled down sufficiently. For open frame models, place a drip pan under the carburetor and loosen the drain screw on the carburetor (Fig. 7). Make sure that no fuel leaks onto the generator. Tighten up the screw again. Start the generator on LPG according to the instructions mentioned above For all modifications of models KS 2000i, loosen the 4 screws on the side panel. Loosen drain screw C on the carburetor and let the remaining fuel drain through pipe D into the dedicated drip pan. Avoid petrol leaks. Tighten up the screw. Install back the generator housing cover. Start the generator on LPG.
TO START LPG/PETROL GENERATOR ON PETROL MODE (KS 4100iEG, KS 2000iG S, KS 4000iEG S, KS 8100iEG)
- Close the gas valve on the cylinder.
- Open the vent on the fuel cap to the “ON”
- Set the fuel switch to “ON” and close the air choke on the control panel (for model KS 2000iG S).
- Start the engine by hand or electric start.
- Open the air choke (for model KS 2000iG S).
Fuel can be changed without stopping the generator. When switching from petrol
to LPG operation, the generator may be unstable during the first 2-3 minutes
and the low voltage protection may trip. If the red indicator (overload
indicator) lights up in 2-3 minutes after running the generator on LPG when it
is running stable, press the AC Reset BUTTON on a panel of generator to
restore voltage supply
If during usage of LPG, need to switch to petrol, you only need to disconnect
the LPG supply, generator will automatically switch to petrol оperation,
without other operations.
For models with electric start, check if the battery is charged. If necessary,
recharge the battery with a dedicated charger for lithium-ion batteries or
start the generator with a manual start and allow it to run idle while it is
recharging
CONNECTION OF GENERATOR WITH BUILT-IN ATS
Connection diagrams for generators with built-in ATS can be found in the full electronic version of the manual. This material is for informational purposes only and does not constitute a manual for installing the equipment or connecting it to the mains, but we strongly recommend that you read the instructions below. Equipment connection must always be carried out by a certified electrician responsible for the installation and electrical connection of the equipment according to local laws and regulations. The manufacturer assumes no liability for improper connection of the equipment or for any material or physical damage that may result from improper installation, connection or operation of the equipment
ATTENTION – DANGER
Risk of electric shock! Network connection should only be carried out by a
qualified technician.
FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
It is forbidden to start the generator with the ECONOMY MODE ON. Economy mode should be turned on only after starting the generator and only with a low load. Failure to comply with this requirement may result in generator failure and void warranty repair.
ECON FUNCTIONECON FUNCTION
- Start the engine.
- Set the ECON switch to “ON”.
- Plug the device into an AC outlet.
- Make sure the AC indicator light is on.
- Turn on the electrical device.
The ECON switch must be set to “OFF” to increase engine speed to nominal. When connecting multiple power consumers to the generator, be sure to first connect the one with the highest starting current, and the device with the lowest starting current should be connected last.
“ON” MODE“ON” MODE
When the ECON switch is in the “ON” position, the control unit monitors the
engine speed, reducing it commensurate with the connected load. If the engine
speed is not enough to generate electricity to provide the load, the control
unit will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
“OFF” MODE“OFF” MODE
The ECON switch must be set back to “OFF” when using electrical devices
requiring a high starting current, such as a compressor or submersible pump.
The ECON switch must be set back to “OFF” when using electrical devices requiring a high starting current, such as a compressor or submersible pump.
PARALLEL FUNCTION
The total output power of the generators can be increased by connecting two inverter generators together using the Parallel Unit KS PU1 from Könner & Söhnen. Parallel connection of two generators ensures total rated output power of these generators. When the generators are connected in parallel, the power loss is 0.2 kW of the total rated power that can be obtained (suitable for all models of inverter generators from Könner & Söhnen, except for KS 8100iEG, KS 8100iE ATSR).
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR
Do not stop the generator with the devices turned on. This may disable the generator or devices connected to it!
TO STOP THE ENGINE, PROCEED AS FOLLOWS (EXCEPT MODELS KS 2000I S, KS 2000IG S):
- Turn off all devices.
- Allow the generator to run idle for approx. 1-2 minutes.
- Turn the Multifunctional engine switch to the “OFF” position (Fig. 9).
- Close the gas valve
- Unplug the devices.
- After the generator stops, allow it to cool down and close the air vent on the fuel cap (set to OFF, as shown in Fig. 8, when switching off petrol operation).
