H RMANN RSE2-433 Handsender User Manual
- June 13, 2024
- H RMANN
Table of Contents
TR20L001-A RE / 08.2010
RSE2-433 Handsender
TR20L001-A RE / 08.2010
Important information
Your hand transmitter works with a rolling code which changes with every transmitting action. For this reason, the hand transmitter must be programmed on each receiver to be activated using the desired hand transmitter button (see receiver instructions).
Safety Instructions
WARNING
Danger of injury during door travel
Persons may be injured by door travel if the hand transmitter is actuated.
- Ensure that neither persons nor objects are located within the door’s range of travel.
- Make sure that the hand transmitters are kept away from children and cab only be used by people who have been instructed on how the remote-control door functions!
- If the door has only one safety feature, only operate the hand transmitter if you are within sight of the door!
- Only drive or pass through remote control door systems if the door is in the OPEN end-of-travel position!
- Please note that unintended door cycles may occur if a hand transmitter button is accidentally pressed (e.g. if stored in a pocket/handbag).
ATTENTION
Functional disturbances caused by environmental conditions
These conditions can impair function!
Protect the hand transmitter from the following conditions:
- Direct sunlight (perm. ambient temperature: -20°C to +60°C)
- Moisture
- Dust
NOTE:
Local conditions may affect the range of the radio system.
Each time the button on the hand transmitter is pressed, the LED O a emits a
signal. If the LED lights up, the trans- mitter is operating.
If the LED flashes when the button is pressed, transmission is still going on
but the battery is so low that it urgently needs replacing.
If the LED fails to respond, check whether the battery is correctly inserted
(see Fig. 1). Replace the battery if necessary.
Figures 1
Putting into operation/Changing the battery
- Open the hand transmitter as shown.
- Remove the spent battery and insert the new one, making sure to pole correctly.
- Re-close the hand transmitter.
Figures 2
Teaching in the hand transmitter on the operator/ receiver
The hand transmitter works with a rolling code that changes with each sending
procedure. For this reason, the hand transmitter must be taught in with the
desired hand transmitter button on each receiver that is to be controlled.
- To do this, briefly press the P button on the operator cover or the P button on the receiver. The red LED will begin to flash, signalising that the desired hand transmitter button can be programmed.
- Press and hold the hand transmitter button until the red LED flashes quickly; then release the hand transmitter button.
- Press the hand transmitter button again within 15 seconds, until the red LED begins flashing very rapidly; then release the hand transmitter button. Once the rapid flashing stops, the desired hand transmitter button has been successfully taught in and the red LED will remain lit.
- After teaching in the hand transmitter or extending the radio system, check the functions.
Technical Details
Type: Hand transmitters RSC 2
Status display: LED (red)
Frequency: 433 MHz
Coding: Rolling code
Power supply: Battery, 3 volt lithium CR 2025 (Ø20 x 2.5 mm)
EC Manufacturer’s Declaration of Conformity
Manufacturer: Hörmann KG Verkaufsgesellschaft
Upheider Weg 94-98
D-33803 Steinhagen
Product: Hand transmitters for door operators and accessories
Product description: RSC 2
Product identification: RSC2-433
Device type: RSE2-433
Frequency: 433 MHz
CE label: 0359
Intended for use in all EU countries, Norway, Switzerland and others.
The products described above comply, in their design and form, with the
pertinent underlying requirements of the guidelines detailed below in the
versions sold on the market.
This declaration loses validity if changes are made to the product which we
have not approved.
Pertinent provisions with which the product complies Compliance of the
products described above with the regulations laid down for the guidelines
according to article 3 of the R&TTE Guidelines 1999/5/EC is demonstrated by
the products’ adherence to the following standards:
EN 300 220-1
EN 300 220-2
EN 301 489-1
EN 301 489-3
Steinhagen, 25/03/2010
ppa. Axel Becker
Managing Director
TR20L001-A RE / 08.2010
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>