MODELS KS 2000i S, KS 2000iG S
- Turn off all devices.
- Allow the generator to run idle for approx. 1-2 minutes.
- Set the engine switch to the “OFF” position.
- Turn the air choke control knob to the “OFF” position (Fig. 10), for dual fuel models – move the fuel switch to the OFF position/ close LPG supply valve.
- Allow the generator to cool down.
- Unplug the devices.
- After the generator stops, allow it to cool down and close the air vent on the fuel cap (set to OFF, as shown in Fig. 8, for models KS 2000i S, KS 2000iG S – when switching off petrol operation).
CHARGING AN EXTERNAL 12 V BATTERY
- Start the engine.
- Connect the red wire to the positive (+) terminal of the battery.
- Connect the black wire to the negative (-) terminal of the battery.
- Connect the wire to a 12V/8A DC socket on the control panel of the generator.
- To start charging the battery, set ECON to “OFF”.
- Turn the 12 V DC fuse to the “ON” position.
Inverter generators from Könner & Söhnen are equipped with lithium batteries with an operating voltage similar to conventional lead-acid batteries. When the generator is running, the battery is charged automatically. If it is necessary to charge the battery with an external device, we recommend using the KS-B2A charger or the charger for charging lead-acid motorcycle batteries with a nominal voltage of 12V with a charge current of not more than 2A.
IMPORTANT!
- Make sure the ECON mode is off while the battery is being charged.
- Be sure to connect the charger’s red wire to the plus (+) terminal of the battery and the black wire to the minus (-) terminal of the battery. Do not swap the terminals.
- Connect the charger to the battery terminals securely so that they are not disconnected due to motor vibrations or other actions.
- The 12 V socket can only be used as a backup source for recharging batteries and shall not be deemed as a full-featured battery charger.
- The DC protector turns off automatically if the current is higher than the rated current while the battery is being charged. To restore battery charging, turn on the DC fuse by pressing the “ON” button.
ATTENTION – DANGER Never smoke or interrupt battery connections to the generator while the battery is being charged
MAINTENANCE
Contact us to get technical support and find out the address of the nearest service center: support.uk@dimaxgroup.de
TECHNICAL MAINTENANCE WORKS
- If the generator often operates at high temperature or high load, the oil should be replaced every 25 operating hours.
- If the engine often runs in dusty or other harsh conditions, clean the air filter every 10 operating hours.
- If you missed the maintenance time, perform it as soon as possible to save the generator engine.
IMPORTANT The manufacturer shall not be liable for any damage caused by failure to perform maintenance work.
RECOMMENDED OILS
Use oils designed for four-stroke cycle vehicle engines SAE10W-30, SAE10W-40. Motor oils with other viscosity levels, may be used only if the average air temperature in your region does not exceed the limits of the temperature range, specified in the table. Upon oil level decrease it is necessary to add the required quantity in order to provide the correct generator operation. It is necessary to check the oil levels according to technical maintanance schedule. Further details can be found in the full version of the manual on our website.
TO DRAIN ENGINE OIL, PERFORM THE FOLLOWING ACTIONS:
- Please drain the oil while the engine is warm. This provides a quick and complete oil drain.
- Wear protective gloves to avoid getting oil on the skin.
- Remove the cover of generator (fig. 11).
- Place a drain oil holding tank under the engine (fig. 12).
- Turn the drain cap, located in the engine under the oil-depth gage cap, by means of spanner (fig. 13).
- Wait till the oil drains.
- Replace the drain cap and tighten it well.
- Close the maintenance cover (fig. 11).
AIR FILTER TECHNICAL MAINTENANCE
Air filter cleaning is to be performed each 50 hours of the generator operation (every 10 hours in unusually dusty conditions).
CLEANING THE FILTER:
- Open the clips on the upper cap of the air filter.
- Remove the sponge filtering element.
- Remove all dirt deposits inside the hollow case of the air filter.
- Thoroughly wash the filtering element in warmsoapy water.
- Dry the sponge filter.
- Dry filtering element is to be moistened by motor oil and excess oil is to be squeezed out.
SPARK PLUGS TECHNICAL MAINTENANCE
Spark plug has to be intact, without soot deposits and to have a correct gap.
SPARK PLUG VERIFICATION:
- Remove the cap from the spark plug.
- Remove the spark plug by means of a corresponding spanner.
- Examine the spark plug. If is is shattered – it is necessary to replace it. Recommended replacement spark plugs – F7TC.
- Measure the gap. It has to be within range 0.7-0.8 mm.
- In case of repeated use, the spark plug has to be cleaned by means of a metal brush. After that – set the correct gap.
DAMPER AND FLAME ARRESTER MAINTENANCE
The engine and damper will get very hot after the generator has been started. Do not touch the engine or damper with any part of your body or clothing during inspection or repair until they have cooled down. Remove the screws and then pull the protective cover towards you. Loosen the bolts and remove the cover, screen and flame arrester of the damper. Descale the screen and flame arrester of the damper with a wire brush.Inspect the screen and flame arrester of the damper. Replace them if they are damaged. Replace the flame arrester. Replace the screen and cover of the damper. Replace the cover and tighten the screws
IMPORTANT! Match the protrusion of the flame arrester to the hole in the pipe damper
- Remove the fuel tank cap and fuel filter.
- Clean the filter with petrol.
- Wipe the filter and replace it.
- Replace the fuel tank cap.
Make sure that the fuel tank cap is tight.
BATTERY USE
The generator battery is not subject to service. Low temperatures may lower the capacity of the lithium-ion battery and may cause an unstable generator start
STORAGE
IMPORTANT! The generator must be stored and transported with a closed vent at all times
Storage room has to be dry and free from dust deposits. Storage room also has to be locked away from children and animals. It is recommended to store and use the generator at temperature of -20°С to +40°С. Avoid direct sunlight, rain on the generator. When using and storing hybrid generator, gas tank should be kept indoors at temperatures below +10°С. If the temperature is lower, gas will evaporate. Information on long-term storage and transportation can be found in the full version of the manual.
BATTERY AND GENERATOR DISPOSAL
To prevent environment damage generator and battery should be separated from ordinary waste. Please recycle them in the safest way, passing it to special place for disposal.
POSSIBLE FAILURES AND SOLUTIONS
Typical failures | Possible reason | Solution |
---|
Engine does not starting
| Engine starting swinch set to OFF position| Set the engine starting switch
to ON
Fuel valve set to off position| Turn the valve to ON position
Air flap is opened| Shut the air flap
No fuel| Add fuel
Low-quality or dirty fuel is in engine| Change the fuel
Sparking plug smoked or corrupted distance between contacts is not nominal
| Clean or replace the plug; Set proper distance between contacts
Low engine power / heavy starting
| Dirt in fuel tank| Clean the fuel tank
Dirt in the air filter| Clean the air filter
Water in a fuel tank/ carburetor; carbure- tor is jammed| Empty the fuel tank,
carburetor
Distance between contacts of a sparking plug is not nominal| Set proper
distance between contacts
Engine overheated
| Cooling fins are dirty| Clean the cooling fins
Air filter is dirty| Clean the air filter
No voltage while working engine
| Circuit breaker is active| Turn on the cricuit breaker
Connected cables are corrupted| Check the cables; if using extension
cord, change it
Plugged device failure| Try to connect other devices
Connected devices are not working while generator is running
| Generator is overloaded| Unplug some devices to reduce load
Short circuit occured in one of the devices connected| Unplug that device to
restore the stability of a system
Air filter is dirty| Clean the air filter
Repetitions of an engine are lower than nominal| Contact the service center
AVERAGE POWER USAGE
Device | Average power usage, W |
---|---|
Iron | 500-1100 |
Air hair dryer | 450-1200 |
Coffee machine | 800-1500 |
Electric cooking stove | 800-1800 |
Toaster | 600-1500 |
Air heater | 1000-2000 |
Vacuum cleaner | 400-1000 |
Radio | 50-250 |
BBQ Grill electric device | 1200-2300 |
Oven | 1000-2000 |
Refrigerator | 100-150 |
TV set | 100-400 |
Hammer drill | 600-1400 |
Drill | 400-800 |
Freezer | 100-400 |
Grinding machine | 300-1100 |
Circular saw | 750-1600 |
Angle grinder | 650-2200 |
Electro jigsaw | 250-700 |
Electro planer | 400-1000 |
Compressor | 750-3000 |
Water pump | 750-3900 |
Electric sawing machine | 1800-4000 |
Electric lawn | 750-3000 |
Electric powered engines | 550-5000 |
Electric fan | 750-1700 |
High pressure machine | 2000-4000 |
Air conditioner | 1000-5000 |
EC Declaration of Conformity
- Manufacturer: DIMAX INTERNATIONAL GmbH
- Address: Flinger Broich 203, 40235 Duesseldorf, Germany
- Product: Inverter generators “Kanner & Sohnen”
- Type / Model: KS 2000i S, KS 2000iG S, KS 3300i, KS 4000iE S, KS 4000iEG S,
- KS 4000iE S ATS, KS 41 OOiE, KS 41 OOiEG, KS 6000iE S, KS 6000iE S ATS,
- KS 8100iE ATSR, KS 8100iEG ATSR, KS 8100iE, KS 8100iEG.The following products have been tested by us with the listed standards and found in compliance with the European Community Machinery Directive 2006/42/EC, Electromagnetic compatibility Directive (EMC) 2014/30/EC, Noise Directive 2000/14/EC.
The statement is based on a single evaluation of above mentioned products. t c:loes not imply an assessment of the w 0le productiom and does not permit the.,u e of the tes lab. logo. The manufacturer should ensure that all product in series produc;t1on are in con armity with the product sample de ;a ied in is report. The applicant shou , hold th wnole technical report at disposal of the compet int all the right.
Applied EC Directives
- 2006/42/EC Machinery Di ective
- 2014/30/EC Electromagl’)etic compatibility Directive (EMC)
- 2000/14/EC Noise DirecUve( ameo,de..d · 2005/88/EC)
- (EU) 2016/1628 Non-Road mobile machimery emissions
- (EU)2017 /654 amended by (EU) 2018/989
- (EU)2017 /655 amended l:>y (EU? 20t-8/9S:7
- (EU)2017 /656 amended fuy (EU 2018/988
- EN ISO 8528-13:2016 EN 55012:2007+A 1
- N 61000-6-1 :2007 00/14/EC
- 55/88/EC
- EN 1§0 3 44:1995
Gasoline engines KS 1 00i, KS 21 0i, KS 240i, KS 480i correspond to European Emission Standard Euro 5 (STAGE V). This is confirmed by EU TYPE-APPROVAL CERTIFICATE issued by department of transport of Luxembourg. Technical service responsible for carrying out the test -TOV Rheinland Luxemburg GmbH. Date of issue 30/10/2018
2000/14/EC_2005/88/EC Annex VI
For model KS 4000iE S ATS, KS4100iE, KS 4100iEG, KS 6000iE S, KS 6000iE S ATS,
KS Bl00iE, KS Bl0OiEG, KS Bl00iE ATSR, KS Bl00iEG ATSR
- Noise measured Lw,= 95 dB (A),
- For model KS 2000i S, KS 2000iG S Noise measured Lw,= 87dB (A)
- For model KS 4000iE S, KS 4000iEG S Noise measured Lw,= 91dB (A)
- For model KS 3300i Noise measured Lw,= 96dB (A)
Issued Date: Place of issue: General director:
2022-08-12 Dusseldorf Fomin P. p
We DIMAX INTERNATIONAL GmbH hereby declare that specified above conforms covering European Parliament and Council Directives, 2006/42/EC of 17 May 2006 Machinery Directive, Electromagnetic compatibility Directive (EMC) 2014/30/EC of 26 February 2014, Noise Directive 2000/14/EC of 8 May 2000. The CE mark above can be used under the responsibility of manufacturer. After completion of an EC declaration of Conformity and compliance with all relevant EC directives.
CONTACTS
Official representative in the United Kingdom: Innovation trade LLC,
info.uk@dimaxgroup.de Technical
supportTechnical support
support.uk@dimaxgroup.de
Deutschland:
DIMAX International GmbH Flinger Broich 203 -FortunaPark- 40235 Düsseldorf,
Deutschland
www.koenner-soehnen.com
Ihre BestellungenIhre Bestellungen
orders@dimaxgroup.de
Kundendienst, technische FragenKundendienst, technische Fragen und
Unterstützungund Unterstützung
support@dimaxgroup.de
Garantie, Reparatur und ServiceGarantie, Reparatur und Service
service@dimaxgroup.de
SonstigesSonstiges
info@dimaxgroup.de
Polska:
DIMAX International
Poland Sp.z o.o.
Polska, Warczawska, 306B 05-082 Stare Babice,
info.pl@dimaxgroup.de
References
- UK Koenner-Soehnen
- Könner & Söhnen Stromerzeuger ᐉ Generatoren k&s | Könner & Söhnen Notstromaggregat und Gartentechnik
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>